| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoCMC |
| Instrument Type | Vertical |
| Base Temperature | 2.3 K |
| Vibration Stability | High |
| Dimensions | 446 × 266 × 641 mm³ |
| Cooling Method | Air-Cooled |
| Refrigeration Power | 50 mW @ 2.8 K |
| Cold Head Diameter | 45 mm |
| Electrical Feedthroughs | Standard 6, Optional 12 |
| Max. Electrical Power Consumption | 1.4 kW |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY800xs |
| Instrument Type | Vertical |
| Temperature Range | 3.8 K to 300 K |
| External Dimensions | 17 in × 28 in (432 mm × 711 mm) |
| Cooling Method | Closed-cycle helium refrigeration, helium-free operation |
| Vibration Performance | Sub-microradian angular stability, <5 nm RMS vertical displacement below 10 Hz |
| Vacuum Enclosure | User-customizable, optically accessible, multi-port design |
| Integration Height | Compatible with standard optical table height (762 mm ± 10 mm) |
| Electrical Feedthroughs | 36 DC leads included |
| Optical Compatibility | Designed for low-temperature achromatic objectives (e.g., attoLFT series), ≥12 mm working distance, AR-coated viewports (250–1100 nm) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY800 |
| Instrument Type | Upright |
| Temperature Range | 3.8 K to 320 K |
| Temperature Stability | <15 mK |
| Vibration Level | <5 nm peak-to-peak (vertical, 1500 Hz bandwidth) |
| Sample Chamber Diameter | 75 mm |
| Base Pressure | <5×10⁻⁶ mbar |
| Leak Rate | <5×10⁻⁹ mbar·L/s |
| Cool-down Time (to 5 K) | <4.5 h |
| Cooling Power | >170 mW @ 5 K |
| Compressor Power | 3 kW |
| Cooling Method | Closed-cycle, helium-free |
| Dimensions (Optical Table Mounting) | 900 mm × 1800 mm × 305 mm (height of vibration isolation legs: 597 mm) |
| Brand | attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoDRY800 / attoDRY1000 / attoDRY1100 / attoDRY2100 |
| Cooling Principle | Pulse-tube cryocooler |
| Base Temperature | 3.8 K (attoDRY800), 4 K (attoDRY1000/1100), 1.5–1.8 K (attoDRY2100) |
| Temperature Range | 1.5–320 K (model-dependent) |
| Temperature Stability | < ±5 mK (attoDRY2100), < ±10 mK (attoDRY1000/1100), < ±15 mK (attoDRY800) |
| Vertical Vibration Amplitude (Z-axis) | < 0.15 nm (attoDRY1000/1100/2100), < 5 nm peak-to-peak (attoDRY800) |
| Sample Chamber Diameter | 49.7 mm (attoDRY1000/1100/2100), 75 mm (attoDRY800) |
| Magnetic Field Options | Up to 9 T (superconducting), vector magnet configurations available |
| Optical Access | Integrated optical vacuum chamber with high-NA low-temperature objectives (NA ≥ 0.8) |
| Control Interface | Touchscreen-based automated temperature & field control (attoDRY1100/2100), manual control (attoDRY800/1000) |
| Refrigeration Power | >5 mW @ 5 K, >1000 mW @ 4.2 K (attoDRY1000/1100/2100) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | atto CMC |
| Instrument Type | Vertical |
| Base Temperature | 2.3 K |
| Vibration Stability | High |
| Dimensions | 446 × 266 × 641 mm³ |
| Cooling Method | Air-Cooled |
| Refrigeration Power | 50 mW @ 2.8 K |
| Cold Head Diameter | 45 mm |
| Electrical Feedthroughs | Standard 6, Optional 12 |
| Max. Electrical Power Consumption | 1.4 kW |
| IGLU Compressor Integration | Yes |
| Rack-Mountable | 19-inch compatible |
| Control | Remote via Ethernet/RS232 |
| Automation Level | Fully Automated Cool-Down & Operation |