| Brand | SiriusXT Ltd. |
|---|---|
| Origin | Ireland |
| Model | SXT-100 |
| Resolution | 40 nm (3D half-pitch ~30 nm) |
| Light Source | Compact laboratory soft X-ray source (λ = 2.3–4.4 nm, “water window”) |
| Field of View | 30 µm (900× magnification) |
| Acquisition Time | <2 hours per 100 projection images |
| Sample Thickness Capacity | Up to 15 µm hydrated specimens |
| Sample Handling | Carbon-supported copper grids (±60° tilt) or ultra-thin glass capillaries (±90° rotation) |
| Fluorescence Channels | 5-channel (DAPI, GFP, RFP, Cy5, Cy7) |
| Compliance | Designed for GLP-compliant correlative workflows |
| compatible with cryo-preparation protocols per ISO 21530 | 2021 and ASTM E3186-22 |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 336 |
| Sensor Inputs | 4 (expandable to 8 with Scan Option) |
| Control Outputs | 4 (2 high-power, 2 low-power) |
| Max Heating Power | 150 W (100 W + 50 W) |
| Temperature Range | 0.3 K to 1505 K |
| PID Control | Digital, Auto-Tuning & Zone-Based |
| Supported Sensors | Diodes, RTDs (Pt100, Pt1000, Carbon-Glass, Cernox®, Rox™), Thermocouples (DT-470, DT-670, E, K, T, AuFe/Cr), Capacitance (with option card) |
| Interface | Ethernet, USB, IEEE-488 (GPIB) |
| Analog Output | ±10 V, 16-bit, 0.3 mV RMS noise |
| Display | 240 × 64 pixel graphical LCD |
| Compliance | GLP/GMP-ready architecture, supports audit trail via software logging |
| Brand | iotaSciences |
|---|---|
| Origin | United Kingdom |
| Model | isoPick |
| Type | Fully Automated |
| Sorting Speed | High-throughput |
| Core Technology | GRID Microfluidic Patterning (Patent WO2019197373A1) |
| Chamber Density | 256 single-cell cavities per 6 cm dish |
| Dispense Volume | Nanoliter-scale precision |
| Imaging | Integrated high-resolution optical microscopy |
| Sample Transfer Compatibility | Direct transfer to PCR tubes or 96-well plates |
| Cell Viability | Optimized for minimal mechanical stress |
| Brand | Novilet |
|---|---|
| Origin | Poland |
| Model | ERI TM 600 |
| Imaging Modality | Electron Paramagnetic Resonance (EPR) Imaging |
| Sample Type | Live small animals (mouse, rat) |
| Spin Probe Required | Yes |
| Field Strength Range | 0.01–500 G (CW), 0.01–50 G (rapid scan) |
| Operating Frequency | 575 MHz |
| RF Power Output | Up to 500 mW |
| Modulation Amplitude | Up to 50 G |
| Modulation Frequency | 1 kHz |
| Magnetic Field Resolution | 10 mG |
| Field Stability | ±20 mG |
| Field Noise | ≤5 mG RMS |
| Gradient Strength | 13 G/cm |
| Magnet Bore Diameter | 34 mm |
| Imaging Volume | 20 cm³ |
| 3D Acquisition Time | As low as 4.5 s (225 projections) |
| SNR (OXO63, 25 g mouse, 100 ms) | 112 |
| Digital Resolution | 16-bit |
| Q-Factor | >800 |
| Temperature-Controlled Animal Holder | Integrated |
| Anesthesia-Compatible Gas Exchange System | Included |
| Stereotactic Mouse Brain Fixation | Standard |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 350 |
| Input Channels | 4 (expandable to 8 with Scan Option) |
| Sensor Compatibility | Cernox®, Rox™, DT-470, DT-670, PT-100/1000, carbon-glass, germanium, silicon diodes, thermocouples (with option cards), capacitive sensors |
| Measurement Range | 10 mK to 1000 K (sensor-dependent) |
| Excitation Current | As low as 10 nA for Cernox® |
| Noise Performance | Ultra-low-noise input circuitry optimized for ≤100 mK operation |
| Control Outputs | 4 independent PID-controlled outputs — Output 1: 75 W (25 Ω load), Output 2: 1 W (100 Ω load), Outputs 3 & 4: ±10 V analog (1 W max, 100 mA) |
| PID Auto-tuning | Per-loop, real-time adjustment |
| Current Reversal | Eliminates thermoelectric offset in resistive sensors |
| Compliance | CE certified |
| Interface | RS-232, USB, Ethernet (LXI-compliant) |
| Display | 240 × 64 pixel graphical LCD (8 × 40 characters), LED backlit |
| Data Logging | Local buffer + remote streaming at up to 10 Hz per active channel |
| Brand | NanoView Biosciences |
|---|---|
| Origin | USA |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Catalog Variants | EV-TETRA-C, EV-TETRA-P, EV-TETRA-M2, EV-TETRA-C-CAR, EV-TETRA-P-CAR, EV-TC-FLEX, EV-TP-FLEX, EV-TC-FLEX-CAR, EV-TP-FLEX-CAR, EV-TM-FLEX, EV-TM-FLEX-CAR, EV-FLEX-2, EV-FLEX-2-CAR, EV-CTETRA-1/2/3, EV-CTETRA-1/2/3-CAR, EV-CUST-1–6, EV-CUST-1–6-CAR |
| Sample Volume | 35 µL |
| Replicates | Triplicate |
| Capture Antibodies | anti-CD9, anti-CD63, anti-CD81, IgG isotype control |
| Detection Fluorophores | CD9 (Blue), CD81 (Green), CD63 (Red) |
| Detection Principle | Single-Particle Interferometric Reflectance Imaging Sensing (SP-IRIS) |
| Minimum Detectable Size | ≥50 nm |
| Content Detection Capability | Yes (with membrane-permeabilizing reagent) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 335 |
| Temperature Range | 0.3 K to 1505 K |
| Sensor Inputs | 2 standard (expandable to 4 with optional thermocouple card) |
| Control Outputs | 2 independent PID channels |
| Heater Power | 75 W total (configurable as 50 W + 25 W or 75 W + 1 W) |
| Interface | Ethernet, USB, IEEE-488 (GPIB) |
| Analog Output | ±10 V |
| Compliance | GLP/GMP-ready with audit-trail-capable logging via software |
| Brand | Telight |
|---|---|
| Origin | France |
| Model | Q-Phase |
| Type | Coherence-Controlled Holographic Microscope (CCHM) for Quantitative Phase Imaging (QPI) |
| Imaging Modes | QPI, Fluorescence, DIC, Brightfield, High-Pass Filtered Phase |
| Automation | Fully Automated Time-Lapse, Multi-Position, Multi-Channel, Z-Stack Acquisition & Segmentation |
| Detection Principle | Laser Interferometric Holography with Spatial Coherence Control |
| Cell Compatibility | Live, Unfixed, Unstained, 3D-Matrix Embedded Cells |
| Data Output | Quantitative Phase Maps (nm), Dry Mass (pg), Morphometric Parameters (Area, Perimeter, Thickness, Asymmetry), Temporal Dynamics (ms–hr scale) |
| Regulatory Context | Designed for GLP-compliant research |
| Brand | iotaSciences |
|---|---|
| Origin | United Kingdom |
| Model | isoCell |
| Type | Fully Automated |
| Sorting Throughput | 256 cells per 10 minutes |
| Total Sortable Cells per Run | 256 |
| Sample Processing Capacity | 256 single cells per cycle |
| Programmable Protocols | 1 |
| Sample Preparation | Direct sorting from untreated single-cell suspension without pre-enrichment or staining |
| Brand | Nanoanalytics |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CellZscope |
| Price Range | USD 68,000 – 136,000 |
| Brand | INTERHERENCE |
|---|---|
| Origin | Germany |
| Model | VAHEAT |
| Temperature Range | RT–200 °C |
| Temperature Stability | ±0.01 °C (RMS) |
| Power Consumption | Standard Version < 2500 mW |
| Heating Rate | Up to 100 °C/s (local), 40 °C/s (in liquid) |
| Compatible Microscopy Modes | Widefield, Confocal, TIRF, iSCAT, STED, SIM, PALM, STORM, PAINT, AFM |
| Brand | Viventis Microscopy |
|---|---|
| Origin | Switzerland |
| Model | LS2 |
| Light Sheet Technology | Dual-side illumination with scanned Gaussian light sheet |
| Imaging Resolution | 406 nm (16× objective), 260 nm (25× objective) |
| Field of View | 900 µm (16×), 596 µm (25×) |
| Maximum Sample Size | >50 mm |
| Stage Travel Range | 50 mm |
| Positioning Repeatability (±) | <100 nm in XYZ |
| Laser Wavelengths | 405 nm, 488 nm, 561 nm, 638 nm |
| Objectives | Dual 25× water-immersion, NA 1.1 |
| Camera | Dual high-sensitivity sCMOS sensors, QE ≥80%, acquisition speed >30 fps |
| Illumination | Dual-side illumination |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe MN180 |
| Imaging Modes | PALM, STORM, smFRET, PAINT, SPT |
| Illumination Configurations | Epi, TIRF, HILO |
| Lateral Resolution | 20 nm (XY), Axial Resolution: 50 nm (Z) |
| Field of View | 150 × 150 µm² |
| Compatibility | Modular integration via C-mount on inverted fluorescence microscopes |
| Software Control | Fully automated acquisition for TIRF/PALM/STORM/SPT/smFRET |
| Compatible Systems | Confocal, Spinning Disk, Widefield, SIM, STED |
| Dye Compatibility | Atto 488, WGA-AF®488, AF®532, CF®532, Cy3b, AF®555, AF®594, CF®555, AF®568, CF®568, Cy5, MemBrite™ 568, TMR, AF®647, CF®647, AF®680, CF®680, MemBrite™ 640, Actin-stain 670, SiR647 |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe 360 |
| Resolution | 20 nm |
| Field of View | 200 × 200 µm² |
| Category | Super-Resolution Microscope (SMLM) |
| Technique | Single-Molecule Localization Microscopy (SMLM) with 3D axial localization |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe M90 |
| Scan Field of View | 150 µm × 150 µm (with 100× objective) |
| Imaging Speed | up to 330 fps at 512 × 512 pixels |
| Objectives Supported | 60×, 100× |
| Multicolor Capability | Simultaneous 4-channel imaging |
| TIRF Angle Calibration Accuracy | <1.2% error |
| Illumination Modes | TIRF / HILO / Epi (software-switchable) |
| Depth Imaging | Z-stack compatible |
| Dichroic Stability | Precision-engineered cubes for long-term chromatic alignment |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe MN360 |
| Technology | Structured Illumination Microscopy (SIM) & Single-Molecule Localization Microscopy (SMLM) |
| Resolution | 15 nm (x, y, z) |
| Field of View | 200 × 200 µm² |
| Imaging Modes | PALM, STORM, PAINT, smFRET, SPT |
| Illumination Modes | Epi, TIRF, HILO |
| Depth Imaging Capability | 1.2 µm per acquisition (up to 10 µm total depth) |
| Multicolor Capacity | Up to 4 simultaneous channels |
| Drift Correction | Real-time hardware-based |
| Live-Cell Compatibility | Yes |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible metadata logging |
| Brand | Planelight |
|---|---|
| Origin | Spain |
| Model | QLS-scope |
| Light Sheet Technology | Uniform, tunable-thickness light sheet (1 µm) |
| Field of View (FOV) | 0.2–8 mm |
| Maximum Sample Dimensions | 25 × 25 × 25 mm |
| Objective Lenses | 1×, 2×, 7.5×, 10×, 20× (water immersion), 40× (water immersion), motorized variable magnification |
| Imaging Modes | Single-angle, dual-angle, quad-angle, SPOT (500-angle rotational acquisition), Z-Motor scanning |
| Acquisition Speed | 7–10 ms per plane |
| Autofocus | Real-time focal plane correction during acquisition |
| Sample Chamber | Motorized, adaptable for varying sample sizes and compatible with CO₂ incubators |
| Imaging Media Compatibility | Aqueous and organic clearing agents |
| Required Imaging Medium Volume | 20 mL |
| Vibration-Free Sample Handling | Active stabilization for soft or delicate specimens |
| Brand | Cytosurge |
|---|---|
| Origin | Switzerland |
| Model | FluidFM OMNIUM |
| Type | Fully Automated |
| Category | Life Science Instrumentation / Cell Analysis / Single-Cell Manipulation Platform |