- All
- Favorite
- Popular
- Most rated
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-300 |
| Temperature Range | 2 K to 500 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (Typical Operating Pressure: ~10⁻⁵ Torr) |
| Cooling Medium | Liquid Helium (down to 2 K) or Liquid Nitrogen (down to 77 K) |
| Cool-down Time to 5 K | ≤15 min |
| System Mass (excl. Transfer Lines) | ~4.6 kg |
| LN₂ Consumption @ 80 K | 0.1 L/h |
| LHe Consumption @ 5 K | 0.6 L/h |
| Initial LHe Fill (RT → Base Temp) | 0.4 L |
| Vacuum Requirement (Initial) | ~10⁻³ Torr |
| Optical Access | Standard Integrated Windows |
| Mounting Orientation | Omnidirectional |
| Compatibility | RGC Helium Recirculation Cryocooler (Helium-Free Operation) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP Series |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-FTIR / ST-FTIR / VPF-FTIR |
| Quotation | Upon Request |
| Temperature Range | 2 K to 500 K (STVP/ST), 65 K to 500 K (VPF) |
| Cooling Method | Liquid Helium (STVP/ST), Liquid Nitrogen (VPF) |
| Sample Environment | Flowing Vapor (STVP), High Vacuum (ST, VPF) |
| Temperature Stability | ±50 mK |
| Cool-down Time | ≤15 min to 5 K (STVP/ST), ≤15 min to 77 K (VPF) |
| Optical Access | Four Configurable Windows |
| Window Material Options | CaF₂, BaF₂, Sapphire, Polyethylene, Mylar, Silicon, Germanium (covering Far-IR to X-ray) |
| Translation Stage Travel | 51 mm |
| Sample Holder | 3-Position Rotatable Mount |
| Mounting Interface | Standard ISO-KF or CF Flange |
| Compatibility | Commercial FTIR Spectrometers (Bruker, Thermo Fisher, PerkinElmer, Nicolet) |
| Optional Accessories | Electrical Feedthroughs (DC, BNC, SMA, Triaxial), Custom Sample Stages (4-Probe, Plug-in, Optical), Vacuum-Compatible Thermometry (Cernox®, RuO₂, Diode) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-300S |
| Cooling Type | Closed-cycle cryocooler |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Typical Temperature Stability | ±50 mK |
| Cool-down Time | 1.5–2.5 h |
| Vibration Level | <40 nm (RMS) |
| Optical Window | Yes |
| Window Diameter | 38 mm to 85 mm |
| Cold Head Mounting | Flexible (user-configurable orientation) |
| Recommended Cryocooler Maintenance Interval | 13,000 hours |
| Approximate Height | 71–99 cm |
| Approximate Weight | 17–30 kg |
| Compliance | Designed for integration into ISO/IEC 17025-compliant labs and GLP/GMP-adjacent research environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-100 |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Typical Cool-Down Time | 1–2 h |
| Vibration Level | Not Specified |
| Optical Window | Yes |
| Window Diameter | 83–85 mm |
| Cold Head Mounting | Flexible (User-Defined Orientation) |
| Recommended Compressor Maintenance Interval | 13,000 h |
| Approximate Height | 56–84 cm |
| Approximate Weight | 16–29 kg |
| Brand | Metis |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CryoPulse |
| Operating Temperature Range | 4 K to 300 K |
| Maximum Pulsed Magnetic Field | ≥ 80 T |
| Pulse Duration | Up to 20 ms (configurable) |
| Magnet Bore Diameter | 20–54 mm |
| Field Rise Time (dB/dt) | As low as 6.2 ms |
| Energy Storage Capacity | ≥ 32 kJ (modular CDM-X capacitor bank, 4 kJ/module) |
| Voltage Rating | 3000 V |
| Data Acquisition | 16-bit, 1 MS/s, synchronized multi-channel (B-field, time, current, sample signal) |
| Cryogenic Compatibility | Liquid nitrogen (77 K) and liquid helium (4.2 K) Dewars |
| Sample Access | Replaceable cold finger (17 mm ID, 15 mm clear bore) |
| Compliance | Designed for GLP-compliant operation |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer | Quantum Design, Inc. |
| Type | Import |
| Model | Optistat DN, Optistat DN-V, Optistat CF, Optistat CF-V, Optistat Dry TLEX, Optistat Dry BLV |
| Cryogen Options | Liquid nitrogen, liquid helium, or cryogen-free (Cryofree™) |
| Base Temperature | 2.2 K–77.2 K (model-dependent) |
| Minimum Temperature | <3 K (Dry BLV/TLEX), 2.3 K (CF-V), 77.2 K (DN/DN-V) |
| Maximum Temperature | 300 K–600 K (model-dependent) |
| Sample Environment | Exchange gas or high vacuum |
| Sample Space | 20 mm Ø to 40 × 50 mm |
| Temperature Stability | ±0.1 K over 10 min |
| Cooling Time | 10 min (CF-V) to <6 hrs (Dry BLV) |
| Vibration | <0.1 µm RMS (CF-V/CF) to <10 µm RMS (Dry models, with mitigation) |
| Controller Interface | Mercury iTC intelligent temperature controller (optional), touchscreen, 24-bit resolution, 0.1 mK stability, up to 80 W/channel heating |
| Optical Windows | User-replaceable Spectrosil B (UV–mid-IR), CaF₂, ZnSe, TPX, and custom options for UV–THz coverage |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | RGC |
| Cooling Medium | Helium (gaseous & liquefied) |
| Operating Principle | Closed-loop cryogenic recirculation with pulse-tube or GM-based cold head |
| Compatible Cryostats | Lake Shore ST-100, ST-300, ST-400, ST-500, STVP series |
| Base Temperature (with ST-500) | ≤3.3 K (RGC4-20), ≤3.5 K (RGC4-15), ≤3.9 K (RGC4-12), ≤4.3 K (RGC4-10) |
| Cooling Power @ 5 K | up to 280 mW (RGC4-20) |
| Vibration Level (ST-500 + RGC) | <50 nm RMS (1–100 Hz) |
| Sample Exchange | Cold-insertion compatible (no warm-up required) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer | Quantum Design, Inc. |
| Type | Imported |
| Model | HelioxVT |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-XG |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 325 K |
| Sample Environment | High Vacuum |
| Vibration Level | <40 nm (RMS) |
| Typical Temperature Stability | ±50 mK |
| Cool-Down Time | 2–3 h |
| Optical Window Diameter | 83–85 mm |
| Approximate Height | 66–94 cm |
| Approximate Weight | 17–30 kg |
| Recommended Cold Head Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | CCS-400H |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | 5 K to 800 K |
| Sample Environment | High-Vacuum Chamber |
| Typical Temperature Stability | ±50 mK |
| Cooling Time (to base temperature) | 2–2.5 h |
| Optical Window Diameter | 83–85 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Vibration Level | <40 nm (RMS, at sample stage) |
| Cold Head Mounting | Flexible (top-mount configuration standard) |
| Weight | 16–30 kg |
| Height | 66–94 cm |
| Compliance | Designed for ASTM E220, ISO/IEC 17025-compliant lab environments |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Integra |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ST Series |
| Pricing | Available Upon Request |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Quantum Design Oxford Superconducting Magnet and Cryogenic System |
| Instrument Type | Vertical |
| Temperature Range | < 1.5 K to 600 K |
| Magnetic Field Options | 6–14 T (including 6-1-1 T hybrid) |
| Helium-3 Insert Temperature Range | 300 mK – 300 K |
| Sample Space Diameter | up to 50 mm (variable by configuration) |
| Temperature Stability | ±50 mK (standard cryostat), ±3 mK @ 350 mK (HelioxVT), ±0.1 K (optical systems) |
| Cooling Time (RT → base T) | <2 hr (<2 K, dry system), ~90 min (to 5 K, optical magnet), <10 min (Microstat LN₂), <150 min (<3 K, dry refrigeration) |
| Refrigeration Method | Cryogen-free (pulse tube or GM), liquid helium (open-cycle), or liquid nitrogen (open-cycle) |
| Software | oi.DECS (open architecture, Python API, multi-instrument control) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-900 |
| Quotation | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4 K to 800 K (2 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas |
| Sample Types | Solid, Liquid, Powder |
| Sample Exchange Time | <10 min |
| Rotatable Sample Stage | Yes |
| Cool-down Time | 3–4 h |
| Cold Head Position | Top-Mounted |
| Optical Window | Standard (CCS-900), Optional (CCS-900-T) |
| Approximate Height | 114 cm (CCS-900), 114–168 cm (CCS-900-T) |
| Approximate Weight | 48 kg (CCS-900), 45–50 kg (CCS-900-T) |
| Sample Chamber Diameter | 38.1 mm |
| Customizable Chamber Dimensions | 28.6 mm, 38.1 mm, 60.3 mm |
| Window Block Diameter | 95.3 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Microstat |
| Price | Upon Request |
| Cooling Method | Vacuum-cryogen-cooled (Liquid Nitrogen or Liquid Helium) |
| Temperature Range | 2.2 K to 500 K |
| Sample Environment | High-vacuum chamber |
| Sample Space (diameter × height) | 20 × 2 mm (N), 20 × 5 mm (He, HiRes) |
| Working Distance | Adjustable from 2.2 mm to 24.5 mm |
| Temperature Stability | ±0.1 K (10 min, Microstat He/HiRes), ±0.5 K (10 min, Microstat N) |
| Cool-down Time | <10 min (N, He), <15 min (HiRes) |
| Cryogen Consumption | <0.5 L/h (He, ~4.2 K), <0.45 L/h (He, HiRes), ~4.2 L/h (LN₂, 77 K) |
| Vibration | <0.1 µm (N, He), <20 nm (HiRes) |
| Lateral Sample Drift | <1 µm/h (N, He), <150 nm/h (HiRes) |
| Electrical Feedthroughs | 4 DC (N), 10 DC (He, HiRes) |
| Controller | Mercury iTC Intelligent Temperature Controller (optional, touch-enabled, 0.1 mK stability, 80 W/channel heating, 24-bit ADC) |
| Brand | Montana Instruments |
|---|---|
| Origin | USA |
| Model | XP Series |
| Temperature Range | 1.7 K – 350 K |
| Temperature Stability | <2 mK (peak-to-peak at 1.7 K), <200 mK (1.7–15 K), <50 mK (15–350 K) |
| Vibration Stability | <20 nm (peak-to-peak, horizontal at sample stage) |
| Base Cooling Power | >20 mW at 1.7 K |
| Sample Space | Φ92 mm × 92 mm |
| Optical Access | 3 standard windows (2 side + 1 top |
| upgradable to 4-side), field angles | 30° / 80° / 120° |
| Electrical Interfaces | 25 DC leads pre-routed to annular PCB around sample stage |
| RF Interfaces | 2 standard coaxial (upgradable to 4) |
| Vacuum Performance | <5.5 × 10⁻⁸ Torr |
| Cool-down Time | ~12 h to 1.7 K |
| Warm-up Time | ~2 h |
| Integrated Control | Touchscreen HMI + API-enabled software (Python, MATLAB, LabVIEW, C compatible) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VPF-100 |
| Quotation | Upon Request |
| Cooling Method | Liquid Nitrogen (LN₂) Fill |
| Temperature Range | 65 K to 500 K (VPF-100), 65 K to 800 K (VPF-100-H) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum (~10⁻⁴ Torr) |
| Sample Types | Conductive, Solid |
| Cool-down Time to 77 K | 15 min |
| LN₂ Hold Time at 77 K | 8 h (VPF-100), 5 h (VPF-100-H) |
| LN₂ Hold Time at 100 K | 4.5 h |
| LN₂ Hold Time at 200 K | 2.5 h |
| Optical Window | Standard |
| Height (approx.) | 583 mm |
| Sample Chamber Inner Diameter | 76.2 mm (VPF-100), 63.5 mm (VPF-100-H) |
| Sample Mounting Diameter | 31.75 mm |
| Net Weight (approx.) | 3.3 kg |
| Shipping Weight (approx.) | 9.1 kg |
| Shipping Dimensions (approx.) | 610 × 406 × 305 mm |
| Brand | Montana Instruments |
|---|---|
| Origin | USA |
| Model | CryoAdvance™ Series |
| Instrument Type | Vertical Cryostat |
| Temperature Stability | <10 mK (peak-to-peak) |
| Operating Temperature Range | 3.2 K – 350 K (down to <3 K under no thermal load) |
| Working Distance | Horizontal 14.5 mm, Vertical 9 mm (with optional ≤4 mm near-working-distance configuration) |
| Vibration Stability | <10 mK equivalent displacement (peak-to-peak) |
| Form Factor | Benchtop |
| Cooling Method | Closed-cycle cryorefrigeration (no liquid helium consumption) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-800 |
| Price | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <4.5 K to 300 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Exchange Gas (He) |
| Optical Window | Optional |
| Sample Loading | Top-Access |
| Sample Chamber Inner Diameter | 38 mm |
| Rotatable Sample Stage | Yes |
| Cool-Down Time | 2–2.5 h |
| Cryocooler Mounting | Bottom-Mounted |
| Vibration-Induced Linewidth Broadening | ≤0.01 mm/s (Δv/v) |
| Approximate Height | 142–168 cm |
| Weight | 27.2 kg (cryostat only) |
| Window Block Outer Diameter | 57.2 mm |
| Recommended Cryocooler Maintenance Interval | 13,000 h |
| Sample Exchange Time | ~5 min |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CCS-TRAP / CCS-TRAP-H |
| Pricing | Upon Request |
| Cooling Type | Closed-Cycle Refrigeration |
| Temperature Range | <8 K to 325 K / <9 K to 500 K |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | High Vacuum |
| Cool-down Time | 1–1.5 h |
| Cold Head Position | Bottom-Mounted |
| Approx. Height | 91.4 cm / 96.5 cm |
| Approx. Weight | 19.1 kg |
| Recommended Refrigerator Maintenance Interval | 13,000 h |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | ST-400 |
| Cooling Method | Liquid Helium (with optional RGC helium recirculator) |
| Temperature Range | 2 K to 500 K (ST-400) |
| Base Pressure | ≤1×10⁻¹¹ Torr |
| Temperature Stability | ±50 mK |
| Cool-down Time to 5 K | ≤15 min |
| Sample Environment | High-vacuum or ultra-high vacuum (UHV) chamber |
| Sample Mounting | Customizable sample holders (optical, DC, 4-probe, plug-in) |
| Optical Window Options | X-ray to THz spectral range |
| Electrical Feedthroughs | DC, BNC, SMA, triaxial |
| Initial LN₂ Consumption @ 80 K | 0.1 L/h |
| Liquid Helium Consumption @ 5 K | 0.6 L/h |
| System Mass (excl. transfer lines) | ~4.6 kg |
| Required Initial Pump-down | ~10⁻³ Torr |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | STVP-NMR |
| Pricing | Upon Request |
| Temperature Range | <2 K (1.5 K in single-point mode) to 325 K (420 K optional) |
| Typical Temperature Stability | ±50 mK |
| Sample Environment | Continuous-flow helium vapor |
| Cooling Method | Liquid Helium |
| Cool-down Time | 30 min to 5 K |
| Sample Chamber Internal Diameter | 55 mm |
| Installation Orientation | Vertical (required below 4.5 K) |
| Liquid Helium Consumption | 0.5 L (from RT to 4.2 K) |
| Approx. Weight (unit only) | 7 kg |
| Approx. Shipping Weight | 79 kg |
| Approx. Shipping Dimensions | 1905 × 990.6 × 431.8 mm |
| Compatibility | Optimized for 89 mm bore NMR magnets, customizable for other bores |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | OptiCool |
| Instrument Type | Vertical Cryostat |
| Temperature Stability | ±0.2% (T < 20 K) |
| Working Distance | 3 mm |
| Temperature Range | 1.7 K to 350 K |
| Vibration Stability | <10 nm peak-to-peak (horizontal) |
| Cooling Medium | Helium-free, dry-cycle pulse-tube refrigeration system |
| Optical Access | 7 side ports (NA > 0.11), 1 top port (NA > 0.7) |
| Magnetic Field | ±7 T |
| Sample Space | Ø89 mm × 84 mm |
| Electrical Feedthroughs | Standard 16 leads (expandable to 80) |
Show next