Raman Spectrometer
Filter
Showing 121–150 of 267 results
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Product Type | Portable / Handheld Raman Spectrometer |
| Model | i-Raman Plus |
| Spectral Range | 175–4000 cm⁻¹ |
| Spectral Resolution | 3.0 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Low-Wavenumber Cutoff | 65 cm⁻¹ |
| Spectral Reproducibility | <0.5 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | B&W Tek (distributed by Metrohm) |
| Instrument Type | Portable/HANDHELD Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | < 8.0 cm⁻¹ @ 912 nm |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 150 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Handheld Raman Spectrometer |
| Model | Mira P |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 12–14 cm⁻¹ (FWHM) |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | ≤0.15 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Handheld Raman Spectrometer |
| Model | MIRA XTR |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Laser Wavelength | 785 nm |
| Database Size | >20,000 reference spectra |
| Standoff Distance | Up to 2 m |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (software-enabled), ISO/IEC 17025-compatible workflows |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-1064 |
| Spectral Range | 176–2900 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Repeatability | ±1 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-N |
| Spectral Range | 176 – 2900 cm⁻¹ |
| Spectral Resolution | ~9 cm⁻¹ at 912 nm |
| Compliance | Designed for forensic field use in accordance with ISO/IEC 17025–aligned operational protocols |
| Software | Embedded spectral library with remote update capability |
| Detection Technology | Conventional Raman + optional SERS (via TacPac™ accessory) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReactRaman 802L |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Repeatability | ±0.2 cm⁻¹ |
| Brand | Modu-Laser |
|---|---|
| Origin | USA |
| Product Type | Gas Ion Laser |
| Model Series | TEM₀₀ Continuous-Wave Argon Ion Laser |
| Wavelengths | 488 nm, 514.5 nm (single-line or multi-line output) |
| Output Power | Up to 300 mW (TEM₀₀, 488 nm) |
| Cooling | Air-cooled or Water-cooled Options |
| Beam Quality | M² < 1.1 |
| Polarization | Linear, >100:1 |
| Lifetime | ≥5,000 hours (typical) |
| Compliance | CE, RoHS, FDA 21 CFR Part 1040.10 |
| Brand | Montana Instruments |
|---|---|
| Origin | USA |
| Model | CryoRAMAN |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 190 nm – mid-IR (down to 150 nm with custom coatings, gratings & detectors) |
| Spectral Resolution | 0.08 nm (CCD), 0.05 nm (PMT) across entire focal plane |
| Spatial Resolution | ≥15 lp/mm @ 50% modulation (center of focal plane) |
| Minimum Raman Shift | 0.8 cm⁻¹ |
| Temperature Range | 4 K – 350 K (600 K optional) |
| Sample Positional Drift | <20 µm (4.2 K–350 K, optical axis) |
| Excitation Wavelengths | 532 nm (standard), 785 nm (optional), customizable UV–NIR–MIR sources |
| Laser Spot Size | 1–3 µm |
| Field of View | >30 µm |
| Objective NA | 0.75 (Cryo-Optic®) |
| Spectrometer Options | FERGIE® (f/4, 80.08 mm FL) or IsoPlane® SCT320 (f/4.6, 320 mm FL) |
| Polarization-Resolved Capability | Yes (interchangeable polarization filtering modules) |
| Electrical Transport Integration | CryoChip16-compatible, 16-channel DC measurement platform |
| Automation | Fully automated cryostation (Cryostation® S100), touch-screen + PC control |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | NanoAppo |
|---|---|
| Origin | Tianjin, China |
| Model | EasyPeak |
| Type | SERS Enhancement Substrate |
| Substrate Composition | Colloidal Silver (Ag) and Colloidal Gold (Au) Nanoparticle Suspensions |
| Storage Condition | 4 °C |
| Shelf Life | Ag-based: 8 months |
| Au-based | 3.5 months |
| Detection Limit (Ag) | 3 × 10⁻⁶ mol/L (2-mercaptopyridine probe) |
| Detection Limit (Au) | 3 × 10⁻⁹ mol/L (Rhodamine 6G probe) |
| Enhancement Factor (Au) | >10⁹ |
| Compliance | Designed for ASTM E1840-23 and ISO/IEC 17025-compliant Raman workflows |
| Software Compatibility | Compatible with standard Raman spectrometer control software (e.g., Thermo Fisher OMNIC, Horiba LabSpec, Renishaw WiRE) |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Raman Microspectroscopy Platform with Integrated Photoconductive Mapping Capability |
| Laser Compatibility | 400–730 nm (VIS) and 780–1000 nm (NIR) |
| Spatial Resolution | 1 µm (X/Y/Z) |
| Scan Area | 200 × 200 µm |
| Objective Options | 5×, 40× Long Working Distance |
| Compatible SMUs | Keithley 2400 & 2600 Series |
| Software | NanoPhotocurrent v3.x (GLP-compliant data logging, CSV export, multi-region mapping) |
| Compliance | ASTM E2971 (Raman Microspectroscopy), ISO/IEC 17025 traceable calibration support, FDA 21 CFR Part 11 ready (audit trail & electronic signature optional) |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Type | Confocal Micro-Raman Spectrometer with Integrated Maskless Spatial Light Modulation |
| Excitation Architecture | DMD + SLM Dual-Modulated Wideband Illumination Platform |
| Optical Configuration | Upright Research-Grade Microscope Coupled to Broadband Source & Tunable Monochromatic Selection (VIS–NIR–MIR) |
| Software Integration | NanoSpectrum Suite with Keithley 2400/2600 Series SMU Compatibility |
| Compliance | GLP/GMP-ready data logging, ASTM E2587-compliant measurement traceability, ISO/IEC 17025-aligned calibration framework |
| Environmental Operation | Compatible with cryogenic stages (4 K–300 K), in-plane/out-of-plane magnetic fields (up to 9 T), and controlled-atmosphere chambers |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelengths (Standard) | 532 nm, 633 nm, 785 nm |
| Laser Linewidth | ≤1 MHz |
| SMSR | ≥30 dB |
| Wavelength Stability | ≥1 pm |
| Power Stability (8 h) | ±1% |
| Spectrometer Focal Length | 833 mm |
| Grating Options | 1800 lp/mm @ 400 nm, 1200 lp/mm @ 650 nm, 300 lp/mm @ 500 nm |
| Spectral Resolution (Reference) | 0.033 nm / 29.25 cm⁻¹ (with 1800 lp/mm grating, 25 µm pixel) |
| Minimum Detectable Raman Shift | 125 cm⁻¹ |
| Optical Filter Options | Edge filter (<100–3750 cm⁻¹), Optional ultra-low-frequency filter (<250 cm⁻¹) with bandpass + OD3 dual-stage rejection |
| Detector | Back-illuminated deep-depletion CCD, 2000 × 256 pixels, 15 µm × 15 µm pixel size |
| Scanning Method | Galvo-based laser scanning (non-contact, sample-static mapping) |
| Mapping Precision | ≤20 nm lateral positioning accuracy |
| Objective Options | 10×, 20×, 40× (default), 50×, 100×, Long WD 20×/40× |
| Software | NanoSpectrum Suite (supports .txt, .csv, .spm export), NanoControl mobile app for remote monitoring |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated TCSPC-Based TRPL/FLIM Module |
| Spectrometer | XPE200 Transmission Grating Spectrometer (f/5, 200 mm focal length) |
| Detector | Back-Illuminated CCD (2000 × 256 pixels, 15 µm × 15 µm pixel size, −50 °C thermoelectric cooling) |
| Laser Excitation Options | 405 nm, 532 nm (standard), 633 nm, 785 nm, 1064 nm (custom) |
| Raman Mapping Mechanism | Galvo-Based Laser Scanning (no sample movement, ≤20 nm positioning accuracy, up to 200 µm × 200 µm field with 40× objective) |
| TRPL Module | PicoQuant-integrated TCSPC system (405 nm ps diode laser, SPAD detector, 25 ps time resolution, dual-channel time-tagging electronics, 40 MHz max count rate) |
| Software | NanoSpectrum Suite (supports .txt/.csv spectral export, .spm/.csv mapping export, remote monitoring via NanoControl mobile app, optional Raman library identification) |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Model | PL_Mapping_System |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Photocurrent Mapping Capability |
| Spectral Range | 30–6000 cm⁻¹ |
| Spectral Resolution | < 0.02 µm (equivalent to < 0.5 cm⁻¹ at 532 nm) |
| Spatial Resolution | < 0.02 µm (diffraction-limited, dependent on objective NA and excitation wavelength) |
| Spectral Reproducibility | < 0.1 µm (wavelength stability over time and position) |
| Excitation Wavelengths | 445, 532, 635, 808, 1530 nm |
| Field of View | 200 µm × 200 µm (with 40×, NA = 0.75 objective) |
| XY Stage Travel | 150 mm × 150 mm (5 µm resolution) |
| Z-Travel | ±10 mm (1 µm resolution) |
| Probe Station | 6-inch vacuum chuck, gold/tungsten probes, PH-C15 high-precision manipulators, leakage current < 10 fA |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–5900 cm⁻¹ |
| Spectral Resolution | 2.5 cm⁻¹ |
| Spatial Resolution | < 0.02 µm |
| Minimum Wavenumber | < 250 cm⁻¹ |
| Spectral Reproducibility | < 0.1 µm |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Excitation Wavelength | 1064 nm |
| Compliance | FDA 21 CFR Part 11, USP <858>, Ph. Eur. 2.2.48, JP 2.26, ChP 2020 Raman Spectroscopy General Chapter |
| Application Focus | GMP-compliant raw material identity testing (RMIT), incoming material verification, counterfeit detection |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Models | EasyPeak™ Au Colloidal Sol, EasyPeak™ Ag Colloidal Sol |
| Price Range | USD 7,000 – 14,000 |
| Instrument Category | SERS Enhancement Reagents (Consumable/Accessory for Raman Spectrometers) |
| Spectral Range | Not Applicable (Substrate-Level Material) |
| Spectral Resolution | Not Applicable |
| Spatial Resolution | Not Applicable |
| Minimum Wavenumber | Not Applicable |
| Spectral Reproducibility | Not Applicable |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable options) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window selection) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Optical NA | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ capacitive multi-touch LCD (720p) |
| Data Interfaces | USB 2.0, Wi-Fi |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (main unit) |
| Operating Temperature | 0–45 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Numerical Aperture | 0.22 |
| Working Distance | 7.5 mm |
| Display | 4.5″ LCD, 720p capacitive multi-touch |
| Data Interfaces | USB 2.0, Wi-Fi |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (unit) |
| Operating Temperature | 0–45 °C |
| Data Formats | .pdf, .csv, .txt, .jdx, .rdb |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 170–3900 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Detector | Deep-Cooled Back-Illuminated CCD |
| Excitation Wavelength | 785 nm (standard), optional 532 nm or 1064 nm configurations |
| Laser Stability | <±0.02 nm over 8 hours |
| Spectral Reproducibility | <±0.5 cm⁻¹ (RMS, 24 h) |
| Data Interface | USB 3.0 and Wi-Fi 5 (802.11ac) |
| Operating Temperature | 10–40 °C |
| Weight | 1.4 kg (with battery) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | ACCUMAN SR-510 Pro |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3900 cm⁻¹ (configurable) |
| Spectral Resolution | 4–12 cm⁻¹ (dependent on grating and spectral window) |
| Laser Wavelength | 785 nm ± 0.5 nm, linewidth < 2 cm⁻¹, frequency stability < 0.1 cm⁻¹ |
| Laser Power | Up to 350 mW, 10-step linear adjustment |
| Detector | TE-cooled back-illuminated thin CCD array |
| Signal-to-Noise Ratio | 1000:1 |
| Integration Time | 0.1–30 s |
| Display | 4.5″ 720p capacitive multi-touch LCD |
| Data Interfaces | USB 2.0, Wi-Fi |
| Battery Life | >5 hours (rechargeable Li-ion) |
| Weight | 330 g (handheld probe), 3.8 kg (main unit) |
| Dimensions | 15.5 × 7.4 × 2.5 cm (probe), 29 × 22 × 10 cm (unit) |
| Operating Temperature | 0–45 °C |
| Software Features | Fluorescence background subtraction, spectral similarity matching, quantitative modeling, PDF/CSV/TXT/JDX/RDB export |
| Compliance | ASTM E1840, ISO 8573-1 (for optical path integrity), GLP/GMP-ready audit trail in software log |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HRS-5A |
| Type | Handheld Raman Spectrometer |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | 15 cm⁻¹ (typical) |
| Excitation Wavelength | 785 ± 0.5 nm (linewidth < 0.1 nm) |
| Laser Power | 0–500 mW (continuously adjustable) |
| Spectral Repeatability | ±0.5 nm |
| Dimensions (L×W×H) | 180 × 85 × 30 mm (excl. probe extension) |
| Weight | 550 g |
| Operating Temperature | −10 to 50 °C |
| Storage Temperature | −20 to 60 °C |
| Relative Humidity | ≤90% (non-condensing) |
| Battery Life | ≥3.5 h (standard), ≥12 h (optional extended-life battery) |
| Local Storage Capacity | >1,000,000 spectra |
| Display | 1920 × 1080 capacitive touchscreen |
| Onboard Camera | 13 MP |
| Positioning | GPS/BeiDou/GLONASS + Wi-Fi/4G triangulation |
| Connectivity | Wi-Fi, 4G (SIM-card enabled), Micro-USB |
| Operating System | Android-based embedded platform |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MicroTEQ-S1 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–1100 nm |
| Spectral Resolution | ~10 cm⁻¹ @ 5 µm slit |
| Spatial Resolution | 0.14–7.7 nm (dependent on objective magnification and laser wavelength) |
| Minimum Wavenumber Shift | 200 cm⁻¹ |
| Spectral Reproducibility | Not specified |
| Brand | Ocean Optics |
|---|---|
| Model | MicroTEQ-S1 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–1100 nm |
| Spectral Resolution | ~10 cm⁻¹ @ 5 µm slit |
| Spatial Resolution | 0.14–7.7 nm (dependent on objective magnification and laser wavelength) |
| Minimum Wavenumber Shift | 200 cm⁻¹ |
| Detector | Back-Illuminated, Deep-Depletion CCD |
| A/D Resolution | 18-bit |
| Dynamic Range | 85,000:1 |
| SNR | 1000:1 |
| Integration Time | 8 ms – 60 min |
| Laser Options | 405 nm, 450 nm, 532 nm, 633 nm, 785 nm (power-adjustable, up to 500 mW) |
| Microscope Objectives | 5×, 10×, 20×, 50×, optional 100× (NA 0.15–0.8) |
| Imaging Sensor | 1/2″ CMOS, 2048 × 1536 pixels |
| Motorized XY Stage (optional) | 50 mm × 50 mm travel, 1 µm resolution, 2 µm repeatability |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible workflow support |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | QE Pro Raman+ |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 150 cm⁻¹ – 4000 cm⁻¹ |
| Spectral Resolution | 0.42 nm (FWHM, typical) |
| Detector | TE-cooled 1044 × 64-pixel back-thinned FFT-CCD |
| Quantum Efficiency | 90% (peak) |
| Signal-to-Noise Ratio | 1000:1 (single acquisition) |
| Integration Time | 8 ms – 3600 s |
| Dynamic Range | ~85,000:1 |
| Optical Interface | SMA 905 |
| Onboard Memory | 15,000 spectra |
| Dimensions | 182 mm × 110 mm × 47 mm |
| Weight | 1.15 kg (instrument only) |
| Power Supply | 0.45 kg |
| Operating Temperature | 0 °C – 50 °C |
| Humidity | ≤90% RH (non-condensing) |
| Communication | USB 2.0 (480 Mbps, USB 1.1 compatible), RS-232 |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | QE Pro Raman+ |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 150 cm⁻¹ – 4000 cm⁻¹ |
| Spectral Resolution | 0.42 nm (FWHM, typical) |
| Detector | TE-cooled 1044 × 64-pixel back-thinned FFT-CCD |
| Quantum Efficiency | 90% (peak) |
| Signal-to-Noise Ratio | 1000:1 (single acquisition) |
| Integration Time | 8 ms – 3600 s |
| Dynamic Range | ~85,000:1 |
| Optical Interface | SMA 905 |
| Onboard Memory | 15,000 spectra |
| Communication | USB 2.0 (480 Mbps), RS-232 |
| Dimensions | 182 mm × 110 mm × 47 mm |
| Weight | 1.15 kg (instrument only) |
| Power Supply | 0.45 kg |
| Operating Temperature | 0 °C – 50 °C |
| Humidity | ≤90% RH (non-condensing) |
| Slit Options | 25 µm, 50 µm |
| Grating | Custom holographic grating (e.g., GRATING_#H6) |
| Excitation Wavelengths | 532 nm, 638 nm, or 785 nm (preconfigured) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Type | Grating-Based Raman Spectrometer |
| Spectral Range | 200–4500 cm⁻¹ |
| Spectral Resolution | 13 cm⁻¹ (FWHM @ 1000 cm⁻¹) |
| Spatial Resolution | 13 cm⁻¹ (calibrated at 1000 cm⁻¹) |
| Minimum Wavenumber Shift | 0.2 nm (laser-dependent) |
| Spectral Repeatability | ±1 nm (at 532 nm excitation) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Custom 2 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Custom 9 |
| Pricing | Upon Request |
| Detection Principle | Laser Raman Spectroscopy |
| Target Analytes | Monoethanolamine (MEA), Diethanolamine (DEA) |
| Concentration Range | 0–55% (w/w) |
| Accuracy | ≤ ±1% FS |
| Response Time | ≤ 30 s |
| Operating Temperature | −10 to 50 °C |
| Operating Humidity | 15–85% RH |
| Probe Configuration | In-situ or Extractive |
| System Architecture | Modular (Separated Spectrometer Unit & Immersion Probe) |