Raman Spectrometer
Filter
Showing 91–120 of 273 results
| Brand | Chemlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GenesisRaman |
| Price Range | USD 630,000 – 775,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution | ≤2 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤±0.2 cm⁻¹ |
| Brand | Gentec-EO |
|---|---|
| Origin | Canada |
| Product Type | Laser Beam Diagnostic System |
| Model | BeamWatch Active |
| Wavelength Range | 190 nm – 11 µm |
| Measurement Principle | Non-contact, real-time camera-based beam profiling with ISO 11146-compliant M² calculation |
| Compliance | ISO 11146-1:2005, ISO 11146-2:2005, ANSI Z136.1 |
| Software | BeamWatch Studio v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready export) |
| Detector Type | High-dynamic-range CMOS sensor array with motorized neutral density filter wheel |
| Spatial Resolution | ≤ 5 µm (system-limited) |
| Frame Rate | Up to 60 Hz at full resolution |
| Data Output | ASCII, CSV, HDF5, TIFF, PNG |
| Interface | GigE Vision, USB 3.2 Gen 1 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HE |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength Options | 532 nm / 633 nm / 785 nm |
| Spectral Range | 200–3200 cm⁻¹ |
| Detector | 1024 × 256 CCD array, MPP mode |
| Cooling | Peltier-cooled to −70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Power Range | 80–300+ mW |
| Power Supply | 220 V, 15 A |
| Software | LabSpec 6 (Windows-compatible) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | HE |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3200 cm⁻¹ |
| Spectral Resolution | 3 cm⁻¹ |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.25 cm⁻¹ |
| Detector | 1024 × 256-pixel CCD (MPP mode) |
| Cooling | Peltier-cooled to –70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Options | 532 nm, 633 nm, or 785 nm (output power 80–300+ mW) |
| Fiber Probe Support | Up to 4 simultaneous SuperHead™ probes |
| Optical Configurations | Standard, confocal, immersion, or microscope-coupled via 40 mm, 10×, or 50× long-working-distance objectives |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | T64000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | UV–VIS–NIR (excitation-dependent) |
| Spectral Resolution | ≤ 0.15 cm⁻¹ (triple-add mode) |
| Low-Wavenumber Limit | ≥ 5 cm⁻¹ (triple-subtract mode) |
| Spatial Resolution | Sub-micron (confocal, diffraction-limited) |
| Focal Length | 640 mm (single stage), 3 × 640 mm (triple stage) |
| Detector | Research-grade air-cooled large-format CCD |
| Laser Power Control | Multi-step neutral density attenuation |
| Optical Output | Flat-field dispersive output compatible with large-area detectors |
| Polarization Options | Full-suite polarization accessories (excitation, Raman, white-light) |
| Sample Handling | Integrated research microscope + large sample chamber |
| Optional Accessories | XYZ high-precision motorized stage, cryo/heat stages, fiber-optic probes, fast mapping module, simultaneous Stokes/anti-Stokes detection port, secondary detector outlet for PL/NIR-Raman |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HE |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | < 5 cm⁻¹ (typical, dependent on grating and slit configuration) |
| Spatial Resolution | Diffraction-limited, down to ~1 µm (with 50× long-working-distance objective and confocal option) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | < ±0.2 cm⁻¹ (over 8-hour operation, temperature-stabilized optics) |
| Detector | 1024 × 256 pixel CCD, MPP mode |
| Cooling | Peltier-cooled to −70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Wavelength Options | 532 nm, 633 nm, 785 nm |
| Laser Power Range | 80–300+ mW (adjustable per application) |
| Fiber Probe Support | Up to 4 simultaneous SuperHead™ probes |
| Software | LabSpec 6 (Windows-compatible, FDA 21 CFR Part 11–ready audit trail & user access control) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM HR Evolution |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2100 nm |
| Focal Length | 800 mm |
| Spectral Dispersion | Flat-field output optimized for large-format CCD detectors |
| Laser Power Control | Multi-step motorized neutral density filters |
| Detector | Research-grade air-cooled large-chip CCD |
| Low-Wavenumber Capability | Down to 10 cm⁻¹ |
| Spatial Resolution | Sub-micron (diffraction-limited, wavelength- and objective-dependent) |
| Automation | Fully motorized optical path, filter wheels, grating turrets, and XYZ stage |
| Software Platform | LabSpec 6 with embedded chemometrics, fluorescence subtraction, particle search, and audit-trail-ready data handling |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM HR Evolution |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | 0.6 cm⁻¹ |
| Spatial Resolution | 400 nm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Focal Length | 800 mm |
| Excitation Wavelength Range | 200–2100 nm |
| Detector | Research-Grade Air-Cooled Large-Format CCD |
| Optical Design | Achromatic Flat-Field Spectrograph |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | LabRAM Odyssey |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.35–0.65 cm⁻¹ |
| Spatial Resolution | down to 250 nm |
| Minimum Wavenumber | as low as 3.5 cm⁻¹ |
| Spectral Reproducibility | ±0.02 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LabRAM Soleil™ |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.5 cm⁻¹ |
| Spatial Resolution | <250 nm |
| Minimum Wavenumber | <5 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.01 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA |
| Instrument Type | Confocal Raman Microspectrometer |
| Laser Options | 532 nm, 638 nm, 785 nm (multi-laser integrated) |
| Grating Configuration | 4-position automated grating turret |
| Spectral Range | 100–4000 cm⁻¹ (dependent on laser/grating selection) |
| Optical Design | Flat-field spectrograph with large-format CCD detector |
| Laser Power Control | Multi-step neutral density attenuation |
| Microscope | Research-grade upright confocal microscope |
| Automation Level | Fully motorized stage, autofocus, auto-alignment, auto-calibration, auto-exposure |
| Imaging Modes | Raman mapping, fluorescence imaging, photoluminescence (PL) imaging |
| Optional Integrations | AFM coupling, polarization accessories, cryo/heat stages, liquid cells, macro sampling modules |
| Software | HORIBA LabSpec 6 with GO!™ guided workflow engine |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA INV |
| Instrument Type | Inverted Confocal Raman Microscope |
| Laser Options | 532 nm, 638 nm, 785 nm (3 internal lasers) |
| Grating Options | 600, 1200, 1800, 2400 gr/mm (motorized auto-switching) |
| Spectral Range | 250–10,000 cm⁻¹ (configurable per laser/grating combination) |
| Laser Power Control | Multi-step neutral density attenuation |
| Automation | Auto-focus, auto-exposure, auto-calibration, self-diagnostic routine |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Optional Modules | DuoScan™ high-speed Raman imaging, SWIFT™ fast spectral acquisition, epifluorescence integration, polarization optics, precision XYZ stage, environmental stages (cryo/heated/biological incubation), AFM/Raman coupling interface, fiber-optic probe compatibility |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA INV |
| Instrument Type | Inverted Confocal Raman Microscope |
| Laser Options | 532 nm, 638 nm, 785 nm (multi-laser auto-switching) |
| Grating Options | 4 gratings auto-switched (600, 1200, 1800, 2400 gr/mm) |
| Spectral Range | 250–10,000 cm⁻¹ (configurable per laser/grating combination) |
| Spatial Resolution | Sub-micron (diffraction-limited, dependent on objective and wavelength) |
| Automation | Auto-focus, auto-exposure, auto-calibration, self-diagnostic |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-supportive workflow logging |
| Optional Modules | DuoScan™ high-speed Raman imaging, SWIFT™ fast spectral acquisition, epifluorescence integration, polarization control, precision XYZ stage, environmental stages (cryo/heated/biological incubation), AFM-Raman coupling interface |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA PLUS XS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral 0.4 µm, Axial 1.5 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.03 cm⁻¹ |
| Maximum Acquisition Speed | 1600 spectra/s |
| Pixel Dwell Time | <1 ms/pixel |
| Automated Laser Selection | Up to 3 Integrated Lasers (532 nm, 638 nm, 785 nm) |
| Grating Options | 4 Motorized Gratings |
| Detection | EMCCD and XS Fast-Imaging Detector |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MacroRAM |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 100–3400 cm⁻¹ |
| Spectral Resolution | 8 cm⁻¹ at 914.9 nm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.03 cm⁻¹ |
| Excitation Wavelength | 785 nm |
| Max Laser Power | 450 mW (software-controllable, continuous variable) |
| Detector | Back-Thinned CCD, cooled to –50 °C, 80% QE at 800 nm |
| Dark Current | 0.05 e⁻/pixel/sec at –50 °C |
| Dynamic Range | 42,550:1 |
| Fiber Input | 100 µm core diameter, female FC/PC connector, NA = 0.15 |
| Dimensions (W × D × H) | 432 × 432 × 381 mm (17 × 17 × 15 in) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Nano XploRA |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy (AFM) |
| Optical Coupling Options | Top, Side, and Bottom Illumination Paths |
| Objective Compatibility | Supports High-NA ×100 Objectives for All Coupling Modes |
| TERS-Ready Architecture | Fully Optimized for Tip-Enhanced Raman Scattering |
| AFM Feedback | Automatic Laser Alignment via Photodiode-Based Optical Lever System |
| Scan Head | High-Frequency, Low-Noise Piezoelectric Scanner |
| Software Integration | Unified Control Suite for Synchronized AFM Topography, Mechanical Mapping, and Point/Line/Area Raman Spectroscopy |
| Compliance Framework | Designed to Support GLP/GMP workflows with audit-trail-capable data logging (21 CFR Part 11-ready configuration available) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | RZ-660 |
| Price | Upon Request |
| Spectral Range | 680 – 3,800 cm⁻¹ |
| Spatial Resolution | < 5 µm |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | T64000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution (Additive Mode) | 0.15 cm⁻¹ |
| Low-Wavenumber Limit (Subtractive Mode) | 5 cm⁻¹ |
| Focal Length (Single Stage) | 640 mm |
| Total Focal Length (Triple Additive) | 3 × 640 mm |
| Excitation Range | UV–VIS–NIR |
| Detector | Research-Grade Air-Cooled Large-Format CCD |
| Optical Output | Flat-Field Spectral Dispersion |
| Laser Power Control | Multi-Step Attenuation Wheel |
| Configuration Options | Confocal Microscopy & Macro Sample Chamber |
| Polarization Compatibility | Full-Line (Excitation, Raman, White Light) |
| Optional Detectors | Secondary Output Port for PL or NIR Raman |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA Nano |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution (TERS mode) | <10 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <0.1 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | XploRA Nano |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution (TERS) | <10 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | <0.1 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XploRA PLUS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 0.4 µm, Axial 1.5 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.03 cm⁻¹ |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | HyperFlux™ PRO Plus (HFPP) |
| Laser Wavelength | 785 nm |
| Safety | Integrated laser interlocks |
| Optical Architecture | HTVS™ (High-Throughput Virtual Slit) Technology |
| Spectral Resolution | High (maintained under high-throughput conditions) |
| Deployment | Benchtop & In-line Process Monitoring |
| Compliance | FDA 21 CFR Part 11, ATEX/IECEx for hazardous areas |
| Software | SpectralSoft™ v5.x |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | gora |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelengths | 532 nm, 633 nm, 785 nm |
| Spectral Resolution | 1.08 cm⁻¹ @ 585 nm (1800 grooves/mm grating, 500 mm focal length) |
| Spatial Resolution | <0.9 µm (XY) |
| Minimum Detectable Raman Shift | 10 cm⁻¹ (customizable to <10 cm⁻¹ with low-wavenumber notch filter) |
| Spectral Reproducibility | <0.9 µm (XY) |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | K-Sens |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 150–4000 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Spatial Resolution | 0.1 mm (lateral), 0.1 mm (axial) |
| Minimum Wavenumber | 150 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.1 cm⁻¹ |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | Kun |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Laser Options | 532 nm & 785 nm fiber-coupled lasers |
| Spectral Range | 175–4000 cm⁻¹ (configurable) |
| Spectral Resolution | up to 2.5 cm⁻¹ |
| Detector | 2048-pixel back-thinned CCD |
| Peak Quantum Efficiency | 75% |
| Cooling | Uncooled architecture |
| Power Consumption | Low-power design |
| Modularity | Independent laser, probe, and spectrometer modules |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-1w |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 3000–200 cm⁻¹ |
| Spectral Resolution | 3 cm⁻¹ per pixel |
| Laser Excitation Wavelength | 785 nm |
| Detector | Uncooled CMOS |
| Interface | USB 2.0 for PC connectivity |
| Measurement Time | ~2–3 minutes per sample |
| Sample Compatibility | Solids, powders, liquids (including through transparent packaging) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SSR-3000 |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 180–3300 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Signal-to-Noise Ratio | 400:1 @ 100 ms integration time |
| Excitation Wavelength | 785 ± 0.5 nm |
| Laser Linewidth | < 0.06 nm |
| Output Power | 0–500 mW (digitally adjustable) |
| Integration Time | 10 ms – 20 min |
| Weight | < 4 kg |
| Dimensions | 370 × 270 × 120 mm |
| Power Supply | External AC 100–240 V, 50/60 Hz |
| Internal Battery | 12 V, 8000 mAh Li-ion (laptop-grade) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RA 200 |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3000 cm⁻¹ |
| Spectral Resolution | <6 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Minimum Wavenumber | 150 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlameMaster Raman |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 300–800 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 1 mm |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.15 cm⁻¹ |
| Brand | Lightnovo |
|---|---|
| Origin | Denmark |
| Type | Confocal Micro-Raman Spectrometer |
| Model | Micro-Raman Microscope |
| Spectral Range | 786 cm⁻¹ (excitation wavelength, typically 785 nm laser) |
| Spectral Resolution | 2.5–3 cm⁻¹ |
| Lateral Spatial Resolution | 800–900 nm |
| Axial (Z) Resolution | 2.5–3 µm |
| Dimensions | 175 × 180 × 410 mm |
| Weight | 9.5–11.5 kg |
| Microscope Configuration | Upright & Inverted |
| XYZ Travel Range (Motorized) | 30 × 30 × 30 mm |
| XYZ Travel Range (Manual) | 10 × 10 × 13 mm |
| Minimum Step Size | 500 nm (XY), 500 nm (Z) |
| White-Light Reflectance Imaging | Integrated real-time camera with simultaneous laser spot visualization and Raman acquisition |