- All
- Favorite
- Popular
- Most rated
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000D |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 50–1000 W (continuously adjustable) |
| Operating Frequency | 20–30 kHz (auto-tuned, LCD-displayed) |
| Temperature Control Range | −5 to 100 °C (optional −120 to 300 °C) |
| Sample Volume Capacity | 50–600 mL (glass double-jacketed reactors: 50 / 100 / 250 / 500 mL) |
| Stirring Speed | 0–2400 rpm (magnetic, continuously adjustable) |
| Horn Diameter | Φ10 mm or Φ12 mm (titanium alloy, immersion-type) |
| Pulse Mode | Independent on/off control, adjustable pulse duration and automatic pulse counting |
| Sealing Interface | Standard ground-glass joints (e.g., 24/24, 50/50), custom configurations available |
| Cooling/Heating Medium | Circulating water or thermal oil via jacket |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000 |
| Ultrasonic Output Power | 1000 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | –5 °C to 100 °C (with optional chiller) |
| Maximum Sample Volume | 1000 mL |
| Pulse Mode Interval | 0.1–99.9 s adjustable |
| Total Processing Time | 0–99 h 59 min 59 s |
| Programmable Memory | 20 user-defined protocols |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Touchscreen Interface | 4.3″ TFT LCD |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | Daxluot |
|---|---|
| Model | Dxluot-4SKI |
| Origin | Shanghai, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 12–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume per Channel | 1–10 mL |
| Number of Simultaneous Samples | 4 |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated |
| Programmable Parameters | 20 user-defined protocols |
| Ultrasound On/Off Time | 0.1–99.9 s (adjustable) |
| Total Cycle Duration | 0.1 s – 99 h 59 min 59 s |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Data Logging | Timestamped protocol execution history |
| Cooling Integration | Integrated Peltier-assisted cold block with recirculating thermal management |
| Brand | Hanuo |
|---|---|
| Model | TYZD-I |
| Type | Microplate Vibrator (Non-temperature-controlled, Orbital Shaking) |
| Operating Frequency | 1500 rpm |
| Amplitude | 6 mm |
| Timer Range | 0–120 min or Continuous Mode |
| Input Voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 220 × 180 × 130 mm |
| Tray Material | Medical-grade Silicone Mat |
| Plate Capacity | Up to 4 standard microplates (stacked) |
| Compliance | CE-marked for laboratory use (IEC 61010-1), RoHS-compliant |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | Hannuo-950EW |
| Ultrasonic Power | 950 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–700 mL (with interchangeable probes) |
| Probe Diameter (Standard) | Φ6 mm |
| Pulse Mode | 0.1–99.9 s ON/OFF adjustable |
| Duty Cycle | 0.1–99.9% |
| Power Adjustment Range | 1–99% (10–950 W) |
| Display | 7-inch TFT touch screen |
| Data Storage | 20 user protocols |
| Communication Interface | RS-232/USB for PC connectivity |
| Safety Features | Overtemperature, overload, no-load, and self-diagnostic alarms |
| Optional Accessories | Cryogenic cooling module, motorized probe lift, acoustic isolation chamber |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-8S |
| Ultrasonic Power | 20–2000 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 8 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic Load-Compensated |
| Data Storage | 20 Preset Protocols |
| Display | 7-inch TFT Touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | KR-B |
| Instrument Type | Other Oscillators / Shakers |
| Timing Range | Not Available |
| Oscillation Frequency | 1200 cycles/min |
| Oscillation Amplitude | 8 mm |
| Temperature Control | Not Available |
| Number of Shaking Plates | 1 |
| Power Consumption | 40 VA |
| Input Voltage/Frequency | AC 220 V, 50 Hz |
| Capacity | Up to 20 sample vials/bottles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HY-6 |
| Instrument Type | Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 0–220 rpm |
| Orbit Diameter | 20 mm |
| Platform Quantity | 1 |
| Motor Power | 100 W |
| Tray Dimensions | 60 × 50 × 2 cm |
| Warranty | 1 year standard, lifetime technical support |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RH-100 |
| Quotation | USD 650 (FOB Shanghai) |
| Instrument Type | Flip-Over Shaker |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 10–100 rpm |
| Motion Profile | 3D Tumble Rotation (Flip + Roll + Pitch) |
| Temperature Control | None |
| Platform Quantity | 1 |
| Load Capacity | 6 kg |
| Input Power | 25 W |
| Voltage/Frequency | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 485 × 200 × 226 mm |
| Net Weight | 5.90 kg |
| Programmable Modes | Independent or combinable execution of rotation, flip-over, and pause sequences |
| Pause Duration Setting | 1–5 s per cycle |
| Flip/Rotate Timing | 1–250 s per phase |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-4SKII |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 18–1800 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 4 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Safety Protections | Overtemperature, over-power, and overtime cutoffs |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Cryogenic Compatibility | Integrated Peltier-cooled sample rack with external chiller port |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Frequency | 20 kHz |
| Maximum Ultrasonic Power | 1200 W |
| Temperature Range | 0–99 °C |
| Sample Volume per Tube | 0.1–2 mL |
| Number of Simultaneous Samples | 4 or 6 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Cooling Interface | Yes (for external chiller connection) |
| Display | Large LCD |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-1500 |
| Type | Orbital Microplate Shaker |
| Timing Range | 0–99 h 59 min or Continuous Mode |
| Speed Range | 300–1500 rpm (300–1000 rpm under full load) |
| Orbit Diameter | 3 mm |
| Platform Capacity | 4 standard microplates (96-well format) |
| Dimensions (W×D×H) | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Drive System | Brushless DC Motor |
| Display | LED Digital Display |
| Alarm | Audible End-of-Timer Alert |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTC-100 |
| Oscillation Frequency | 300–1800 rpm |
| Oscillation Amplitude | 3 mm (horizontal rotation) |
| Temperature Range | −5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Cooling Rate | ≥7°C/min (100°C → 20°C), ≥1.2°C/min (ambient → ambient −20°C at 30°C ambient) |
| Timer Range | 0–99 h 59 min, multi-step programming |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 8.3 kg |
| Standard Plate | 1 interchangeable module included |
| Optional Modules | A–N series (including 96-well PCR plates, 0.2–50 mL tube formats, deep-well plates, and custom cavities) |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-24S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 25–2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Channel | 0.1–5 mL |
| Number of Simultaneous Samples | 24 |
| Display | 7-inch TFT Touchscreen |
| Data Storage | 20 Preset Protocols |
| Amplitude Control | Auto-compensated |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature, Overpower, and Overtime Protection |
| Cooling Interface | Integrated Low-Temperature Circulating Rack (−5 to 100 °C) |
| Communication Option | RS-232/USB (optional) |
| Footswitch Support | Optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTH-100 |
| Instrument Type | Heated Orbital Shaker / Incubating Mixer |
| Timer Range | 0–99 h 59 min, multi-segment programming |
| Oscillation Speed | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (horizontal orbital) |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Temperature Stability | ±0.3 °C |
| Temperature Display Resolution | 0.1 °C |
| Heating Rate | <15 min (20 °C → 100 °C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 6.8 kg |
| Platform | Single interchangeable plate (multiple well-format compatible) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | SHZ-82 |
| Instrument Type | Air-bath constant-temperature orbital shaker |
| Temperature Range | Ambient to 50 °C |
| Temperature Uniformity | ±0.5 °C |
| Oscillation Mode | Orbital |
| Oscillation Frequency | 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Timer Range | 0–120 min |
| Heating Power | 500 W |
| Number of Platforms | 1 |
| Construction | Stainless steel chamber interior |
| Drive System | Mechanical speed control with smooth, low-vibration transmission |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IIIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 3500 W |
| Operating Frequency | 19–30 kHz |
| Temperature Range | −5 °C to 100 °C (expandable with external chiller) |
| Sample Volume per Tube | 0.1–2 mL |
| Parallel Sample Capacity | 4–32 tubes |
| Display & Control | Touchscreen Interface |
| Communication Options | RS232/RS485 port (optional) |
| Cooling Interface | Integrated water-circulation coupling port (chiller compatible) |
| Duty Cycle | 1–99.9% adjustable |
| Power Supply | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN-1000Y |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1000 W |
| Operating Frequency | 22 kHz |
| Temperature Range | 0–99 °C |
| Sample Volume Capacity | 1000 mL |
| Sample Throughput | Single-sample operation |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Dalxuot-300M |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 28–30 kHz |
| Ultrasonic Power Output | 30–300 W (adjustable) |
| Sample Volume Capacity | 0.1–300 mL |
| Sample Throughput | Single-sample processing |
| Input Power | 100–230 V AC, 50–60 Hz or 12–24 V DC |
| Weight | 0.5 kg |
| Dimensions (L×W) | 300 × 43 mm |
| Transducer Material | 7075 Aluminum Alloy |
| Horn Material | TC4 Titanium Alloy |
| Housing Material | ABS + Flame-Retardant Additive |
| Operating Temperature | 5–30 °C |
| Relative Humidity | ≤70% RH |
| Standard Probe Diameter | Ø6 mm |
| Optional Probes | Ø2 mm (0.1–5 mL), Ø6 mm (5–100 mL), Ø8 mm (50–300 mL) |
| Continuous Sonication Duration | <40 min |
| Control Mode | Manual push-button activation (momentary contact) |
| Display | DC input voltage only |
| Optional Accessory | Adjustable transducer support stand (300 × 225 × 320 mm) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | SHA-CA |
| Instrument Type | Water Bath Constant-Temperature Shaker / Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient to 100 °C |
| Number of Shaking Platforms | 1 |
| Temperature Uniformity | ±0.5 °C |
| Display | Digital LED (Temperature & Speed) |
| Oscillation Mode | Reciprocating |
| Chamber Material | Stainless Steel (304) |
| Platform Dimensions | 39 × 29 cm |
| External Dimensions | 71 × 55 × 49 cm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HND-2000 |
| Instrument Type | Vortex Mixer |
| Timing Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 500–2500 rpm |
| Oscillation Amplitude | 4 mm (orbital diameter) |
| Speed Accuracy | ±10 rpm (at 2500 rpm) |
| Capacity | 15 × 50 mL tubes |
| Max Load | 5 kg |
| Top Plate Dimensions | 311 × 184 mm |
| Overall Dimensions | 426 × 250 × 432 mm |
| Net Weight | 21.5 kg |
| Power Supply | 100–230 V, 50/60 Hz |
| Power Consumption | 70 W |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HY-6A |
| Instrument Type | Orbital Shaker |
| Timing Range | 0–120 min |
| Oscillation Speed | 0–220 rpm |
| Orbit Diameter | 20 mm |
| Temperature Control | None |
| Shelf Quantity | 2 |
| Motor Power | 100 W |
| Tray Dimensions | 60 × 50 × 2 cm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNGS-30 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 30 mm |
| Load Capacity | 2 kg |
| Operating Temperature | 4–45 °C |
| Dimensions (W×D×H) | 284 × 264 × 90 mm |
| Input Voltage | AC 100–230 V |
| Power Supply Type | Universal voltage compatible |
| Motor Type | Brushless DC motor |
| Display | LED digital display for speed and timer |
| Platform Options | Interchangeable platforms (conical flask holder, adjustable flask rack, universal tray) |
| Platform Quantity | Up to 4 platforms (optional) |
Show next