- All
- Favorite
- Popular
- Most rated
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000D |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 50–1000 W (continuously adjustable) |
| Operating Frequency | 20–30 kHz (auto-tuned, LCD-displayed) |
| Temperature Control Range | −5 to 100 °C (optional −120 to 300 °C) |
| Sample Volume Capacity | 50–600 mL (glass double-jacketed reactors: 50 / 100 / 250 / 500 mL) |
| Stirring Speed | 0–2400 rpm (magnetic, continuously adjustable) |
| Horn Diameter | Φ10 mm or Φ12 mm (titanium alloy, immersion-type) |
| Pulse Mode | Independent on/off control, adjustable pulse duration and automatic pulse counting |
| Sealing Interface | Standard ground-glass joints (e.g., 24/24, 50/50), custom configurations available |
| Cooling/Heating Medium | Circulating water or thermal oil via jacket |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2000 |
| Instrument Type | Darkroom-style transilluminator |
| Wavelength | 302 nm (single-band) |
| Transmission UV Filter Size | 200 × 150 mm |
| Reflective UV Filter Size | 200 × 80 mm |
| UV Lamp Power (Transmissive) | 64 W |
| UV Lamp Power (Reflective) | 24 W |
| White Light Illumination Power | 40 W |
| Input Voltage | 220 V AC |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000 |
| Ultrasonic Output Power | 1000 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | –5 °C to 100 °C (with optional chiller) |
| Maximum Sample Volume | 1000 mL |
| Pulse Mode Interval | 0.1–99.9 s adjustable |
| Total Processing Time | 0–99 h 59 min 59 s |
| Programmable Memory | 20 user-defined protocols |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Touchscreen Interface | 4.3″ TFT LCD |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | Daxluot |
|---|---|
| Model | Dxluot-4SKI |
| Origin | Shanghai, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 12–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume per Channel | 1–10 mL |
| Number of Simultaneous Samples | 4 |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated |
| Programmable Parameters | 20 user-defined protocols |
| Ultrasound On/Off Time | 0.1–99.9 s (adjustable) |
| Total Cycle Duration | 0.1 s – 99 h 59 min 59 s |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Data Logging | Timestamped protocol execution history |
| Cooling Integration | Integrated Peltier-assisted cold block with recirculating thermal management |
| Brand | Hanuo |
|---|---|
| Model | TYZD-I |
| Type | Microplate Vibrator (Non-temperature-controlled, Orbital Shaking) |
| Operating Frequency | 1500 rpm |
| Amplitude | 6 mm |
| Timer Range | 0–120 min or Continuous Mode |
| Input Voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 220 × 180 × 130 mm |
| Tray Material | Medical-grade Silicone Mat |
| Plate Capacity | Up to 4 standard microplates (stacked) |
| Compliance | CE-marked for laboratory use (IEC 61010-1), RoHS-compliant |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-SP96G |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL tubes and 8-tube strips) |
| Heating Rate | 5 °C/s |
| Cooling Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C |
| Temperature Uniformity (Well-to-Well) | ≤±0.2 °C |
| Gradient Range | 30–105 °C |
| Gradient Span | 0.1–30 °C |
| Block Material | Anodized Aluminum |
| Heat Lid Temperature Range | 30–115 °C |
| Heat Lid Pressure | Auto-adjusting spring-loaded mechanism |
| Display | 7-inch resistive touchscreen (800 × 480 resolution) |
| Onboard Storage | >10,000 protocols |
| Data Interface | Dual USB 2.0 ports |
| Power Input | AC 100–240 V, 50–60 Hz |
| Max Power Consumption | 800 W |
| Dimensions (W×D×H) | 420 × 260 × 245 mm |
| Weight | 11 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNUV-II |
| Instrument Type | Darkroom-style UV Crosslinker |
| UV Wavelength | 254 nm |
| UV Lamp Configuration | Five 10 W low-pressure mercury lamps (total nominal output 50 W) |
| Exposure Time Range | 0.1–999.9 min (0.1 min resolution) |
| Exposure Energy Settings | 9 programmable and persistent energy presets |
| Exposure Time Settings | 9 programmable and persistent time presets |
| Display | Monochrome LCD with Chinese interface |
| Control Interface | Touch-sensitive keypad |
| UV Shielding View Window | Yes |
| Chamber Material | Stainless steel interior |
| Chamber Dimensions (L×W×H) | 340 × 260 × 150 mm |
| External Dimensions (L×W×H) | 360 × 340 × 310 mm |
| Power Supply | 220 V AC, 50 Hz |
| Compliance | Designed for laboratory use in nucleic acid immobilization, UV sterilization, and photochemical crosslinking applications per standard molecular biology workflows |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | Hannuo-950EW |
| Ultrasonic Power | 950 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–700 mL (with interchangeable probes) |
| Probe Diameter (Standard) | Φ6 mm |
| Pulse Mode | 0.1–99.9 s ON/OFF adjustable |
| Duty Cycle | 0.1–99.9% |
| Power Adjustment Range | 1–99% (10–950 W) |
| Display | 7-inch TFT touch screen |
| Data Storage | 20 user protocols |
| Communication Interface | RS-232/USB for PC connectivity |
| Safety Features | Overtemperature, overload, no-load, and self-diagnostic alarms |
| Optional Accessories | Cryogenic cooling module, motorized probe lift, acoustic isolation chamber |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-8S |
| Ultrasonic Power | 20–2000 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 8 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic Load-Compensated |
| Data Storage | 20 Preset Protocols |
| Display | 7-inch TFT Touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | KR-B |
| Instrument Type | Other Oscillators / Shakers |
| Timing Range | Not Available |
| Oscillation Frequency | 1200 cycles/min |
| Oscillation Amplitude | 8 mm |
| Temperature Control | Not Available |
| Number of Shaking Plates | 1 |
| Power Consumption | 40 VA |
| Input Voltage/Frequency | AC 220 V, 50 Hz |
| Capacity | Up to 20 sample vials/bottles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HY-6 |
| Instrument Type | Orbital Shaker |
| Timer Range | 0–120 min |
| Oscillation Frequency | 0–220 rpm |
| Orbit Diameter | 20 mm |
| Platform Quantity | 1 |
| Motor Power | 100 W |
| Tray Dimensions | 60 × 50 × 2 cm |
| Warranty | 1 year standard, lifetime technical support |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RH-100 |
| Quotation | USD 650 (FOB Shanghai) |
| Instrument Type | Flip-Over Shaker |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 10–100 rpm |
| Motion Profile | 3D Tumble Rotation (Flip + Roll + Pitch) |
| Temperature Control | None |
| Platform Quantity | 1 |
| Load Capacity | 6 kg |
| Input Power | 25 W |
| Voltage/Frequency | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 485 × 200 × 226 mm |
| Net Weight | 5.90 kg |
| Programmable Modes | Independent or combinable execution of rotation, flip-over, and pause sequences |
| Pause Duration Setting | 1–5 s per cycle |
| Flip/Rotate Timing | 1–250 s per phase |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-4SKII |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 18–1800 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 4 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Safety Protections | Overtemperature, over-power, and overtime cutoffs |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Cryogenic Compatibility | Integrated Peltier-cooled sample rack with external chiller port |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Frequency | 20 kHz |
| Maximum Ultrasonic Power | 1200 W |
| Temperature Range | 0–99 °C |
| Sample Volume per Tube | 0.1–2 mL |
| Number of Simultaneous Samples | 4 or 6 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Cooling Interface | Yes (for external chiller connection) |
| Display | Large LCD |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | PGX-150A |
| Capacity | 150 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Illumination Range | 0–3000 lx (5-level adjustable, up to 12,000 lx optional) |
| Construction | Stainless steel interior, triple-layer vacuum-insulated tempered glass door |
| Control System | Microprocessor-based programmable controller with 30-segment time/temperature/light scheduling |
| Safety Features | Over-temperature protection, sensor fault detection, power-loss memory and auto-compensation |
| Optional Accessories | Full-spectrum plant growth lamps, light-tight lamp hoods, internal power outlets, UV sterilization module |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HX-0508 |
| Temperature Range | -5 °C to 105 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.01 °C |
| Bath Volume | 8 L |
| External Circulation Flow Rate | 16–18 L/min |
| Dimensions (W×D×H) | 320×370×670 mm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNX-1500 |
| Type | Orbital Microplate Shaker |
| Timing Range | 0–99 h 59 min or Continuous Mode |
| Speed Range | 300–1500 rpm (300–1000 rpm under full load) |
| Orbit Diameter | 3 mm |
| Platform Capacity | 4 standard microplates (96-well format) |
| Dimensions (W×D×H) | 284 × 264 × 121 mm |
| Weight | 6 kg |
| Drive System | Brushless DC Motor |
| Display | LED Digital Display |
| Alarm | Audible End-of-Timer Alert |
| Compliance | CE-marked for laboratory use in EU |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTC-100 |
| Oscillation Frequency | 300–1800 rpm |
| Oscillation Amplitude | 3 mm (horizontal rotation) |
| Temperature Range | −5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Cooling Rate | ≥7°C/min (100°C → 20°C), ≥1.2°C/min (ambient → ambient −20°C at 30°C ambient) |
| Timer Range | 0–99 h 59 min, multi-step programming |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 8.3 kg |
| Standard Plate | 1 interchangeable module included |
| Optional Modules | A–N series (including 96-well PCR plates, 0.2–50 mL tube formats, deep-well plates, and custom cavities) |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-24S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 25–2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Channel | 0.1–5 mL |
| Number of Simultaneous Samples | 24 |
| Display | 7-inch TFT Touchscreen |
| Data Storage | 20 Preset Protocols |
| Amplitude Control | Auto-compensated |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature, Overpower, and Overtime Protection |
| Cooling Interface | Integrated Low-Temperature Circulating Rack (−5 to 100 °C) |
| Communication Option | RS-232/USB (optional) |
| Footswitch Support | Optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZF1-1 |
| Instrument Type | Darkroom-style |
| Wavelength Options | 254 nm, 302 nm, 365 nm, and White Light |
| UV Filter Area | 20 × 15 cm |
| UV Lamps | 60 W total (dual-band reflective configuration) |
| Input Voltage | 220 V AC, 50 Hz |
| Compliance | CE-marked for laboratory use, conforms to IEC 61010-1 safety standards |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | SPX-80 |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Chamber Volume | 80 L |
| External Dimensions (W×D×H) | 544×544×1000 mm |
| Inner Chamber Material | Mirror-finish Stainless Steel |
| Control System | Microprocessor-based PID Controller with Dual Digital Display |
| Insulation | Double-layer High-efficiency Polyurethane Foam |
| Door | Full Tempered Glass with Large Observation Window |
| Air Circulation | Forced-air Convection via Stainless Steel Ductwork |
| Refrigeration System | Modular Compressor Unit with Delayed Start & High/Low Pressure Protection |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNMTH-100 |
| Instrument Type | Heated Orbital Shaker / Incubating Mixer |
| Timer Range | 0–99 h 59 min, multi-segment programming |
| Oscillation Speed | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (horizontal orbital) |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Temperature Stability | ±0.3 °C |
| Temperature Display Resolution | 0.1 °C |
| Heating Rate | <15 min (20 °C → 100 °C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 6.8 kg |
| Platform | Single interchangeable plate (multiple well-format compatible) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | SHZ-82 |
| Instrument Type | Air-bath constant-temperature orbital shaker |
| Temperature Range | Ambient to 50 °C |
| Temperature Uniformity | ±0.5 °C |
| Oscillation Mode | Orbital |
| Oscillation Frequency | 0–300 rpm |
| Oscillation Amplitude | 20 mm |
| Timer Range | 0–120 min |
| Heating Power | 500 W |
| Number of Platforms | 1 |
| Construction | Stainless steel chamber interior |
| Drive System | Mechanical speed control with smooth, low-vibration transmission |
| Compliance | Designed for GLP-compliant laboratories |