| Model | MINIC-100 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.3 °C |
| Heating Time (25 °C → 100 °C) | ≤20 min |
| Cooling Time (100 °C → 25 °C) | ≤20 min |
| Cooling Time (RT → RT−15 °C) | ≤25 min |
| Block Uniformity | ±0.3 °C |
| Display Resolution | 0.1 °C |
| Timer Range | 1 s–99 min 59 s or ∞ / 1 min–99 h 59 min or ∞ |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Dimensions | 145 × 113 × 140 mm |
| Net Weight | 1.8 kg |
| Safety Certification | CE-compliant |
| Module Options | Mini-A (15 × 2.0 mL), Mini-B (15 × 1.5 mL), Mini-C (24 × 0.5 mL), Mini-D (32 × 0.2 mL) |
| Brand | Hanuo |
|---|---|
| Model | HDKT200-1 |
| Temperature Range | Ambient +5 to 150 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Heating Time | ≤12 min (20 °C to 100 °C) |
| Temperature Uniformity | ≤ ±0.5 °C |
| Module Temperature Deviation @40 °C | 0.3 °C |
| Display Resolution | 0.1 °C |
| Programmable Stages | 5-segment ramp/soak |
| Power Consumption | 200 W |
| Safety Protection | Over-temperature cutoff, fuse (250 V, 3 A, φ5×20), auto-fault detection with audible alarm |
| Brand | Hanuo |
|---|---|
| Model | MINIB-100 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability @100°C | ±0.5°C |
| Temperature Uniformity (Module) | ≤±0.5°C @40°C |
| Display Resolution | 0.1°C |
| Heating Time | ≤15 min (20°C → 100°C) |
| Input Power | 24 V DC |
| Dimensions (L×W×H) | 110 × 156 × 92 mm |
| Net Weight | <1 kg |
| Timer Range | 0–99 h 59 min |
| Over-Temperature Protection | Built-in |
| Calibration Function | Yes |
| Module Compatibility | Interchangeable (MINI-A to MINI-G) |
| Brand | Hanuo |
|---|---|
| Model | HNDTC-100 |
| Temperature Range | -10 °C to 100 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Uniformity (at 40 °C) | ≤0.3 °C |
| Stability at 100 °C | ≤±0.5 °C |
| Display Resolution | 0.1 °C |
| Heating Time (20 °C → 100 °C) | ≤15 min |
| Cooling Time (RT → −30 °C) | ≤30 min (ambient ≤26 °C) |
| Timer Range | 1 min – 99 h 59 min |
| Power Consumption | 150 W |
| Net Weight | 2.2 kg |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Compatible Modules | A–L (standard interchangeable block types for 0.2–50 mL tubes, microplates, and custom configurations) |
| Brand | Hanuo |
|---|---|
| Model | MINIB-100 |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Accuracy | ±0.3°C at 40°C |
| Temperature Uniformity | ≤ ±0.5°C across block |
| Stabilization Time | ≤15 min (20°C → 100°C) |
| Power Input | 24 V DC |
| Power Consumption | 45 W |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Max Overtemperature Protection | 105°C |
| Net Weight | 0.8 kg |
| Dimensions | 125 × 105 × 75 mm (L × W × H) |
| Module Compatibility | 0.2 mL, 0.5 mL, 1.5 mL, 2.0 mL tubes, cuvettes (8–12.5 × 12.5 mm), 15 mL & 50 mL conical tubes |
| Brand | Hanuo |
|---|---|
| Model | MINIC-100I |
| Temperature Range | −10°C to 100°C |
| Temperature Accuracy | ±0.3°C at 37°C |
| Temperature Uniformity | ≤±0.3°C at 37°C |
| Heating/Cooling Time | ≤12 min (25°C ↔ 100°C), ≤25 min (RT → RT−25°C) |
| Heat Lid Range | OFF to +10°C, Accuracy: ±0.5°C |
| Timer Range | 1 sec to 99 h 59 min or continuous |
| Multi-point Programming | Up to 5 setpoints, up to 99 cycles |
| Auto-restart After Power Failure | Yes |
| 4°C Hold Post-Run | Yes |
| Input Power | 150 W |
| Voltage | AC 220 V, 50–60 Hz |
| Dimensions | 300 × 200 × 210 mm |
| Net Weight | 4.7 kg |
| Compliance | CE-marked design |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | MINIB-100 |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Accuracy | ±0.3°C (at 100°C) |
| Temperature Uniformity | ≤ ±0.5°C across block |
| Block Temperature Gradient at 40°C | 0.3°C |
| Heating Time | ≤15 min (20°C → 100°C) |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Power Input | 24 V DC |
| Rated Power | 45 W |
| Net Weight | 0.8 kg |
| Safety Features | Over-temperature protection, self-diagnostic alarm, auto-shutdown |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDKT200-4 |
| Temperature Range | Ambient +5 °C to 130 °C |
| Temperature Accuracy | ±0.5 °C |
| Display Resolution | 0.1 °C |
| Heating Time | ≤12 min (20 °C → 100 °C) |
| Power Consumption | 600 W |
| Dimensions | Not specified |
| Net Weight | 4 kg |
| Module Compatibility | 24–96 well configurations for 0.2–40 mm diameter tubes/vials |
| Safety | Built-in over-temperature protection, fuse (250 V / 3 A), auto-failure detection with audible alarm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HD200 |
| Temperature Range | Ambient to 110 °C |
| Temperature Accuracy | ±0.3 °C (@37 °C) |
| Temperature Uniformity | ±0.2 °C (@37 °C) |
| Heating Time | ≤15 min (25 °C → 100 °C) |
| Dimensions | 370 × 254 × 178 mm |
| Net Weight | 8 kg |
| Power | 500 W |
| Voltage | AC 110/220 V, 50–60 Hz |
| Timer Range | 1 min – 99 h 59 min or ∞ |
| Block Zones | 4 independent zones (A–D) |
| Max Capacity per Zone | up to 96 × 1.5 mL tubes (with compatible block) |
| Display Resolution | 0.1 °C |
| Safety | Dual overtemperature protection (hardware + software), auto-recovery after power interruption, factory-calibrated aluminum blocks |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HNB80 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.3°C |
| Heating Time | ≤6 min (20°C → 56°C) |
| Dimensions | 145 × 113 × 110 mm |
| Net Weight | 0.8 kg |
| Power Supply | AC 110–240 V, 50–60 Hz |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h |
| Module Compatibility | M-A (Φ10 mm, 15 wells), M-B (Φ12 mm, 12 wells), M-C (Φ15 mm, 8 wells), M-D (Φ16 mm, 8 wells), M-E (Φ12 mm conical bottom, 14 wells), M-F (Φ9 mm, 18 wells) |
| Safety | Built-in over-temperature protection, 24 V DC internal power architecture |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HD200 |
| Temperature Range | 0–110 °C |
| Temperature Accuracy | ±0.3 °C (@37 °C) |
| Temperature Uniformity | ±0.2 °C (@37 °C) |
| Heating Time | ≤15 min (25 °C → 100 °C) |
| Dimensions (W×D×H) | 370 × 254 × 178 mm |
| Net Weight | 8 kg |
| Power | 500 W |
| Voltage | AC 110/220 V, 50–60 Hz |
| Timer Range | 1 min – 99 h 59 min or ∞ |
| Block Zones | 4 independent zones with individual timers and status LEDs |
| Display Resolution | 0.1 °C |
| Safety | Dual overtemperature protection (hardware + software), auto-restart after power interruption, factory-calibrated aluminum blocks, built-in temperature calibration function |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDKT200-4 |
| Temperature Range | Ambient +5 to 150 °C |
| Temperature Accuracy | ±0.5 °C |
| Display Resolution | 0.1 °C |
| Heating Time | ≤12 min (20 °C to 100 °C) |
| Block Uniformity | ≤±0.5 °C |
| Module Delta T @40 °C | 0.3 °C |
| Power Rating | 600 W |
| Programmable Stages | 5-segment ramp/soak |
| Safety | Integrated overtemperature cutoff, fuse (250 V, 3 A, Φ5×20 mm), auto-fault detection with audible alarm |
| Brand | Hanuo |
|---|---|
| Model | HNDKT200-2 |
| Temperature Range | Ambient +5 to 150 °C |
| Temperature Accuracy | ±0.5 °C |
| Display Resolution | 0.1 °C |
| Block Uniformity | ≤±0.5 °C |
| Temperature Uniformity at 40 °C | ±0.3 °C |
| Heating Time (20 °C → 100 °C) | ≤12 min |
| Power Rating | 400 W |
| Programmable Stages | 5-segment ramp/soak profile |
| Input Protection | 250 V, 3 A, Ø5×20 mm fuse |
| Control Interface | Touch-sensitive keypad with LCD display |
| Safety Features | Over-temperature cutoff, self-diagnostic alarm, calibration offset adjustment |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDKT200-1 |
| Temperature Range | RT + 5°C to 150°C |
| Temperature Accuracy | ±0.5°C (at 40–100°C), ±1.0°C (at 100–150°C) |
| Temperature Uniformity | ≤ ±0.5°C across block surface |
| Block Temperature Gradient at 40°C | ≤ 0.3°C |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Heating Time | ≤ 30 min (20°C → 150°C) |
| Block Dimensions | 95.5 × 76.5 × 50 mm (standard modules) |
| Weight | Not specified |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDTC-100 |
| Temperature Range | -10 °C to 100 °C |
| Temperature Accuracy | ±0.5 °C @ 100 °C |
| Temperature Uniformity | ≤±0.3 °C @ 40 °C |
| Module Temperature Gradient | 0.3 °C @ 40 °C |
| Display Resolution | 0.1 °C |
| Heating Time | ≤15 min (20 °C → 100 °C) |
| Cooling Time | ≤20 min (RT → −25 °C, ambient 30 °C) / ≤30 min (RT → −30 °C, ambient 25 °C) |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 2.2 kg |
| Timer Range | 1 sec – 99 h 59 min |
| Programmable Steps | Up to 5 temperature/time segments |
| Safety Features | Over-temperature protection, self-diagnostic error detection with audible alarm, temperature offset calibration |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNESC1000 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.3 °C (at 37 °C) |
| Heating Time | ≤12 min (25 °C → 100 °C) |
| Cooling Capability | −10 °C to 100 °C (refrigerated variant) |
| Thermal Lid Range | OFF to +10 °C |
| Thermal Lid Accuracy | ±0.5 °C |
| Dimensions | 300 × 200 × 210 mm |
| Net Weight | 4.7 kg |
| Power Input | AC 220 V, 50–60 Hz |
| Rated Power | 150 W |
| Timer Range | 1 s to 99 h 59 min or ∞ |
| Multi-point Programming | 5 setpoints, up to 99 cycles |
| Auto-restart after Power Failure | Yes |
| 4 °C Hold Post-Run | Yes |
| Calibration | User-accessible temperature offset adjustment per module type |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDKT200-2 |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Accuracy | ±0.5°C |
| Display Resolution | 0.1°C |
| Heating Time | ≤12 min (20°C to 100°C) |
| Block Uniformity | ≤±0.5°C @40°C |
| Power Consumption | 400 W |
| Dimensions (W×D×H) | 200×220×110 mm |
| Net Weight | 3 kg |
| Programmable Stages | Up to 5 segments |
| Timer Range | 1 min – 99 h 59 min |
| Safety | Built-in overtemperature protection, fuse (250 V, 3 A, Ø5×20 mm), auto-failure detection with audible alarm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDKT200-2 |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Accuracy | ±0.5°C (at 40–100°C) |
| Temperature Uniformity | ≤±0.5°C across block surface |
| Block Temperature Gradient at 40°C | ≤0.3°C |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Heating Time | ≤30 min (20°C → 150°C) |
| Net Weight | 2 kg |
| Dimensions (W×D×H) | 95.5 × 76.5 × 50 mm (standard block) |
| Safety Features | Over-temperature protection, self-diagnostic error detection with audible alarm, calibration offset adjustment |
| Brand | Hanuo |
|---|---|
| Model | HNES1000 |
| Temperature Range | −10 °C to 100 °C |
| Temperature Accuracy | ≤ ±0.5 °C (at setpoint) |
| Heating Time | ≤12 min (25 °C → 100 °C) |
| Cooling Capability | Yes (down to −10 °C) |
| Heated Lid Range | OFF to +10 °C |
| Heated Lid Accuracy | ≤ ±0.5 °C |
| Multi-Point Programming | Up to 5 temperature/time segments, up to 99 cycles |
| Timer Range | 1 s to 99 h 59 min or continuous operation |
| Display Resolution | 0.1 °C |
| Temperature Uniformity | ≤ ±0.3 °C at 37 °C |
| Input Power | 150 W |
| Voltage | AC 220 V, 50–60 Hz |
| Dimensions (W×D×H) | 300 × 200 × 210 mm |
| Net Weight | 4.0 kg |
| Compliance | CE-marked design principles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDTH-100G |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.3°C |
| Heating Time | ≤15 min (20°C to 100°C) |
| Dimensions | 270 × 190 × 170 mm |
| Net Weight | 2.2 kg |
| Module Capacity | 6 × 50 mL centrifuge tubes |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Power | 150 W |
| Temperature Uniformity | ≤±0.3°C at 40°C |
| Over-Temperature Protection | Built-in dual-stage safety cutoff |
| Calibration Offset Adjustment | Yes |
| Control Interface | LCD touchscreen with real-time digital display |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model Series | HNDKT200 |
| Temperature Range | RT+5°C to 150°C |
| Temperature Accuracy | ±0.5°C |
| Heating Time | ≤12 min (20°C → 100°C) |
| Display Resolution | 0.1°C |
| Block Uniformity | ±0.5°C |
| Module Delta-T at 40°C | 0.3°C |
| Power Rating | 400 W |
| Dimensions | L×W×D (mm) |
| Net Weight | 3 kg |
| Control Interface | Touch Key + LCD |
| Programmability | 5-Stage Ramp/Soak Profiles |
| Safety | Dual Over-Temperature Protection, Fuse (250 V, 3 A, Φ5×20 mm) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HNDTH-100 |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.1°C (display resolution) |
| Temperature Stability @100°C | ≤±0.5°C |
| Block Uniformity @40°C | ≤±0.3°C |
| Heating Time | ≤15 min (20°C → 100°C) |
| Dimensions | 270 × 190 × 170 mm |
| Net Weight | 2.2 kg |
| Power | 150 W |
| Timer Range | 0–99 h 59 min |
| Standard Block | 35 × 2.0 mL tubes |
| Programmable Steps | Up to 5 temperature/time segments |
| Display | LCD with touch keys |
| Safety | Over-temperature protection, self-diagnostic alarm, calibration offset adjustment |