- All
- Favorite
- Popular
- Most rated
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000D |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 50–1000 W (continuously adjustable) |
| Operating Frequency | 20–30 kHz (auto-tuned, LCD-displayed) |
| Temperature Control Range | −5 to 100 °C (optional −120 to 300 °C) |
| Sample Volume Capacity | 50–600 mL (glass double-jacketed reactors: 50 / 100 / 250 / 500 mL) |
| Stirring Speed | 0–2400 rpm (magnetic, continuously adjustable) |
| Horn Diameter | Φ10 mm or Φ12 mm (titanium alloy, immersion-type) |
| Pulse Mode | Independent on/off control, adjustable pulse duration and automatic pulse counting |
| Sealing Interface | Standard ground-glass joints (e.g., 24/24, 50/50), custom configurations available |
| Cooling/Heating Medium | Circulating water or thermal oil via jacket |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-1000 |
| Ultrasonic Output Power | 1000 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | –5 °C to 100 °C (with optional chiller) |
| Maximum Sample Volume | 1000 mL |
| Pulse Mode Interval | 0.1–99.9 s adjustable |
| Total Processing Time | 0–99 h 59 min 59 s |
| Programmable Memory | 20 user-defined protocols |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Touchscreen Interface | 4.3″ TFT LCD |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Compliance | CE-marked design principles |
| Brand | Daxluot |
|---|---|
| Model | Dxluot-4SKI |
| Origin | Shanghai, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 12–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume per Channel | 1–10 mL |
| Number of Simultaneous Samples | 4 |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated |
| Programmable Parameters | 20 user-defined protocols |
| Ultrasound On/Off Time | 0.1–99.9 s (adjustable) |
| Total Cycle Duration | 0.1 s – 99 h 59 min 59 s |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Data Logging | Timestamped protocol execution history |
| Cooling Integration | Integrated Peltier-assisted cold block with recirculating thermal management |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | Hannuo-950EW |
| Ultrasonic Power | 950 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–700 mL (with interchangeable probes) |
| Probe Diameter (Standard) | Φ6 mm |
| Pulse Mode | 0.1–99.9 s ON/OFF adjustable |
| Duty Cycle | 0.1–99.9% |
| Power Adjustment Range | 1–99% (10–950 W) |
| Display | 7-inch TFT touch screen |
| Data Storage | 20 user protocols |
| Communication Interface | RS-232/USB for PC connectivity |
| Safety Features | Overtemperature, overload, no-load, and self-diagnostic alarms |
| Optional Accessories | Cryogenic cooling module, motorized probe lift, acoustic isolation chamber |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-8S |
| Ultrasonic Power | 20–2000 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 8 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic Load-Compensated |
| Data Storage | 20 Preset Protocols |
| Display | 7-inch TFT Touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-4SKII |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 18–1800 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 4 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Safety Protections | Overtemperature, over-power, and overtime cutoffs |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Cryogenic Compatibility | Integrated Peltier-cooled sample rack with external chiller port |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Frequency | 20 kHz |
| Maximum Ultrasonic Power | 1200 W |
| Temperature Range | 0–99 °C |
| Sample Volume per Tube | 0.1–2 mL |
| Number of Simultaneous Samples | 4 or 6 |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Cooling Interface | Yes (for external chiller connection) |
| Display | Large LCD |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-24S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 25–2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Channel | 0.1–5 mL |
| Number of Simultaneous Samples | 24 |
| Display | 7-inch TFT Touchscreen |
| Data Storage | 20 Preset Protocols |
| Amplitude Control | Auto-compensated |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature, Overpower, and Overtime Protection |
| Cooling Interface | Integrated Low-Temperature Circulating Rack (−5 to 100 °C) |
| Communication Option | RS-232/USB (optional) |
| Footswitch Support | Optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IIIB |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 3500 W |
| Operating Frequency | 19–30 kHz |
| Temperature Range | −5 °C to 100 °C (expandable with external chiller) |
| Sample Volume per Tube | 0.1–2 mL |
| Parallel Sample Capacity | 4–32 tubes |
| Display & Control | Touchscreen Interface |
| Communication Options | RS232/RS485 port (optional) |
| Cooling Interface | Integrated water-circulation coupling port (chiller compatible) |
| Duty Cycle | 1–99.9% adjustable |
| Power Supply | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN-1000Y |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1000 W |
| Operating Frequency | 22 kHz |
| Temperature Range | 0–99 °C |
| Sample Volume Capacity | 1000 mL |
| Sample Throughput | Single-sample operation |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Dalxuot-300M |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 28–30 kHz |
| Ultrasonic Power Output | 30–300 W (adjustable) |
| Sample Volume Capacity | 0.1–300 mL |
| Sample Throughput | Single-sample processing |
| Input Power | 100–230 V AC, 50–60 Hz or 12–24 V DC |
| Weight | 0.5 kg |
| Dimensions (L×W) | 300 × 43 mm |
| Transducer Material | 7075 Aluminum Alloy |
| Horn Material | TC4 Titanium Alloy |
| Housing Material | ABS + Flame-Retardant Additive |
| Operating Temperature | 5–30 °C |
| Relative Humidity | ≤70% RH |
| Standard Probe Diameter | Ø6 mm |
| Optional Probes | Ø2 mm (0.1–5 mL), Ø6 mm (5–100 mL), Ø8 mm (50–300 mL) |
| Continuous Sonication Duration | <40 min |
| Control Mode | Manual push-button activation (momentary contact) |
| Display | DC input voltage only |
| Optional Accessory | Adjustable transducer support stand (300 × 225 × 320 mm) |
| Brand | Hanuo |
|---|---|
| Model | HN-3000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 3000 W |
| Operating Frequency | 20–25 kHz with Automatic Frequency Tracking |
| Sample Volume Capacity | 1000 mL |
| Temperature Control Range (Optional) | −5 °C to 100 °C |
| Programmable Storage | 20 Presets |
| Display | 4.3″ TFT Touchscreen |
| Pulse Mode Interval | 0.1–99.9 s Adjustable |
| Optional Accessories | Circulating Chiller, Magnetic Stirrer, Dual-Layer Thermostatic Reactor Vessels (50–2000 mL), Replaceable Horn Probes (Φ28 mm to Φ35 mm and Multi-Stage Extended Configurations) |
| Brand | Hanuo |
|---|---|
| Model | HN-2500 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume Capacity | 1000 mL |
| Temperature Control Range | Ambient to 90 °C (optional extended range: −5 °C to 100 °C with chiller) |
| Pulse Mode Interval | 0.1–99.9 s (adjustable) |
| Total Processing Time | 0–99 h 59 min 59 s |
| Data Storage | 20 programmable protocols |
| Probe Material | Ti-6Al-4V titanium alloy |
| Input Voltage | AC 220 V ±5%, 50 Hz |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN99-IIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1800 W |
| Operating Frequency | 19–23 kHz |
| Temperature Range | 0–90 °C |
| Sample Volume Capacity | 1500 mL |
| Number of Samples per Run | 1 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Hannuo-6000 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Output Power | 6000 W |
| Operating Frequency | 19 kHz (frequency-tracking) |
| Sample Volume Capacity | 5 L (continuous flow) |
| Temperature Control Range | 0–100 °C |
| Pulse Duration | 0.1–99.9 s (ultrasonic/on–off interval) |
| Total Process Time | 0–99 h 59 min 59 s |
| Display | 4.3-inch TFT touchscreen |
| Protection | Overload, overtemperature, and fault auto-detection |
| Power Supply | AC 220 V ±5%, 50 Hz (110 V optional) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HN98-IIID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1200 W |
| Operating Frequency Range | 19–23 kHz |
| Temperature Control Range | 0–90 °C |
| Maximum Sample Volume | 1000 mL |
| Sample Throughput | Single-sample batch processing |
| Transducer Material | Titanium alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated adjustment |
| Display | Backlit LCD with real-time parameter monitoring |
| Data Storage | 50 programmable protocols |
| Safety Features | Overtemperature alarm, frequency tracking failure detection, acoustic enclosure with certified sound attenuation (>35 dB reduction at 1 MHz) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-400 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 4–400 W (adjustable in 1% increments) |
| Operating Frequency | 19–25 kHz |
| Temperature Range | Ambient to 90 °C (optional low-temperature circulator support up to 100 °C) |
| Sample Volume Capacity | 0.1–300 mL (dependent on horn probe selection) |
| Probe Options | Φ2, Φ3, Φ5, Φ6, Φ8 mm titanium alloy horns |
| Display | 4.3-inch true-color capacitive touchscreen |
| Control System | Embedded microcontroller with TFT touch interface |
| Data Storage | 20 programmable protocols |
| Safety Features | Overload, no-load, overtemperature, and time-out alarms |
| Power Supply | 220 V / 110 V, 50 / 60 Hz |
| Optional Accessories | Cooling jacket, acoustic isolation chamber, foot switch, RS232/USB data export, thermal printer |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-IB |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Tube | 0.2 / 0.5 / 1.5 / 2.0 mL |
| Sample Capacity | 4 or 6 tubes simultaneously |
| Duty Cycle | 1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Display | Large LCD (touchscreen optional) |
| Cooling Interface | Optional water-circulation port for external chiller |
| Communication | RS232/RS485 optional |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN96-II |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 10–150 W |
| Operating Frequency | 20–25 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 0.2–150 mL |
| Number of Samples per Run | 1 |
| Standard Probe Diameter | Φ6 mm |
| Optional Probe Diameters | Φ2, Φ3, Φ8, Φ10 mm |
| Duty Cycle | 1–99.9% |
| Integrated Temperature Monitoring & Control | Yes |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Microprocessor-Controlled Operation | Yes |
| Adjustable Amplitude with Load Compensation | Yes |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN98-IIB |
| Instrument Type | Cup-Horn Ultrasonic Cell Disruptor |
| Ultrasonic Power | 2500 W |
| Operating Frequency | 19 kHz |
| Sample Volume per Tube | 0.1–2 mL |
| Maximum Simultaneous Samples | 8 |
| Temperature Control | Ambient (with optional external chiller interface) |
| Duty Cycle Range | 1–99.9% |
| Input Voltage | 220 V / 50 Hz (standard) |
| Compliance | CE-marked design principles |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN98-IIIDL |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 1200 W |
| Operating Frequency | 20 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Volume Capacity | 1000 mL |
| Sample Throughput | Single sample per cycle |
| Brand | Hanuo |
|---|---|
| Model | HN92-IID |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 20–900 W (adjustable) |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | Ambient to 90 °C |
| Maximum Sample Volume | 1000 mL |
| Probe Diameter | Φ6 mm or Φ10 mm (included) |
| Duty Cycle | 1–99.9% |
| Sample Capacity Range | 0.2–600 mL |
| Temperature Protection Threshold | ≤90 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Control System | Microprocessor-Based with Digital Interface |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-500 |
| Ultrasonic Output Power | 500 W |
| Operating Frequency | 20–25 kHz |
| Temperature Control Range | −5 to 100 °C |
| Maximum Sample Volume | 500 mL |
| Probe Material | Titanium Alloy (Grade 5) |
| Control Interface | 4.3″ TFT Touchscreen |
| Programmable Memory | 20 Presets |
| Pulse Mode Interval | 0.1–99.9 s Adjustable |
Show next