Empowering Scientific Discovery

Shanghai Huantong Education & Scientific Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR (Huantong NMR)
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelGY-CTNMR-10
PriceUpon Request
Magnetic Field Strength0.45 T (nominal)
¹H Resonance Frequency19.1 MHz
Magnet Pole Diameter100 mm
Field Homogeneity0.8 ppm over Ø5 mm DSV
Sample Diameter Limit<10 mm
Image Matrix128×128 (standard), up to 512×512 (interpolated)
Temperature Stability±0.06 K over 2 h (post-warmup)
RF Frequency Tuning Range10–20 MHz
Resolution1 Hz
RF Coil OptionsStandard 10 mm birdcage coil
Pulse Sequence CapabilitiesProgrammable, including spin echo, inversion recovery, gradient echo, frequency/phase-encoded 2D imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR (Huanton NMR)
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic Benchtop NMR
ModelGY-PNMR12-6
Price RangeUSD 70,000 – 140,000
Instrument TypeLow-Field Pulsed Fourier Transform NMR Spectrometer
Sample FormLiquid Solutions Only
Operating Frequency60 MHz (¹H resonance)
Excitation MethodPulsed Fourier Transform (PFT-NMR)
Sensitivity10,000:1 (S/N ratio, CH₃ signal of 98% ethanol, 32 scans)
Resolution≤ 0.03 ppm (full width at half maximum, FWHM, in ¹H spectrum of CHCl₃ in CDCl₃)
Quantitative Reproducibility (¹H)< 1% RSD (relative standard deviation, n = 10)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuatong NMR (HTNMR)
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryPreclinical MRI System
Animal ModelRat
Magnetic Field Strength1.2 T ±0.05 T
Proton Resonance Frequency51 MHz ±2 MHz
Magnet Pole Diameter300 mm
Effective Imaging Volume (Coil Bore)Φ50 mm × H80 mm
Field Homogeneity<8 ppm over 50 mm × 50 mm × 80 mm DSV
Spatial Resolution (in-plane)0.08 mm (measured on 0.05 mm water phantom)
Gradient Strength10 G/cm (100 mT/m)
Max Gradient Amplitude200 mT/m (X/Y/Z)
Image MatrixUp to 256 × 256 × 128
Image Linearity>98% in X/Y/Z (50 mm × 50 mm × 80 mm)
Temperature Stability±0.005 °C chamber control, 1 m°C display resolution
Field Drift<100 Hz/h (Larmor frequency drift)
Data FormatDICOM-compliant export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHT-MRSI60-50 Series
Instrument TypePreclinical Magnetic Resonance Imaging System
Animal ModelMouse (also compatible with rat and small biological specimens)
Spatial Resolution (in vivo)0.15 mm (standard), down to 0.08 mm (high-resolution mode)
Field Strength1.5 T (permanent magnet)
Bore DiameterΦ50 mm × H80 mm
Maximum Sample Depth50 mm
Image Matrix Options128×128×128 (standard), 256×256×128 (high-res), 512×512×128 (ultra-high-res)
Nuclei Supported¹H, ¹⁹F, ³¹P
Magnetic Field Homogeneity≤8 ppm over DSV 30 mm
Field Stability≤100 Hz/h frequency drift
ShieldingIntegrated self-shielding (no external RF or magnetic shielding required)
Cryogen-FreeYes (permanent magnet design)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
ManufacturerHTNMR (Huantong NMR)
ModelHT-3DNMR-25
Instrument TypeBenchtop Permanent-Magnet MRI System
Field Strength0.45–0.5 T
¹H Resonance Frequency18–22 MHz
Bore Diameter150 mm
Effective Imaging Volume (FOV)25 mm × 25 mm × 25 mm
Gradient Strength10 G/cm (max 70 mT/m per axis)
Spatial Resolution (isotropic)0.08 mm (high-res mode)
Image MatrixUp to 256 × 256 × 128
Magnetic Homogeneity< 8 ppm over 25 mm DSV
Temperature Stability±0.06 K/h (after 2 h warm-up)
Field Drift≤100 Hz/h (Larmor frequency)
Linearity>98% in X/Y/Z over 20 mm DSV
RF Probe ID25 mm diameter solenoid or saddle coil
Sample CompatibilityLive mice (≥4 weeks), plant tissues, insects, hydrogels, food samples, polymer phantoms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Region of OriginDomestic (China)
ModelHT-MRSI60-35
Instrument TypeMagnetic Resonance Imaging (MRI) System
Animal SpeciesMouse (also compatible with rat and small plant specimens)
Maximum Sample Diameter35 mm
Maximum Sample Height50 mm
Spatial Resolution0.08 mm (high-resolution mode)
Field Homogeneity≤ 8 ppm over DSV 20 mm
Field StabilityFrequency drift ≤ 100 Hz/h
Imaging Matrix Options128×128×128 (standard), 256×256×128 (high-res), 512×512×128 (ultra-high-res)
Multi-nuclear Capability¹H, ¹⁹F, ³¹P
Magnet TypePermanent Magnet (1.5 T)
Cryogen-FreeYes
Passive ShieldingIntegrated self-shielding design
RF Coil ConfigurationTunable multi-nuclei volume coil (standard)
Number of Simultaneous Samples1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeHigh-Field Benchtop NMR Spectrometer
Sample FormLiquid
Operating Frequency90 MHz (¹H)
Data Acquisition MethodPulsed Fourier Transform (PFT-NMR)
Sensitivity10,000:1 (S/N, CH₃ peak of 98% ethanol, 32 scans)
Resolution0.5 Hz (0.011 ppm at 90 MHz)
Magnet SystemPermanent Rare-Earth Magnet (No Cryogen Required)
Nuclei Supported¹H, ¹³C, ¹⁹F, ³¹P (software-selectable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypePreclinical MRI Scanner
Sample CompatibilitySolid & Liquid Samples (In Vivo & Ex Vivo)
Sensitivity52 dB
Spatial Resolution0.05 mm (Isotropic, Water Phantom Standard)
Magnetic Field Strength1.2 T ± 0.05 T
Proton Resonance Frequency51 MHz ± 2 MHz
Magnet Bore Diameter300 mm
Effective Imaging VolumeΦ50 mm × H75 mm
Magnetic Homogeneity<8 ppm over 50 mm × 50 mm × 70 mm DSV
Gradient Strength100 mT/m (X/Y/Z)
Image MatrixUp to 256 × 256 × 128
Linearity>98% in X/Y/Z (50 mm × 50 mm × 75 mm FOV)
Temperature Stability±0.005 °C (Cavity Control), Display Resolution: 1 m°C
Field Drift<100 Hz/h (Larmor Frequency)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
ModelHT-LFMR
Field Strength< 0.5 T
Animal CompatibilityMouse (in vivo)
Maximum Sample Penetration Depth60 mm
Bore Diameter Options40 mm / 60 mm
Operating Temperature RangeCustomizable (Low-Temp & High-Temp Options Available)
Primary Measurement ParametersT₁ Relaxation Time, T₂ Relaxation Time, Diffusion Coefficient (D)
Application DomainNon-Destructive Quantitative Analysis of Water Distribution, Oil Content, Seed Viability, Food Quality, and Biomaterial Microstructure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
ManufacturerHTNMR Scientific Equipment Co., Ltd.
Instrument TypeMagnetic Resonance Imaging (MRI) System
Animal ModelRat (also compatible with mouse)
Spatial Resolution0.15 mm
Field of View (FOV)50 mm
Matrix Sizes128×128×128 (standard), 256×256×128 (high-resolution), 512×512×128 (ultra-high-resolution)
Maximum Sample Depth50 mm
Sample Capacity1 animal per scan
Magnet TypePermanent magnet (cryogen-free)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelHT-AMNMR-50
Instrument TypeBenchtop Permanent-Magnet MRI System
Animal Model CompatibilityRat
Magnetic Field Strength0.3–0.54 T
¹H Resonance Frequency18–23 MHz
Magnet Bore Diameter250 mm
Sample ApertureΦ50 mm
Magnetic Field Homogeneity<8 ppm over 45×45×45 mm³
Image Matrixup to 256×256×128
Spatial Resolutiondown to 0.08 mm (isotropic)
Temperature Stability±0.06 K/h (after 2-h warm-up)
Field Drift≤100 Hz/h (Larmor frequency)
Maximum Gradient Strength70 mT/m (X/Y/Z)
Image Linearity>98% over 50×50×50 mm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeMagnetic Resonance Imaging (MRI) System
Animal Model CompatibilityRat, Mouse
Field of View (FOV)50 mm diameter × 80 mm height
Maximum Sample DiameterΦ50 mm
Detection Depth50 mm
Spatial Resolution0.15 mm (standard mode), 0.08 mm (high-resolution mode)
Image Matrix Options128×128×128, 256×256×128, 512×512×128
Magnetic Field Homogeneity≤8 ppm over 20 mm DSV
Field StabilityFrequency drift ≤100 Hz/h
Multi-Nucleus Capability¹H, ¹⁹F, ³¹P
Magnet TypePermanent Magnet (1.5 T)
Cryogen-Free OperationYes
Passive ShieldingIntegrated self-shielding design
ComplianceDesigned for GLP-compliant preclinical research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelHT-MRSI60-25
Instrument TypeMagnetic Resonance Imaging (MRI) & Magnetic Resonance Spectroscopic Imaging (MRSI) System
Spatial Resolution0.8 ppm (chemical shift resolution)
Field of View (FOV)25 mm × 30 mm
Magnetic Field Strength1.5 T
¹H Resonance Frequency55–59 MHz
Homogeneity<2 ppm over 25 mm DSV
Temperature Stability±0.06 K/h after 2-h warm-up
SNR55 dB
Geometric Distortion<1%
Image MatrixUp to 512 × 512 (2D), 128 × 128 × 128 (3D), 64 × 64 × 64 × 64 (4D MRSI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHTNMR
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypePreclinical Magnetic Resonance Imaging (MRI) System
ModelHT-MRSI40-60KY
Magnetic Field Strength1.0 T ± 0.05 T
Proton Larmor Frequency42 MHz ± 2 MHz
Magnet Bore Diameter300 mm
Effective Sample Volume (RF Coil)Φ60 mm × H80 mm
Spatial Resolution (Max)0.05 mm (measured with 0.05 mm water phantom)
Gradient Strength100 mT/m (X/Y/Z)
Field Homogeneity< 8 ppm over 50 mm × 50 mm × 80 mm DSV
Image Linearity> 98% in X/Y/Z (50 mm × 50 mm × 80 mm)
Temporal Stability< 100 Hz/h Larmor frequency drift
Temperature Control Stability±0.005 °C (cavity), display resolution 1 m°C
Image MatrixUp to 256 × 256 × 128
DICOM ComplianceYes
Sensitivity52 dB
Resolution98%
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0