- All
- Favorite
- Popular
- Most rated
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | S200 TUr |
| Instrument Type | Online |
| Turbidity Range | 0–10 NTU and 0–100 NTU |
| Measurement Principle | Nephelometric (90° scattered light, ISO 7027 compliant) |
| Resolution | 0.0001 NTU (0–10 NTU range) |
| Accuracy | ±2% of reading or ±0.02 NTU (0–40 NTU) |
| Response Time | 5–500 s |
| Sample Temperature Range | 1–50 °C |
| Operating Pressure Range | 104–1380 kPa (15–200 psi, factory-set default 15 psi) |
| Flow Rate | 100 mL/min–1 L/min |
| Analog Output | 4–20 mA (galvanically isolated, max. load 600 Ω) |
| Digital Interface | RS485 Modbus RTU |
| Relay Outputs | 2 configurable (NO/NC/C, 120–240 VAC, 2 A) |
| Power Supply | 100–240 VAC, 47–63 Hz, 80 VA |
| Display | 4×20-character backlit alphanumeric LCD |
| Enclosure Rating | IP66 |
| Weight | 2.5 kg |
| Environmental Limits | Indoor use only |
| Compliance | ISO 7027, CE, ETL Listed to UL 61010-1, CSA C22.2 No. 1010-1 |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | 575 MP1 |
| Instrument Type | Portable |
| Temperature Range | –5 to +50 °C (optional: –5 to +70 °C) |
| pH Range | 0–14 |
| Conductivity Range | 0–200,000 µS/cm |
| Water Level Range | 0–100 m |
| Accuracy (Level) | <0.05% FS |
| Accuracy (Temp) | <0.1 °C |
| Accuracy (Conductivity) | <0.5% of reading, min. 2 µS/cm |
| Accuracy (pH) | <0.02 |
| Resolution (Level) | 1 cm (standard), 1 mm (optional) |
| Resolution (Temp) | 0.1 °C (standard), 0.01 °C (optional) |
| Resolution (Conductivity) | 0.0005% FS |
| Resolution (pH) | 0.01 |
| Long-term Stability (Level) | <0.05%/year |
| Long-term Stability (Temp) | <0.02 °C/year |
| Cable Length | up to 500 m |
| Probe Depth Rating | 100 m |
| Housing Material | 316 stainless steel & titanium alloy |
| IP Rating | IP68 |
| Power | Internal rechargeable Li-ion battery (rated for ~3 million measurements at 2-min interval ≈ 10 years) |
| Memory | 4 MB flash storage |
| Interfaces | RS-232, USB |
| Pressure Compensation | Integrated barometric compensation tube |
| Cable | 6 mm flexible UV-resistant PUR jacket with Kevlar reinforcement |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | 575-LTC |
| Instrument Type | Portable |
| Temperature Range | –5 to +50 °C (optional –5 to +70 °C) |
| Conductivity Range | 0–200,000 µS/cm |
| Water Level Range | 0–300 m |
| Accuracy (Water Level) | <0.05% FS |
| Accuracy (Temperature) | <0.1 °C |
| Accuracy (Conductivity) | <0.5% of reading (min. 2 µS/cm) |
| Resolution (Water Level) | 1 cm (optional 1 mm) |
| Resolution (Temperature) | 0.1 °C (optional 0.01 °C) |
| Resolution (Conductivity) | 0.0005% FS |
| Long-term Stability (Water Level) | <0.05%/year |
| Long-term Stability (Temperature) | <0.02 °C/year |
| Battery Life | ~3 million measurements (~10 years at 2-min interval) |
| Memory | 4 MB Flash |
| Cable Length | up to 500 m (optional) |
| Probe Depth Rating | 300 m |
| Housing Material | 316 stainless steel & titanium alloy |
| Ingress Protection | IP68 |
| Interface | RS-232, USB |
| Data Formats | HT-Standard, Excel (.xlsx), *.zrxp, Labdüs (*.lgd), *.uvf |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | 120-LTC |
| Instrument Type | Portable |
| Temperature Range | −20 °C to +75 °C |
| Conductivity Range | 0 to 200 mS/cm |
| TDS Calculation | Yes (ppm, user-selectable or standard seawater factor) |
| Sensor Diameter | <25.4 mm (1 inch) |
| Cable Length Options | 15–100 m (aluminum frame) or 120–500 m (acrylic tripod) |
| Display | Backlit LCD with simultaneous real-time readout of level, temperature, conductivity, and TDS |
| Power | 4 × 1.5 V C-cell alkaline batteries (~180 h operation) |
| IP Rating | Sensor IP68, Handheld Unit IP64 |
| Sensor Material | 316 stainless steel & titanium alloy |
| Accuracy | Temperature < ±0.1 °C |
| Temp Compensation Modes | DIN EN 27888 (25 °C ref), user-defined %/°C coefficient, or none |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-pH |
| Instrument Type | Online |
| pH Range | 2–11 (standard) |
| Resolution | 0.01 pH |
| Accuracy | ±0.05 pH |
| Supply Voltage | 9.5–18 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø30 mm × 250 mm |
| Pressure Rating | 600 dbar |
| Electrode Integration | Integrated glass + reference electrode in single housing |
| Membrane Design | Dual-junction diaphragm |
| Operating Depth | Up to 6000 m |
| Temperature Sensor | Not integrated |
| Compliance | Designed for ISO 10523, ASTM D1293, and marine GLP-compliant in-situ deployments |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-EC7 |
| Instrument Type | Online |
| Conductivity Ranges | 0–1 mS/cm |
| Outer Diameter | 40 mm |
| Total Length | ~270 mm |
| Weight | ~300 g |
| Housing Material | Titanium |
| Pressure Rating | 6000 m (6000 dbar) |
| Output Signal | 0–2.5 V DC or 0–5 V DC |
| Supply Voltage | 9–18 V DC |
| Connector | SubConn wet-mateable underwater connector |
| Measurement Principle | Seven-electrode AC conductivity with quartz-glass sensing tube |
| Channels | 4 measurement electrodes + 1 excitation + 2 guard/ground electrodes |
Show next