Empowering Scientific Discovery

Shanghai Yifeng Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBertin
OriginFrance
ModelCoriolis® μ
Sampling PrincipleWetted-Wall Cyclonic Impaction
Flow Rate Range100–300 L/min
Flow Measurement Accuracy±2%
Sampling Duration1–10 min (standard)
Operating Temperature0–50 °C
Operating Relative Humidity≤95% RH
Cut-Off Diameter (d₅₀)<0.5 µm
Biological Collection Efficiency (Staphylococcus epidermidis ATCC 14990)78%
Collection Volume10–15 mL (fixed at 15 mL for standard operation)
Battery Runtime~1 h (internal Li-ion)
Dimensions22 × 33 × 36 cm
Weight3.0 kg (instrument only, with battery)
CertificationsISO 14698-1 validated (UK HPA), CE, UL, CEM
DecontaminationHydrogen Peroxide (H₂O₂)-compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBertin
OriginFrance
ModelCoriolis C
Sampling PrincipleDynamic Cyclonic Separation
Flow Rate50 LPM
Flow Accuracy±2%
Maximum Sampling Duration8 h
Operating Temperature5–45 °C
Operating Relative Humidity10–90% RH
Collection Size Range0.5–10 µm
Dimensions255 × 135 × 130 mm
Weight1.4 kg
Sample Output FormatDry Concentrate in Collection Liquid (e.g., PBS, TE Buffer)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTisch
OriginUSA
ManufacturerTisch Environmental, Inc.
ModelTE-BC251
Sampling PrincipleInertial Impaction via Multi-Stage Cyclonic Separation
Nominal Flow Rate3.5 L/min
Cut-Point Diameters (aerodynamic)Stage 1: 4.9 µm, Stage 2: 1.7 µm, Stage 3: <0.4 µm
ComplianceDesigned to NIOSH BC 251 Protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBertin
OriginFrance
ModelCoriolis+
Sampling PrincipleWet-wall cyclonic separation
Flow Rate Range100–300 L/min (adjustable in 50 L/min increments)
Sampling Duration1–10 min standard
Collection Volume10–15 mL (fixed at 15 mL for consistency)
Cut-Off Diameter (d₅₀)≈0.5 µm
Biological Collection Efficiency78% for *Staphylococcus epidermidis* ATCC 14990
Power SupplyInternal rechargeable Li-ion battery (≈2 h runtime)
Dimensions22 × 33 × 36 cm
Weight2.8 kg (unit only)
CertificationISO 14698-1 validated (UK HPA), CE, UL, CEM
DecontaminationHydrogen peroxide (H₂O₂)-compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTisch
OriginUSA
ModelTE-10-800
Sampling PrincipleInertial Impaction
Flow Rate28.3 L/min
Operating Humidity Range0–95% RH (non-condensing)
Stage Configuration6-stage cascade impactor with defined aerodynamic cut-points