Empowering Scientific Discovery

Shanghai Yifeng Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCerexMS
OriginUSA
ModelShepherd
Instrument PrincipleInfrared Absorption Spectroscopy (FTIR)
TypePortable
Response Time<1 s
RepeatabilityHigh for all IR-active species
Detection RangeSub-ppb to % v/v
Gas Library385+ compounds (including >100 HAPs)
Optical Path Length20 m (fixed, multipass)
DetectorLiquid-nitrogen-free cryogenically cooled MCT
Data OutputRaw interferograms, calibrated spectra, concentration time-series, CSV export
ComplianceDesigned for EPA Method 320 / ASTM D6348 / ISO 12039 alignment
SoftwareCMS Continuous Monitoring Software (Windows Embedded, touchscreen UI)
ConnectivityWi-Fi, Ethernet, USB
Alarm OptionsVisual, audible, email, remote notification
CalibrationBuilt-in reference cell + user-definable multi-point calibration
MaintenanceTwo consumables only — IR source and thermoelectric cooler compressor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandProtea
OriginUnited Kingdom
ModelAtmosFIRt
Instrument PrincipleInfrared Absorption Spectroscopy
TypePortable Multicomponent Gas Analyzer
Response Time (T90)120 s (at 1 cm⁻¹ resolution)
Repeatability<1% of full scale
Spectral ResolutionAdjustable from 0.5 cm⁻¹ to 8 cm⁻¹ (standard: 1, 2, 4, 8 cm⁻¹)
Spectral Range485–8500 cm⁻¹
Detection Limits<0.2 ppm (gas-dependent)
Operating TemperatureUp to 180 °C (sample cell)
Weight21 kg (configurable)
Power100–250 V AC, 50–60 Hz, 250 W typical
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCerexMS
OriginUSA
Model VariantsMini Hound-FR (8.5 m optical path), Hound-FR (17 m optical path), Micro Hound-FR (2 m optical path)
PortabilityPortable
Response Time< 1 s
Detection PrincipleUltraviolet Differential Optical Absorption Spectroscopy (UV-DOAS)
Detection CapabilitySimultaneous real-time quantification of up to 15 gas species
Detection LimitSub-ppb level for key analytes (e.g., SO₂, NO₂, O₃, benzene, toluene, formaldehyde)
Integrated ComponentsRechargeable battery pack, high-resolution UV spectrometer (200–400 nm), 15 CFM sampling pump, sub-micron particulate filter
Regulatory AlignmentDesigned to support EPA Method TO-15 / TO-14A compliance workflows, compatible with ISO 12039 and ASTM D6348 validation frameworks
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAP2E
OriginImported (France)
ModelProCeas
PrincipleTunable Diode Laser Infrared Absorption Spectroscopy (TDLAS) with Optical Feedback Cavity-Enhanced Absorption Spectroscopy (OFCEAS)
ConfigurationOnline, Rack-Mountable (19", 4U)
Response Time<1 s
Detection LimitsSub-ppb to low-ppm (gas-dependent)
Measured GasesHCHO, H₂S, CH₄, CO, CO₂, H₂, H₂O, HCl, HCN, HF, N₂O, NH₃, O₂, NO, NO₂
SamplingLow-Pressure Sampling (LPS) System with Sonic Nozzle
Zero DriftNone (real-time cavity ring-down noise monitoring & auto-zero compensation)
CalibrationFactory pre-calibrated