- All
- Favorite
- Popular
- Most rated
| Brand | AP2E |
|---|---|
| Origin | Imported (France) |
| Model | ProCeas |
| Principle | Tunable Diode Laser Infrared Absorption Spectroscopy (TDLAS) with Optical Feedback Cavity-Enhanced Absorption Spectroscopy (OFCEAS) |
| Configuration | Online, Rack-Mountable (19", 4U) |
| Response Time | <1 s |
| Detection Limits | Sub-ppb to low-ppm (gas-dependent) |
| Measured Gases | HCHO, H₂S, CH₄, CO, CO₂, H₂, H₂O, HCl, HCN, HF, N₂O, NH₃, O₂, NO, NO₂ |
| Sampling | Low-Pressure Sampling (LPS) System with Sonic Nozzle |
| Zero Drift | None (real-time cavity ring-down noise monitoring & auto-zero compensation) |
| Calibration | Factory pre-calibrated |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS HCl Flue Gas Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Flow Accuracy | ±2% |
| Compliance | EN 1911, ISO 9096:1992 |
| Operating Probe Temperature | ≥120 °C (≥20 °C above HCl acid dew point) |
| Filter Efficiency | >99.5% (glass fiber or quartz fiber) |
| Sample Transit Time | <5 s (nozzle to impinger) |
| Main Stream Flow Rate | 30–150 L/min (isokinetic mode) |
| Impinger Flow Rate | 2–3 L/min |
| Typical Sampling Volume | 50–200 L (for [HCl] = 1–10 mg/m³ |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Mercury Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Target Analyte | Mercury (Hg) and Other Heavy Metals |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 13211 |
| Sample Path Material | Borosilicate Glass & Inert Heated Components |
| Probe Operating Temperature | ≥120 °C (≥20 °C above acid dew point) |
| Max. Sample Residence Time | <5 s (from probe inlet to impinger train) |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS Flue Gas Heavy Metal Sampler |
| Instrument Type | Particulate and Heavy Metal Sampling System |
| Target Analytes | Heavy Metals (e.g., Pb, Cd, Hg, As, Ni, Cr) |
| Flow Accuracy | ±2% |
| Compliance Standard | UNI-EN 14385 |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS Flue Gas Particulate Sampling System |
| Instrument Type | Isokinetic Particulate Sampler |
| Flow Accuracy | ±2% |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Dioxin |
| Instrument Type | Flue Gas Dioxin Sampling System |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 1948:2006 |
| Sampling Methods | Filter-Condensation, Dilution, Cooled Probe |
| Primary Adsorbent | XAD-2 Resin or PUF Foam |
| Heating Zone Temperature | <125 °C (maintained above gas dew point) |
| Condenser Outlet Temperature | <20 °C |
| Main Flow Rate | 3–5 m³/h |
| Side Stream Flow Rate | 0.5–0.7 m³/h |
| Side-to-Main Flow Ratio Tolerance | ±10% |
| Linear Velocity in XAD-2 Tube | ≤34 cm/s |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Propane |
| Instrument Type | Portable |
| Detection Range | Configurable from ppb to ppm |
| Resolution | <3 ppb/s |
| Response Time | 1 s |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA LDS |
| Instrument Type | Portable |
| Sensitivity | CH₄ < 1 ppb/s, C₂H₆ < 500 ppt/s |
| Measurement Principle | Mid-Infrared Laser Absorption Spectroscopy |
| Path Length | 13 m in 60 mL sample cell |
| Detection Targets | CH₄, C₂H₆, H₂O (dry mole fraction reported) |
| Ethane/Methane Ratio Accuracy | ±0.02% (e.g., 4.42% ± 0.02%) |
| Drift (Ultra) | ≤2 ppb or 0.1% of reading across full temperature range |
| Operating Environment | 10–40 °C, 10–95% RH (non-condensing) |
| Data Output Rate | 1–2 Hz standard, up to 10 Hz optional |
| GPS Accuracy | High-precision embedded GNSS with magnetic-mount antenna |
| Power Consumption | 15–25 W depending on configuration |
| Dimensions & Weight | Pico (2.75 kg), Ultra Portable (6.5 kg), Strato (2.0 kg) |
| Data Storage | 32 GB internal (expandable) |
| Communication Interfaces | Wi-Fi, RS-232, USB, analog output (optional) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA N2O CO₂ |
| Instrument Type | Portable |
| Target Gases | N₂O, CO₂, H₂O (simultaneous) |
| Repeatability | 1 ppb |
| Resolution | 200 ppt/s (N₂O), 200 ppb/s (CO₂) |
| Response Time | 1 s |
| Zero Drift | <1 ppb (N₂O), <1 ppm (CO₂) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 10–95% RH (non-condensing) |
| Measurement Range | N₂O: <2 ppb – 500 ppm |
| CO₂ | <10 ppm – 10% |
| Data Output Rate | 1–10 Hz |
| Power Consumption | 15–25 W (model-dependent) |
| Dimensions & Weight | Model-specific (Pico: 11.5" × 8" × 3.75", 2.75 kg |
| Ultra Portable | 15" × 12" × 7", 6.5 kg |
| Strato | 7.5" × 7.5" × 3.5", 2 kg) |
| Connectivity | Wi-Fi, USB, RS-232, Analog Output (optional) |
| Internal Storage | 32 GB (expandable) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA OCS |
| Price | Upon Request |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Model | MIRA N2O/CO |
| Instrument Type | Portable |
| Measured Gases | N₂O, CO |
| Response Time | 1 s |
| Measurement Accuracy | CO < 1 ppb, N₂O < 1 ppb (2 ppb without zeroing) |
| Measurement Range | 1 ppb – 500 ppm |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Acetylene |
| Instrument Type | Portable |
| Detection Range | Configurable from ppb to ppm |
| Resolution | <3 ppb/s |
| Response Time | 1 s |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA VOC |
| Pricing | Upon Request |
| Principle | Photoacoustic Spectroscopy (PAS) with Mid-Infrared Laser Absorption |
| Measurement Range | 1 ppb to 500 ppm |
| Resolution | 1 ppb |
| Repeatability | ±2% of reading |
| Sampling Method | Tunable Mid-IR Laser Absorption Spectroscopy |
| Response Time | <1 s (T90) |
| Operating Temperature | 10–40 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Model | MIRA Ultra |
| Detection Principle | Multi-pass Absorption Cell Coupled with Solid-State Mid-Infrared Laser Spectroscopy |
| Precision | CH₄: <1 ppb/s, N₂O: <200 ppt/s, CO₂: <200 ppb/s |
| Measurement Ranges | CH₄: 10 ppb – 10,000 ppm |
| N₂O | <2 ppb – 500 ppm |
| CO₂ | <10 ppm – 10% |
| H₂O | Full-range humidity compensation |
| Optical Path Length | 15 m in 60 mL cell volume |
| Data Output Rate | 1–10 Hz (configurable) |
| Dimensions | 45.7 × 38.1 × 17.8 cm (W×D×H) |
| Weight | 8.5 kg |
| Power Consumption | 25 W |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 10–95% RH (non-condensing) |
| Internal Battery Life | 6 hours |
| Communication Interfaces | Wi-Fi, USB, RS-232, Analog Output (optional) |
| Onboard Storage | 32 GB (expandable) |
| Brand | Aeris Technologies |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA Eto |
| Pricing | Upon Request |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | PSMPS |
| Measurement Principle | Scanning Electrical Mobility Spectrometry (SEMS) |
| Sample Flow Rate | 2.5 L/min |
| Size Range | 1.1–155 nm |
| Counting Range | 10⁷ particles/cm³ |
| Size Channels | 45–255 channels (step mode) |
| DMA Types | S-DMA (1.1–55 nm), M-DMA (2.8–155 nm) |
| PSM Working Fluid | Diethylene Glycol |
| PSM d₅₀ Tunable | 1.3–3.5 nm |
| CPC Working Fluid | Isopropanol |
| CPC d₅₀ | 4 nm |
| CPC Flow Options | 0.3 or 0.6 L/min (aerosol), 3 or 10 L/min (sheath) |
| Operating Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 600–1050 mbar |
| Power | 100–240 VAC, 50/60 Hz, max. 280 W (system) |
| Dimensions | DMA/PSM unit: 29 × 45 × 46.5 cm |
| CPC unit | 40 × 25 × 29 cm |
| Weight | DMA/PSM unit: 17 kg |
| CPC unit | 12.4 kg |
| Brand | ISAP |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISAP Arctic-Grade Aerosol Sampler |
| Pricing | Available Upon Request |
Show next