- All
- Favorite
- Popular
- Most rated
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Model | PAS2000 STD |
| Instrument Type | Aerosol Detector |
| Detection Principle | UV Photoionization of Particle-Bound Polycyclic Aromatic Hydrocarbons (PAHs) |
| Measurement Range | 0–100 µg/m³ (PAH), 0–100 µg/m³ (Elemental Carbon), 0–100 pA (Ion Current) |
| Detection Limit | 3 ng total adsorbed PAH |
| Sensitivity | 0.3–1 µg/m³ PAH per pA |
| Response Time | <10 s (adjustable) |
| Flow Rate | 2 LPM |
| Operating Temperature | 5–40 °C |
| Data Storage | 8,000 points (timestamped) |
| Display | 2×16-character LED |
| Output Interfaces | RS-232, 0–10 V, 0–20 mA, or 4–20 mA |
| Dimensions | 68 × 175 × 124 mm |
| Weight | 9 kg |
| Power Supply | 220 V AC / 50 Hz |
| Optional Heated Sampling Probe | 5–300 °C |
| Dilution Ratios | 0.05, 0.1, 0.2 (with mass flow controller and critical orifice) |
| Brand | Plair |
|---|---|
| Origin | Switzerland |
| Model | Rapid-E+ |
| Instrument Type | Bioaerosol Detector |
| Particle Size Range | 0.3–100 µm |
| UV Laser Wavelength | 337 nm |
| Scatter Laser Wavelength | 445 nm |
| Imaging Laser Wavelength | 635 nm |
| Scatter Pixel Configuration | 14+14 (non-polarized + parallel-polarized) |
| Fluorescence Spectral Range | 350–540 nm (12 nm/pixel) |
| Fluorescence Lifetime Channels | 373–387 nm, 412–438 nm, 459–481 nm |
| Fluorescence Decay Resolution | 1 ns |
| Imaging Pixel Configuration | 16 (5 parallel-polarized, 5 perpendicular-polarized, 6 non-polarized) |
| Sampling Flow Rate | 5 L/min |
| Max. Counting Rate | 1,000,000 particles/min (size & count) |
| Power Supply | 90–240 VAC |
| Power Consumption | <200 W |
| Dimensions | 40 × 34 × 73 cm |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Weight | 25 kg |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC-2200CE |
| Instrument Type | Aerosol Detector |
| Power Supply | 15 V Rechargeable Li-ion Battery |
| Display | 2-line × 16-character LED |
| Weight | 1.5 kg |
| Dimensions | 68 mm × 175 mm × 124 mm |
| Operating Temperature | 5–40 °C |
| Storage Capacity | 8,000 data points (timestamp + surface area value) |
| Flow Rate | 1 LPM |
| Measurement Range | 0–1000 µm²/cm³ |
| Detection Limit | 0–10 µm²/cm³ |
| Sensitivity | 0–10 µm²/cm³ |
| Response Time | <10 s (adjustable) |
| Data Output | RS232 |
| Software Compatibility | PC-based charting utility with Excel export |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | DMA |
| Instrument Type | Aerosol Detector |
| Particle Size Range (L-DMA) | 5–350 nm (3.0 L/min sheath flow) / 10–1100 nm (20 L/min sheath flow) |
| Sheath Gas Flow | 3.0 L/min (standard), up to 150 L/min (high-flow variant) |
| Sample Flow | 0.3 L/min |
| High-Voltage Output | +5 to +10,000 V (positive inner electrode), negative polarity optional |
| Resolution | Up to 256 size channels |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 85–264 VAC |
| Communication | RS-232 (9-pin D-sub), ASCII protocol, 4 MB PCMCIA SRAM |
| Working Fluid | Reagent-grade 1-Butanol |
| Safety | Automatic HV shutdown upon housing opening |
| Compliance | Designed for ISO 27498, ASTM D6243, and EU PM2.5/PM10 monitoring frameworks |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | ESS |
| Instrument Type | Aerosol Sampling and Dilution System |
| Sample Gas Max Temperature | 500 °C |
| Probe Outer Diameter | 8 mm |
| Hot Dilution Air Flow Rate | 9 L/min (per stage) |
| Cold Dilution Air Flow Rate | 9 L/min |
| Primary Dilution Ratio (SMPS+E mode, 1 L/min sample flow) | 1:10 |
| Secondary Dilution Ratio (SMPS+E mode, 1 L/min sample flow) | 1:10 |
| Total Dilution Ratio (SMPS+E mode, 1 L/min sample flow) | 1:100 |
| Primary Dilution Ratio (SMPS+E mode, 0.3 L/min sample flow) | 1:31 |
| Secondary Dilution Ratio (SMPS+E mode, 0.3 L/min sample flow) | 1:31 |
| Total Dilution Ratio (SMPS+E mode, 0.3 L/min sample flow) | 1:961 |
| Heater Max Temperature | 200 °C |
| Pressure Tolerance | ±100 mbar (vs. ambient) |
| Dilution Air Specification | Particle-free, hydrocarbon-free, dry |
| Brand | EDC |
|---|---|
| Origin | USA |
| Model | DPM-4000 |
| Instrument Type | Aerosol Detector |
| Measurement Range | 1–20,000 µg/m³ |
| Resolution | ±2 µg/m³ |
| Accuracy | ±10% |
| Particle Size Range | <1–10 µm |
| Sampling Flow Rate | 1.0–3.3 L/min (recommended 1.7 L/min) |
| Display | 4-line × 20-character LCD (units: µg/m³, mg/m³, TWA, STEL, min/max) |
| Data Storage | 21,500 points (>5 years retention) |
| Logging Interval | 1 sec to 21 weeks |
| Alarm | 90 dB at 3 ft |
| Operating Temp | 0–50 °C |
| Storage Temp | −20–70 °C |
| Humidity | ≤95% RH non-condensing |
| Power | Rechargeable battery (>8 h runtime |
| Dimensions | 140 × 83 × 70 mm |
| Weight | 1.0 kg |
| Compliance | NIOSH 5040 compatible, NIST-traceable calibration support, OSHA-compliant exposure assessment |
| Brand | Oxility |
|---|---|
| Origin | Netherlands |
| Model | Nano Tracer XP |
| Instrument Type | Aerosol Detector |
| Measurement Range | 10–300 nm |
| Output Parameters | Total Particle Number Concentration, Mean Particle Diameter, Lung Deposited Surface Area (LDSA) |
| Detection Principle | Diffusion Charging + Electrometer-based Quantification (Aerasense Technology) |
| Noise Level | <35 dB(A) |
| Pump Lifetime | 40,000 hours |
| Compliance | Validated per IGF (Institut für Gefahrstoffe) independent testing protocol |
| Software | NanoReporter (real-time multi-unit dashboard, audit-ready data export, report generation) |
| Brand | Hund |
|---|---|
| Origin | Germany |
| Model | BAA500e |
| Instrument Type | Aerosol Detector |
| Pollen Identification Capacity | 40+ species (expandable) |
| Accuracy | >90% |
| Sensitivity | 1 particle/m³ |
| Particle Size Range | 10–150 µm |
| Sampling Flow Rate | 1117 L/min |
| Dimensions | 900 mm × 700 mm × 1800 mm |
| Weight | ≤400 kg |
| Power Supply | 230 V AC / max. 3.7 kW |
| Operating Temperature | −20 °C to +40 °C |
| Relative Humidity | 0–100% RH |
| Sampling Interval | 1–3 h |
| Autonomous Operation Duration | 2–4 weeks |
| Sample Carrier Capacity | Reusable magazine-style cassette (8–24 carriers/day) |
| Brand | GRIMM |
|---|---|
| Origin | Germany |
| Model | UF-CPC |
| Instrument Type | Aerosol Detector |
| Particle Size Range | 5 nm – 10,000 nm |
| Concentration Range (UF-CPC 100) | ≤ 20,000 P/cm³ (single-particle counting), < 10⁷ P/cm³ (photometric mode) |
| Concentration Range (UF-CPC 200) | ≤ 1,000,000 P/cm³ (single-particle counting), < 10⁷ P/cm³ (photometric mode) |
| Concentration Accuracy | ±5% (single counting), ±10% (photometric mode) |
| Response Time (t₉₀) | 3 s |
| Working Fluids | Butanol, Isopropanol, or Water |
| Aerosol Flow Rate | 0.30–0.60 L/min |
| Signal Processing | 20 MHz detection rate, 256 raw data channels |
| Embedded OS | Intel Atom™ 1.6 GHz processor, 2 GB CompactFlash, 800 × 480 touchscreen display |
| Connectivity | USB, Ethernet, RS232/RS485 |
| Power Supply | 115/230 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 33 × 38 × 24 cm |
| Weight | 10 kg |
| Brand | GRIMM |
|---|---|
| Country of Origin | Germany |
| Model | FCE |
| Instrument Type | Aerosol Detector |
| Voltage Range | 0–10,000 V (user-selectable polarity) |
| Flow Rate | 0.3–5 L/min (external pump required) |
| Electrode Diameter | 10 mm or 20 mm (magnetically mounted) |
| Substrate Compatibility | Conductive or non-conductive sampling substrates |
| Particle Size Range | 0.8–1100 nm (when coupled with GRIMM DMA systems) |
| Dimensions | Ø126 mm × H264 mm |
| Weight | 3.3 kg |
| Power Supply | 100–240 VAC, 50–60 Hz or 12–18 VDC |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Status Indication | LED indicators |
| Brand | Yamatronics |
|---|---|
| Origin | Japan |
| Model | KH-3000-01A |
| Instrument Type | Aerosol Particle Counter for Pollen Detection |
| Measurement Principle | Forward + Sideways Semiconductor Laser Light Scattering |
| Particle Size Range | ~25–40 µm |
| Flow Rate | 4.1 LPM |
| Measurement Interval | 1–9999 min (adjustable) |
| Display | LCD |
| Interface | RS-232C |
| Data Storage Capacity | 180 records |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions | 320(W) × 230(D) × 140(H) mm |
| Weight | ~5 kg |
| Compliance | Designed for ambient airborne pollen surveillance in accordance with ISO 21501-4 and JIS Z 8901 Annex B for optical particle counting |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Model | PAS-2200CE |
| Instrument Type | Aerosol-Bound PAH Monitor |
| Detection Principle | UV Photoionization of Adsorbed PAHs |
| Measurement Range | 0–1000 ng/m³ |
| LOD | 10 ng/m³ (total adsorbed PAH) |
| Flow Rate | 1 L/min |
| Response Time | <10 s (adjustable) |
| Sensitivity | 10 ng/m³ |
| Operating Temperature | 5–40 °C |
| Data Storage | 8,000 points (timestamped) |
| Weight | 1.5 kg |
| Dimensions | 58 × 175 × 124 mm |
| Power | 15 V DC (rechargeable battery) or 220 V AC/50 Hz |
| Display | 2-line × 16-character LED |
| Output | RS232 serial interface |
| Data Logging | Embedded system (up to 2,500 records) |
| Brand | EDC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PC-2HX |
| Instrument Type | Aerosol Size Distribution and Mass Concentration Analyzer |
| Measurement Principle | Inertial Impaction with QCM Gravimetric Detection |
| Size Range | 0.1–25 µm (10-stage cascade impactor configuration) |
| Flow Rate | 2.0 L/min (PC-2HX variant) |
| Mass Sensitivity | 1 ng/Hz |
| Detection Limit | ~5 µg/m³ (typical) |
| Minimum Detectable Particle Diameter | 100 nm |
| Output | Real-time size-resolved mass concentration (µg/m³ per stage), PM₁ / PM₂.₅ / PM₁₀ equivalent calculation, timestamped histogram export |
| Interface | RS-232 / USB to PC |
| Sample Substrate | Removable QCM crystals or aluminum collection plates for SEM/EDS analysis |
Show next