- All
- Favorite
- Popular
- Most rated
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR5000 |
| Instrument Type | Flue Gas CEMS |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Stability | <2% FS |
| Response Time | Real-time |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC, CH₄, H₂S, HCl, NH₃, N₂O, O₃, PM |
| Sensor Technologies | Electrochemical (O₂, NO, NO₂, CO, SO₂, H₂S, NH₃, HCl, N₂O, O₃), NDIR (CH₄, CO₂*), Catalytic Bead (HC), Optional Paramagnetic (O₂), Thermal Conductivity (H₂), Optical Scattering (PM) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | 2800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% FS |
| Response Time | <90 s |
| Drift Stability | <5% over 1 h |
| Measured Parameters | O₂, NO, NO₂, CO, SO₂, HC/CH₄, Flue Gas Temperature (TG), Ambient Temperature (TA) |
| Sensor Technology | Electrochemical (O₂, NO, NO₂, CO, SO₂, HC/CH₄) |
| Operating Temperature Range (Probe) | Up to 1200 °C (1600 °C optional) |
| Battery Life | 6 h (rechargeable Li-ion) |
| Compliance | Certified for official emission monitoring per German TA Luft and EU Directive 2010/75/EU (IED), supports ASTM D6522, EN 15267-3, and VDI 3862 |
| Data Output | RS232, USB |
| Display | Backlit LCD showing up to 8 parameters simultaneously |
| Built-in Printer | Yes (programmable, on-site thermal printout) |
| Fuel Database | 23 preloaded fuel types + 4 user-definable |
| Calculated Parameters | λ (excess air ratio), qA (dry flue gas loss), CO₂ (by ASME PTC 4.1 equation), NOₓ (as NO₂-equivalent) |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | ProtIR 204M |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Accuracy (Relative Error) | <5% |
| Repeatability | <2% |
| Response Time | <30 s |
| Long-term Stability | <5% over 7 days |
| Measured Gases | SO₂, NO, NO₂, CO, CO₂, HCl, HF, NH₃, CH₄, N₂O, H₂O vapor, and >28 pre-calibrated VOCs & inorganic species |
| Spectral Resolution | 1–128 cm⁻¹ (selectable) |
| Wavenumber Range | 485–8500 cm⁻¹ |
| Optical Path Length | 6.4 m |
| Detector | DTGS |
| IR Source | Globar mid-IR source |
| Beamsplitter | ZnSe |
| Sample Cell Material | Nickel-plated aluminum with gold-coated mirrors & BaF₂ windows |
| Operating Temperature | 5–40 °C |
| Weight | 71 kg |
| Dimensions | 117 × 66.5 × 43 cm |
| Data Interface | Ethernet (OPC DA v3.0 compliant), 16 × 4–20 mA outputs (optional), 5 × digital I/O (optional) |
| Software Suite | PAS, PAS-Pro, Protea Spectrum Viewer |
| Calibration Support | Automated N₂ purge, real-time pressure & temperature compensation, built-in zirconia O₂ sensor (optional), dynamic dilution module (optional) |
| Compliance | UK MCerts certified, compatible with BS EN 14181, EN 15267, ISO 12039, and EPA Method 320 |
| Brand | Pentol |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PENTOL |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Turbidimetric Spectrophotometry |
| Measurement Range | 1–200 ppm SO₃ |
| Accuracy | ±5% of reading (calibrated range) |
| Repeatability | ±2% |
| Response Time (90% FSD) | <120 s |
| Drift Stability | ±5% over 30 days |
| T90 Delay | ~60 s |
| Sample Flow Control | Precise dual-pump liquid/gas flow regulation |
| Absorbent | Aqueous isopropanol solution |
| Reaction Chemistry | SO₃ → H₂SO₄ → SO₄²⁻ → BaClO₄⁻ complex formation |
| Reagent Consumption | 0.25–2 cm³/h (adjustable) |
| Operating Ambient Temperature | 0–40 °C |
| Power Supply | 230 V / 110 V, 50/60 Hz, 350 W |
| Analyzer Module | 19″ rack, 6U height, 500 mm depth, 27 kg |
| Control Module | 19″ rack, 4U height, 500 mm depth, 13 kg |
| Probe Length Options | 1.0, 1.2, 1.5, 2.0 m |
| Analog Output | 4–20 mA (isolated) |
| Digital Interface | RS232 (optional, factory-configurable) |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMREX660 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time (T90) | <30 s |
| Stability | <2% FS over 8 h |
| Operating Temperature | –20°C to +50°C (toxic gases) |
| Operating Humidity | <95% RH, non-condensing |
| Weight | 500 g |
| Dimensions | 168 × 91 × 45 mm |
| Data Storage Capacity | 100,000 records |
| Battery Life | Up to 30 h (rechargeable Li-ion) |
| Detection Methods | Electrochemical, Catalytic Bead, NDIR, PID, and Semiconductor Sensors |
| Gas Channels | Up to 6 simultaneous sensor modules (7 gas parameters concurrently) |
| Alarm Modes | Dual-stage audible (buzzer), visual (LED flash), and tactile (vibration) |
| Compliance | Certified per German TA-Luft emission guidelines |
| Brand | IMR |
|---|---|
| Origin | USA |
| Model | IMR1400C |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <2% FS |
| Repeatability | <2% FS |
| Response Time | 1 s |
| Stability | <2% FS over 8 h |
| Measurable Gases | O₂, NO, NO₂, CO, SO₂, HC/CH₄ |
| Optional Sensors | HCl, N₂O, Cl₂, H₂, NH₃, H₂S, CO₂ (IR) |
| Operating Temperature Range | –20 °C to +1200 °C (flue gas), –20 °C to +120 °C (ambient) |
| Dimensions | 305 × 228.6 × 117 mm |
| Weight | 2.9 kg |
| Battery Life | Up to 6 h (rechargeable Li-ion) |
| Communication Interfaces | RS232, USB |
| Compliance | Certified for official emissions monitoring per German TA-Luft and EU EN 15267-3 |
| Brand | Pentol |
|---|---|
| Origin | Germany |
| Model | SO3 Generator |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Component |
| Measurement Accuracy | ±5% |
| Repeatability | ±5% |
| Response Time | 1 s |
| Long-Term Stability | ±5% |
| Target Analyte | SO₃ |
| Catalyst | V₂O₅ |
| SO₂ Feed Rate | 2–200 L/h |
| Air Dilution Flow | 100–5,000 L/h |
| Max Operating Temperature | 1000 °C |
| Heating Rate (to 500 °C, no load) | 20 K/min |
| Power Supply | 400 V / 30 A / 7 kW |
| Dimensions (L×W×H) | 1800 × 1400 × 1200 mm |
| Weight | 429 kg |
Show next