Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
ModelEDM365
Measurement PrincipleOptical (90° Laser Scattering)
Sampling Flow Rate1.2 L/min
Particle Size Range0.25–32 µm
Number Concentration Range1–3,000,000 particles/L
Size Channels31
Mass Concentration Range0.1–6,000 µg/m³
Operating Temperature−25 °C to +50 °C
Power Supply230 V–50 Hz / 110 V–60 Hz
Dimensions80 × 60 × 40 cm
Weight25 kg
Repeatability±3% of full scale
ComplianceEN 12341, EN 14907, US-EPA Reference/Equivalent Method Designation, GOST R
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
ModelSMPS+E
PrincipleScanning Mobility Particle Sizing (SMPS)
Sample Flow Rate1–5 L/min
Particle Size Range0.8 nm – 1100 nm
Number Concentration Range1–3,000,000 particles/L
Size Channels255
Particle Mass Concentration Rangeup to ~10⁸ particles/cm³
Sheath Flow Rate3–20 L/min
Maximum Scan Frequency16 Hz
FCE Response Time (T₉₀)200 ms
FCE Sensitivity0.1 fA at 1 Hz
FCE Noise Level0.35 fA (τ = 0.25 s, 90% confidence)
DMA Voltage Range5–10,000 V
Operating Pressure Range400–1100 mbar
Power Supply230 VAC / 120 VAC, 50–60 Hz or 12 VDC ±10%
ComplianceISO 15900:2020 (Determination of particle size distribution by electrical mobility analysis)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
Model11-D
Measurement PrincipleSingle-Particle 90° Laser Light Scattering
Sampling Flow Rate1.2 L/min ± 3%
Particle Size Range0.253–35.15 µm
Number Concentration Range1–3,000,000 particles/L
Size Channels31 equidistant logarithmic channels
Mass Concentration Range0.1 µg/m³ – 100 mg/m³
Battery Life10 h (Li-ion, 10.8 V / 6.5 Ah)
Dimensions27 × 13 × 7 cm
Weight2.1 kg
Operating Temperature+4 °C to +40 °C
Relative Humidity<95% RH (non-condensing)
ComplianceISO 21501-1, EN 481
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
Model1371
Sampling Flow Rate1.2 L/min ±5%
Particle Size Range10 nm – 35 µm
Number Concentration Range1 – 3,000,000 particles/L
Number of Size Channels41
Mass Concentration Range0.0001 – 100 mg/m³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
ModelSMPS+C
PrincipleScanning Mobility Particle Sizing
Sample Flow Rate0.3 L/min
Particle Size Range5 nm – 1100 nm
Counting Range1 – 3,000,000 particles/L
Size ChannelsStandard 44, up to 255 logarithmically spaced channels
Particle Number Concentration Range1 – 10⁷ particles/cm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
ModelEMD264
Measurement PrincipleOptical Light Scattering (90° Single-Particle Detection)
Sampling Flow Rate1.2 L/min ±3% (constant-flow, ISO 21501-1 compliant)
Particle Size Range0.253–35.15 µm
Number Concentration Range0–5,300,000 particles/L
Size Channels31 equidistant logarithmic channels
Mass Concentration Range0–100 mg/m³
Time Resolution6 s (standard), configurable to 1.5/10/15/30/60 min
Operating Temperature−20 °C to +40 °C
Relative Humidity<99% RH (non-condensing)
Pressure Range553–1133 mbar (altitude ≤5000 m)
Power Supply100–240 VAC, 50/60 Hz or 12 VDC
Dimensions (housing)44 × 45 × 21 cm
(with probe & sensors)73 × 51 × 23 cm
Weight10 kg (housing only)
Self-Cleaning Air Flow0.4 L/min
GPS Accuracy>97% repeatability (ISO 21501-1)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
ModelEDM665
PrincipleCombined Scanning Mobility Particle Sizer + Optical Particle Counter (SMPS+C + OPC)
Sample Flow Rate1.2 L/min (OPC), 0.3 L/min (SMPS)
Particle Size Range5.5 nm – 32 µm
Counting Concentration Range1 – 10⁷ particles/cm³
Size Channels71 total (44 SMPS + 31 OPC)
Repeatability±3%
Operating Temperature−20 °C to +55 °C
Power Supply110/220 VAC, 50/60 Hz, 750 W
Dimensions60 × 60 × 120 cm
Weight120 kg (incl. power unit)
Sampling Inlet1.5 m standard (3 m optional), with isothermal dehumidification system
EnclosureWeatherproof outdoor cabinet with active air conditioning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
ModelPSMPS
Measurement PrincipleScanning Electrical Mobility Spectrometry (SEMS)
Sample Flow Rate2.5 L/min
Size Range1.1–155 nm
Counting Range10⁷ particles/cm³
Size Channels45–255 channels (step mode)
DMA TypesS-DMA (1.1–55 nm), M-DMA (2.8–155 nm)
PSM Working FluidDiethylene Glycol
PSM d₅₀ Tunable1.3–3.5 nm
CPC Working FluidIsopropanol
CPC d₅₀4 nm
CPC Flow Options0.3 or 0.6 L/min (aerosol), 3 or 10 L/min (sheath)
Operating Humidity0–95% RH (non-condensing)
Pressure Range600–1050 mbar
Power100–240 VAC, 50/60 Hz, max. 280 W (system)
DimensionsDMA/PSM unit: 29 × 45 × 46.5 cm
CPC unit40 × 25 × 29 cm
WeightDMA/PSM unit: 17 kg
CPC unit12.4 kg