BrandAQUALABO
OriginFrance
ModelUVILINE 8100C / 9100C / 9400C
Wavelength Range320–1100 nm (8100C/9100C), 190–1100 nm (9400C)
Light SourceTungsten-Halogen (8100C/9100C), Xenon Flash Lamp (9400C)
Spectral Bandwidth6 nm (8100C), 4 nm (9100C/9400C)
Wavelength Accuracy±2 nm (8100C), ±1 nm (9100C/9400C)
Wavelength Repeatability±0.5 nm
Absorbance Range±3300 Abs
Absorbance Resolution0.001 Abs or 0.1% T
Photometric Accuracy±0.005–0.016 Abs (dependent on range)
Stray Light<0.1% at 340 nm (NaNO₂), <1% at 220–400 nm (GG375/GG408/NaI)
Baseline Stability±0.01 Abs
Scan SpeedLow/Medium/Fast
Interface1× USB-A, 1× USB-B
Power Supply110–220 V, 50/60 Hz
Operating Temperature10–35 °C
Dimensions (L×W×H)404 × 314 × 197 mm
Weight4.7 kg (8100C), 4.0 kg (9100C/9400C)
IP RatingIP30
SoftwareSpectralab v5.x (GLP-compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelS200
Instrument TypeOnline Analyzer
Measurement PrinciplePotentiometric (Gold Ring Electrode)
Ozone Range0–1 mg/L or 0–5 mg/L
pH Range−2 to 16
Temperature Range−30.00 to 140.00 °C
Accuracy±2 % of full scale
ResolutionOzone 0.001/0.01 mg/L
Response Time30 s
Max. Operating Pressure8 bar @ 20 °C
Max. Water Temperature70 °C
Flow Rate40–120 L/h
Sensor MaterialGlass body with gold ring electrode
Enclosure RatingIP65
Power Supply230 VAC ±10 % or 110 VAC ±10 %, 50/60 Hz
Power Consumption16 VA
Dimensions (W×H×D)160 × 165 × 85 mm
Weight1.1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelODEON
Instrument TypePortable/Handheld Water Quality Analyzer
Detection ParametersNtotal, Cl⁻, ClO₂, F⁻, Fe, CN⁻, BZT (Benzotriazole), SiO₂, Cr⁶⁺, Cr, MoO₄²⁻ (Mo), pH, Al³⁺, Br₂, Cu, Ni, Zn, P₂O₅, H₂O₂, N₂H₄ (Hydrazine), Mg²⁺, Mn²⁺, Cu²⁺, Ni²⁺, Ca²⁺, O₃, S²⁻, PO₄³⁻-P, TP (Total Phosphorus), K⁺, Al, Free Chlorine, Total Chlorine, Cyanuric Acid, Hydrazine, Hardness & Total Alkalinity, Turbidity, Benzotriazole, Phenol
Photometer Wavelengths400 nm, 468 nm, 518 nm, 591 nm, 639 nm
DetectorSilicon Photodiode
Cuvette TypeRound, 16 mm diameter
Data Storage CapacityUp to 100,000 readings
Display4-inch high-resolution LCD
Protection RatingIP67
Battery LifeUp to 2000 hours
ComplianceGLP-compliant data logging with audit trail, auto-calibration diagnostics, automatic temperature compensation
ConnectivityRS-485 digital interface
Electrode CompatibilitySingle-parameter and 3-in-1 multiplexed sensors (pH/ORP/DO/Conductivity/Turbidity)
AccessoriesY-adapter cables, digestion units, pre-filled reagent tubes (liquid/tablet/tube formats), portable carrying case
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelSTAC CL
Instrument TypeOnline Analyzer
Measurement PrincipleUV Absorption Spectrophotometry (204–321 nm)
Measured ParametersFree Chlorine (Cl₂), Total Chlorine, Chlorine Dioxide (ClO₂), Hydrogen Sulfide (H₂S)
RangeCl₂ 4–3000 mg/L
Optical Path Length Options2 mm (Cl₂: 100–3000 ppm, H₂S LOD: 10 ppm), 5 mm (Cl₂: 40–1200 ppm, H₂S LOD: 4 ppm)
SpectrometerUV Multichannel Spectrophotometer
Sample FlowGravity-fed, max. pressure 1 bar
Channels1 standard, up to 4 programmable sample channels + blank channel
Valves2–5 solenoid valves
Detection MethodDeconvolution-based spectral analysis using reference spectra libraries
Data OutputFour 4–20 mA analog outputs + RS232C interface
Operating Temperature15–40 °C
Sample Temp.≤40 °C
Sample MatrixNatural or treated water, suspended solids <2 mm
Power Supply230 V AC, 50/60 Hz, 300 VA
Dimensions800 × 600 × 360 mm
Weight15 kg
Light SourceDeuterium lamp (rated for ≥100,000 measurements)
Memory Capacity4 spectral models + 255 measurement records
SoftwareUV PRO for model calibration, spectrum visualization, maintenance diagnostics
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPONSEL
Price RangeUSD 140–7,200 (FOB)
Detection PrincipleConductive Liquid-Level Sensing
Output TypeNon-polarized Dry Contact (SPST)
Detection Threshold0.5 mm water film
Detector Housing MaterialPVC with Stainless Steel Electrodes
Electronics Enclosure MaterialPVC
IP RatingIP68 (Detector & Electronics Box)
Operating Temperature0–50 °C
Detector Dimensions (H×W×D)20 × 80 × 60.5 mm
Electronics Box Dimensions (H×D)120 × 40 mm
Detector-to-Box Cable Length9 m (fixed, shielded multi-strand polyurethane-sheathed cable)
Output CablesTwo 1 m polyurethane-sheathed leads with bare tinned-copper terminations
Power SupplyInternal Li-MnO₂ battery (3.6 V, 3-year typical service life) or external +3.6 V ±5% (SPN mode, <200 µA quiescent current)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelOPTOD
Instrument TypePortable & Online
Measurement PrincipleFluorescence Quenching
Range0.00–20.00 mg/L (ppm) / 0–200% saturation
Accuracy±0.1 mg/L
Resolution0.01 mg/L
Response Time (t₉₀)<60 s
Temperature CompensationIntegrated NTC thermistor
Operating Temperature–10°C to +60°C
Storage Temperature–10°C to +60°C
Pressure RatingUp to 5 bar
InterfaceModbus RTU over RS-485 (standard), SDI-12 (optional)
Power Supply5–12 V DC
Current Consumption25 µA (standby), 4.4 mA (RS-485, 1 Hz), 7.3 mA (SDI-12, 1 Hz), 100 mA (pulse)
DimensionsØ25 mm × 146 mm (sensor + 3 m cable)
Weight450 g
Housing MaterialPassivated 316L stainless steel or Grade 2 titanium
Protection RatingIP68
CertificationsASTM D888-05 compliant
Data LoggingOnboard non-volatile memory for calibration history and measurement records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelS200
Instrument TypeOnline Analyzer
Measurement PrinciplePotentiometric (Gold Ring Electrode)
Measured ParameterChlorine Dioxide (ClO₂)
RangeClO₂: 0.00–5.00 mg/L
pH–2.00 to 16.00
Temperature–30.00 to 140.00 °C
Accuracy±2 % of full scale
ResolutionClO₂: 0.01 mg/L
pH0.01 unit
Temperature0.1 °C
Response Time≤30 s
Max. Operating Pressure8 bar @ 20 °C
Max. Fluid Temperature70 °C
Flow Rate40–120 L/h
Sensor MaterialGlass body with gold-ring working electrode
Enclosure RatingIP65
Power Supply110/230 VAC, ±10 %, 50/60 Hz
Power Consumption16 VA
Dimensions (Analyzer)160 × 165 × 85 mm
Weight1.1 kg
Display4×20-character backlit LCD
Analog Outputs2 × isolated 4–20 mA (max. 600 Ω load)
Digital Inputs2 (including pulse input for flow meter)
Relay Outputs3 configurable (NO/NC/C, 120–240 VAC, 2 A)
Digital Outputs2 programmable dry-contact outputs (≤12 V, 200 mA)
Control FunctionsDual independent on/off, P or PI control, pulse-pause, frequency, and continuous analog output modes
Operating Temp.–20 to 55 °C (≤90 % RH at 40 °C, non-condensing)
Storage Temp.–20 to 65 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelC4E
Conductivity Range0–200.0 mS/cm
Resolution0.01–1 (scale-dependent)
Accuracy±1% of full scale
Salinity Range5–60 g/kg
TDS (KCl)0–133,000 ppm
Response Time<5 s
Operating Temperature0–50 °C
Temperature CompensationNTC
Output InterfaceModbus RS-485 (SDI-12 optional)
Update Interval<1 s
Supply Voltage5–12 V DC
Standby Current25 µA
Measurement Current (RS-485)6.3 mA @ 1 Hz
Pulse Current500 mA
DimensionsØ27 mm × 219 mm (total length)
Weight300 g (sensor + 3 m cable)
Housing MaterialsPVC, Delrin®, stainless steel
Max Pressure Rating5 bar
Protection RatingIP68
Connector9-pin armored connector with polyurethane jacket or waterproof Fisher-type
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelS200 TUr
Instrument TypeOnline
Turbidity Range0–10 NTU and 0–100 NTU
Measurement PrincipleNephelometric (90° scattered light, ISO 7027 compliant)
Resolution0.0001 NTU (0–10 NTU range)
Accuracy±2% of reading or ±0.02 NTU (0–40 NTU)
Response Time5–500 s
Sample Temperature Range1–50 °C
Operating Pressure Range104–1380 kPa (15–200 psi, factory-set default 15 psi)
Flow Rate100 mL/min–1 L/min
Analog Output4–20 mA (galvanically isolated, max. load 600 Ω)
Digital InterfaceRS485 Modbus RTU
Relay Outputs2 configurable (NO/NC/C, 120–240 VAC, 2 A)
Power Supply100–240 VAC, 47–63 Hz, 80 VA
Display4×20-character backlit alphanumeric LCD
Enclosure RatingIP66
Weight2.5 kg
Environmental LimitsIndoor use only
ComplianceISO 7027, CE, ETL Listed to UL 61010-1, CSA C22.2 No. 1010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
Model575 MP1
Instrument TypePortable
Temperature Range–5 to +50 °C (optional: –5 to +70 °C)
pH Range0–14
Conductivity Range0–200,000 µS/cm
Water Level Range0–100 m
Accuracy (Level)<0.05% FS
Accuracy (Temp)<0.1 °C
Accuracy (Conductivity)<0.5% of reading, min. 2 µS/cm
Accuracy (pH)<0.02
Resolution (Level)1 cm (standard), 1 mm (optional)
Resolution (Temp)0.1 °C (standard), 0.01 °C (optional)
Resolution (Conductivity)0.0005% FS
Resolution (pH)0.01
Long-term Stability (Level)<0.05%/year
Long-term Stability (Temp)<0.02 °C/year
Cable Lengthup to 500 m
Probe Depth Rating100 m
Housing Material316 stainless steel & titanium alloy
IP RatingIP68
PowerInternal rechargeable Li-ion battery (rated for ~3 million measurements at 2-min interval ≈ 10 years)
Memory4 MB flash storage
InterfacesRS-232, USB
Pressure CompensationIntegrated barometric compensation tube
Cable6 mm flexible UV-resistant PUR jacket with Kevlar reinforcement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelTRIPOD
Instrument TypePortable/Handheld Water Quality Analyzer
Measured ParameterspH, ORP, Temperature, Dissolved Oxygen (Optical), Turbidity (NTU/FNU/mg/L), Conductivity, Salinity, TDS
Communication ProtocolsModbus RS-485, SDI-12
Sensor ArchitectureIntegrated preamplification
Enclosure MaterialEPDM, PVC, Stainless Steel
Pressure Rating5 bar
IP RatingIP68
Dimensions (L × Ø)394 mm (incl. hook) × 75 mm
Weight1300 g
ComplianceASTM D888–05 (DO), ISO 7027 (Turbidity), C4E 4-electrode conductivity technology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelAPW
Measurement Principle950 nm Infrared Absorption
Wavelength950 nm (primary), 880 nm (for VB calibration)
Output Range0–100% VB (sludge interface visibility index)
Solids Concentration RangesVB5: 0–100 g/L, VB20: 0–7 g/L
Accuracy±2% of reading
Temperature CompensationAutomatic, Pt100 sensor integrated
Operating Temperature–10.0 to +60.0 °C
Sensor DimensionsØ43 mm (bottom), Ø25 mm (top), H210 mm
Sensor Weight400 g
Cable4-conductor shielded PU cable, standard 10 m (up to 100 m optional), 40 g/m
Sensor Housing MaterialDelrin®, polyurethane, and specialized optical glass
Sensor IP RatingIP68
Controller Power1 × 9 V alkaline battery (~2000 h typical life)
Controller EnclosureReinforced polyethylene with transparent IP67-rated cover
Controller Dimensions161 × 81 × 55 mm
Display3-digit LCD, 18 × 46 mm active area
Controller IP RatingIP65 (with IP67 cover installed)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelPHEHT
Measurement PrincipleComposite Glass Electrode (pH) / Platinum Redox Electrode (ORP) with Ag/AgCl Reference
pH Range0–14
pH Resolution0.01
pH Accuracy±0.1
ORP Range−1000 to +1000 mV
ORP Resolution0.1 mV
ORP Accuracy±2 mV
Temperature Range0.00–50.00 °C
Temp Resolution0.01 °C
Temp Accuracy±0.5 °C
Response Time<5 s
Output InterfaceModbus RTU over RS-485 / SDI-12 (selectable)
Power Supply5–12 V DC
Standby Current25 µA
Active Current (RS-485, 1 Hz)3.9 mA
Active Current (SDI-12, 1 Hz)6.8 mA
Peak Pulse Current500 mA
Housing MaterialPVC, Delrin®, specialty pH glass, platinum, polyamide
CableArmored coaxial polyurethane cable (3 m standard), optional Fisher connector
Pressure Rating5 bar
IP RatingIP68
DimensionsØ27 mm (body) / Ø21 mm (tip), L = 207 mm
Weight350 g (sensor + 3 m cable)
Internal MemoryCalibration history and sensor metadata storage
ComplianceDesigned for ASTM D1293, ISO 10523, ISO 5814, USP <791>, and GLP/GMP-aligned data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
Model110 Series
Cable Length Options15–100 m (aluminum frame) or 120–500 m (acrylic tripod)
Operating Temperature−30 °C to +75 °C
Temperature Range−15 °C to +80 °C
Temperature Accuracy< ±0.1 °C
Probe Material316 stainless steel & nickel-plated brass
Probe DimensionsØ15 mm × 180 mm
IP Rating (Probe)IP68
IP Rating (Handle/Display Unit)IP64
Power Supply4 × 1.5 V AA batteries
DisplayHigh-contrast LCD with tactile waterproof keypad
Acoustic & Visual Contact DetectionYes
Optional Bottom Sensor for Depth MeasurementYes
CalibrationFactory-calibrated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelEHAN
Measurement PrincipleComposite Electrode (Pt Working Electrode / Ag/AgCl Reference Electrode with Colloidal KCl Electrolyte)
ORP Range−1000.0 to +1000.0 mV
ORP Resolution±0.1 mV
ORP Accuracy±10 mV
Temperature SensingNTC Thermistor
Temp. Range0.00–50.00 °C
Temp. Resolution0.01 °C
Temp. Accuracy±0.5 °C
Response Time (t₉₀)<5 s
Output InterfaceModbus RTU over RS-485 (standard), SDI-12 (optional)
Supply Voltage5–12 V DC
Quiescent Current25 µA
Active Current (1 measurement/s)20 mA (RS-485 or SDI-12)
Pulse Current (Heating Activation)500 mA
Heating Pulse Duration100 ms
Operating Pressure≤5 bar
Housing MaterialsPVC, POM-C, Platinum, Polyurethane
Cable3 m armored polyurethane-sheathed cable with 9-pin connector (bare leads or waterproof Fischer-type)
Dimensions (installed, without gland)262 mm
(with compression gland)324 mm
Weight350 g (sensor + cable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelMES5
Measurement PrincipleInfrared Absorption (870 nm, 5 mm optical path)
SS Range0–50 g/L
Turbidity Range0–4000 FAU
Sludge Interface Range0–100 % IR transmittance
SS Resolution0.01 g/L
Turbidity Resolution0.01–1 FAU
Interface Resolution0.01–0.1 %
SS Accuracy<10%
Turbidity Accuracy±5% (200–4000 FAU)
Interface Accuracy±2%
Response Time<35 s
Temperature MeasurementNTC thermistor, –5.00 to +60.00 °C, ±0.5 °C accuracy, 0.01 °C resolution
Storage Temp–10 to +60 °C
IP RatingIP68
CommunicationModbus RTU over RS485 or SDI-12
Data Update Interval<1 s
Power Supply5–28 V DC
Standby Current25 µA @ 5 V
Active Current (RS485/SDI-12, 1 Hz)4.5 mA @ 5 V
Pulse Output Current100 mA (30 ms)
Heating Activation Time100 ms
Sensor Mass750 g
Housing MaterialsDelrin®, nickel-plated brass, EPDM elastomer
Pressure Rating5 bar
Cable Options9-pin waterproof connector with polyurethane jacket & bare leads, or Fisher waterproof connector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUAREAD
OriginUnited Kingdom
ModelAquasonde-2000 / Aquasonde-5000 / Aquasonde-7000
Detection ParametersDissolved Oxygen (DO), Conductivity (Relative & Absolute), pH, ORP, TDS, Temperature, Salinity, Depth, Resistivity, Specific Conductance (SSG)
Ingress ProtectionIP68
Depth Range0.075–100 m (profiling), 0–30 m (long-term submersion)
Operating Temperature−5 °C to +70 °C
Data Storage Capacity150,000 full datasets
Battery LifeUp to 180 days (model- and configuration-dependent)
Sampling FrequencyProgrammable from 0.5 Hz to once per 120 hours
Sensor Interfaces2 (AS-2000), 4 (AS-5000), 6 (AS-7000)
Auto-Cleaning SystemIntegrated only on AS-7000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
Model575-LTC
Instrument TypePortable
Temperature Range–5 to +50 °C (optional –5 to +70 °C)
Conductivity Range0–200,000 µS/cm
Water Level Range0–300 m
Accuracy (Water Level)<0.05% FS
Accuracy (Temperature)<0.1 °C
Accuracy (Conductivity)<0.5% of reading (min. 2 µS/cm)
Resolution (Water Level)1 cm (optional 1 mm)
Resolution (Temperature)0.1 °C (optional 0.01 °C)
Resolution (Conductivity)0.0005% FS
Long-term Stability (Water Level)<0.05%/year
Long-term Stability (Temperature)<0.02 °C/year
Battery Life~3 million measurements (~10 years at 2-min interval)
Memory4 MB Flash
Cable Lengthup to 500 m (optional)
Probe Depth Rating300 m
Housing Material316 stainless steel & titanium alloy
Ingress ProtectionIP68
InterfaceRS-232, USB
Data FormatsHT-Standard, Excel (.xlsx), *.zrxp, Labdüs (*.lgd), *.uvf
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelPASTEL UV
Instrument TypePortable/HANDHELD Water Quality Analyzer
Measured ParametersOrganic Matter (COD, BOD, TOC, TSS), Specific Compounds (NO₃⁻, Detergents)
Spectral Range200–350 nm
Optical Path Lengths5 mm and 10 mm
Detection Limits (10 mm path)COD: 1–350 mg/L, BOD: 0.2–350 mg/L, TOC: 0.5–300 mg/L, TSS: 2.5–100 mg/L, Detergent: 0.5–60 mg/L, NO₃⁻: 0.5–40 mg/L, NO₃⁻-N: 0.11–9.03 mg/L
Display64 × 128 pixel monochrome LCD
InterfaceRS232C bidirectional
PowerInternal rechargeable battery (≥100 measurements per charge)
Dimensions (L×W×H)35 × 17 × 20 cm
Weight9 kg
Max. Power Consumption35 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelUVILINE 9300 / UVILINE 9600
Wavelength Range320–1100 nm (9300) / 190–1100 nm (9600)
Light SourceTungsten-Halogen Lamp (9300) / Xenon Flash Lamp (9600)
Spectral Bandwidth4 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.5 nm
Absorbance Range±3500 Abs
Absorbance Resolution0.001 Abs or 0.1% T
Photometric Accuracy±0.003 Abs (0.5 Abs), ±0.005 Abs (1.0 Abs), ±0.010 Abs (2.0 Abs)
Stray Light<0.1% T at 340 nm (GG375), <0.05% T at 340 nm (GG375) for 9600
Baseline Stability±0.002 Abs
Scan Speed>600 nm/min (9300), >800 nm/min (9600)
InterfaceUSB-A, USB-B, RJ45
IP RatingIP30
Power Supply110–220 V, 50/60 Hz
Operating Temperature10–35 °C
Dimensions404 × 197 × 314 mm
Weight4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
ModelSkidsens
Probe DimensionsØ28 mm × 190 mm
Connection3/4″ T-fitting
Cable Length1.5 m
Output4–20 mA (max. 250 Ω), fouling potential measurement
Power Supply24 VDC / 50 mA
Measured ParameterFouling Potential (0–1 u.a.)
Process Temperature Range0–60 °C (32–140 °F)
Max. Pressure5 bar (72.5 psi)
Minimum Flow Rate (for Ø25.4 mm pipe)>1000 L/h (>4.4 GPM)
Max. Temperature Ramp Rate10 °C/min
Ambient Operating Temperature5–50 °C
Relative Humidity0–90 % RH
CertificationCE
Housing MaterialsPVC, 316L stainless steel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUAREAD
OriginUnited Kingdom
ModelAP-700 & AP-800
IP Rating (Sensor)IP68
IP Rating (Aquameter Display Unit)IP67
Cable Length3 m
Parameters MeasuredpH, ORP, Conductivity, Dissolved Oxygen (DO), Temperature, Turbidity (AP-800 only)
ComplianceCE, RoHS, UKCA
Housing MaterialMarine-grade anodized aluminum
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAquaread
OriginUnited Kingdom
ModelAP-2000
Measurement Parameters (Standard)Optical Dissolved Oxygen, pH, ORP, Electrical Conductivity (EC), Temperature
Optional Add-onsOne Ion-Selective Electrode (e.g., NH₄⁺, NH₃-N, Cl⁻, F⁻, NO₃⁻, Ca²⁺) + One Optical Sensor (e.g., Chlorophyll-a, Phycocyanin, Turbidity, Hydrocarbon/Oil-in-Water)
Depth MeasurementAvailable in AP-2000-D variant with integrated pressure-based depth sensor
Data LoggingOnboard memory via Aquaread Logger software
GPS IntegrationBuilt-in high-sensitivity GPS module with WGS84 coordinate output
Data VisualizationExport-compatible with Google Maps and Google Earth (KML/KMZ)
Compliance ContextDesigned for field-deployable environmental monitoring per ISO 5667 (water sampling), ASTM D3370 (field measurement practices), and EPA Method 160.1 (pH/EC/DO field protocols)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALABO
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSTAC Online Water Quality Early-Warning System
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0