Empowering Scientific Discovery

Shanghai Yifeng Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEDC
OriginUSA
ModelHD-1100
Measurement Range0.01–20 / 200 mg/m³
Resolution0.01 mg/m³
Accuracy±10%
Relative Error±10%
Display3.5" LCD
Unitsmg/m³
Calibration StandardNIOSH Method 0600
Particle Size Range0.01–50 µm
Power Supply6 VDC NiMH Rechargeable Battery
Operating Time>8 hours
Charging Time10–12 hours
Output Signal0–2 V analog
Max Operating Humidity95% non-condensing
Dimensions22.9 × 7.6 × 3.8 cm
Weight0.91 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEDC
OriginUSA
ModelEPAM-5000
Measurement PrincipleIntegrated Optical Scattering & Gravimetric Filtration
Safety RatingNon-Explosive
Measurement Range0.01–200.0 mg/m³
Resolution0.01 mg/m³
Accuracy±0.003 mg/m³
Relative Error±0.003 mg/m³
Particle Size Range0.1–100 µm
Flow Rate1.0–5.0 L/min
Filter Diameter47 mm FRM-compliant
Alarm Output90 dB at 3 ft
Analog Output0–2 VDC
Data Logging Interval1 sec to 30 min
Memory Capacity21,600 data points
Internal Clock Backup>5 years
Operating Temperature–10 °C to +50 °C
Storage Temperature–20 °C to +70 °C
Humidity Range≤95% RH non-condensing
Dimensions (H×W×D)35.6 × 15.2 × 25.4 cm
Weight5.4 kg
PowerRechargeable battery (24 h runtime) or AC adapter (22 h recharge time)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEDC
OriginUSA
ModelAir Aide AA-3500
Measurement PrincipleNephelometric Light Scattering (90° detection geometry)
Safety RatingNon-explosion-proof
Measurement Ranges0.001–20.0 mg/m³ and 0.01–200 mg/m³ (user-selectable dual range)
Resolution0.001 mg/m³
Accuracy (2σ stability)±0.004 mg/m³
Temperature Drift (2σ)±0.0025 mg/m³/°C
Analog Output0–2 VDC
CertificationsCE, ETL
Sampling Inlet OptionsPM₁₀, PM₂.₅, PM₁.₀, and Respirable Dust (4.5 µm D₅₀ cutoff)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEDC
OriginUSA
ModelVDM-7500
Measurement PrincipleVideo Imaging + Gravimetric Reference Correlation
Safety RatingNon-Explosive (Non-Intrinsically Safe)
Measurement Range0.01–200 mg/m³
Resolution0.01 mg/m³
Accuracy±10% (vs. NIOSH-approved gravimetric filter method)
Particle Size Detection Range0.1–100 µm
Flow Rate1.0–3.3 L/min
Data Logging Capacity21,500 points
Sampling Interval1 s to 10 min
Operating Temperature0–50 °C
Battery Life>8 h (NiMH rechargeable)
Dimensions (Main Unit)13.7 × 8.4 × 6.8 cm
Weight0.68 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0