Empowering Scientific Discovery

Shanghai Yifeng Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
Model7851
Calibration AerosolDolomite Powder (0.25–32 µm)
Aerosol Generation MethodPneumatic Dispersion via High-Pressure Nozzle System (up to 6 bar)
Software PlatformLabVIEW-based 32-/64-bit Calibration Suite
Compliance SupportISO 21501-4, ISO 14644-1, USP <788>, GLP/GMP-aligned Audit Trail Capabilities
Accessories7853 Indoor Air Calibration Kit, 7856 Dolomite Powder (0.4 kg), 7910 High-Pressure Disperser (4-nozzle, 6 bar)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
Model7811
Power SupplyAC 100–240 V, 50–60 Hz, max. 1.7 A
Protection ClassIEC Class 1 (grounded)
Fuse2.0 A, T-type, 5 × 20 mm, 250 VAC
Operating Temperature0–40 °C
Storage/Transport Temperature−20–50 °C
Relative Humidity (operating)≤90 % RH, non-condensing (instrument temperature ≥ ambient & aerosol temperature)
Max. Altitude2000 m
Dimensions (D×W×H)325 × 310 × 280 mm
Weight11.0 kg
Aerosol Output PressureAmbient pressure only — direct connection to downstream instruments prohibited
Aerosol MaterialsAqueous NaCl, PSL suspensions, DEHS, DOP (with dedicated nozzle), PAO, Emery 2003
Nozzle CountUp to 6 interchangeable nozzles
Primary Aerosol Flow Rate~2.5–7.0 L/min
Dry Air Flow Rate~7.5–17.0 L/min (customizable)
Nozzle Liquid Capacity3–10 mL per nozzle
Particle Concentration>10⁷ #/cm³ (DEHS), >10⁵ #/cm³ (NaCl, ~0.025 mg/cm³)
Particle Size RangeDEHS: ~80–350 nm
NaCl~10–200 nm
PSL~50–5000 nm
Sample CompatibilityMonodisperse and polydisperse aerosols
ComplianceDesigned for ISO 14644-3, ISO 21501-4, ASTM F51, USP <788>, EN 1822 test protocols
Software InterfaceAnalog output (0–10 V) for real-time flow monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGRIMM
OriginGermany
Model7860 NANO WOx
Particle Size Range1.2–20 nm
Generation PrincipleThermal Vaporization & Controlled Oxidation of Tungsten Filament
Gas Supply RequirementExternal, Triple-Stream Mass Flow Controlled
ComplianceDesigned for ISO 14644-3, ISO 27498, and EU GMP Annex 1 aerosol challenge testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJing
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMini CAST
PricingUpon Request
Aerosol Generation PrincipleDiffusion Flame / Premixed Flame Combustion
Particle Size Range10–200 nm
Particle Number ConcentrationUp to 1×10⁸ particles/cm³
Fuel EfficiencyOptimized for Low Consumption
Control InterfacePC-based Automated Software
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0