| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | LISA SAC 254 |
| Measurement Principle | UV absorbance at 254 nm (SAC₂₅₄) and visible reference at 530 nm |
| Light Source | Dual LED (254 nm UV-C, 530 nm green) |
| Detector | Filtered photodiode |
| Path Length Options | 1, 2, 5, 10, or 50 mm |
| Output Interfaces | Ethernet (TCP/IP), RS-232/RS-485 (Modbus RTU, TriOS protocol), 4–20 mA analog |
| Turbidity Compensation | Internal dual-wavelength correction (530 nm channel) |
| Accuracy | ±0.2% FS |
| Response Time | 4 s |
| Measurement Interval | 2 s |
| Data Logging Capacity | 2 MB (T100 format) |
| Operating Temperature | 2–40 °C (sample & ambient) |
| Storage Temperature | −20–80 °C |
| Flow Velocity Range | 0.1–10 m/s |
| Max. Pressure (SubConn) | 30 bar |
| Max. Pressure (Fixed Cable) | 3 bar |
| Max. Pressure (Flow Cell) | 1 bar (2–4 L/min) |
| Enclosure Material | Stainless Steel 1.4571 / 1.4404 or Titanium Grade 3.7035 |
| IP Rating | IP68 |
| Power Supply | 12–24 VDC (±10%) |
| Power Consumption | ≤1 W |
| Dimensions (10 mm path) | 300 mm × 48 mm |
| Weight (10 mm, stainless steel) | 1.6 kg |
| Compliant With | ISO 7027 (turbidity correlation), ASTM D5540 (SAC-based organic carbon estimation), EN ISO 8466-1 (calibration linearity), FDA 21 CFR Part 11-ready data logging (via TriOS software) |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | CO2-Pro™ |
| Measurement Principle | Membrane Equilibration with NDIR Detection |
| Standard Range | 0–600 µatm (extendable to 0–2000 µatm) |
| Accuracy | ±0.5% of reading |
| Resolution | 0.01 ppm (equivalent to 0.01 µatm) |
| Response Time (t₆₃) | 2.5 min (with integrated pump) |
| Operating Depth | Up to 50 m |
| Housing Material | Acetal (POM) |
| Temperature Range | 0–30 °C (standard), –2–20 °C (polar), 15–40 °C (tropical) |
| Power Input | 10–18 VDC |
| Power Consumption | 4 W (10 W during warm-up, including SBE 3K pump) |
| Data Output | RS-232 (ASCII), optional 0–5 V analog or 4–20 mA |
| Sampling Interval | Configurable down to 1 s |
| Internal Storage | 2 GB microSD card |
| Weight | 6.5 kg in air / 0.5 kg in water |
| Dimensions | 33 cm length × 19 cm diameter |
| Pressure/Temperature/Humidity Compensation | Automatic and embedded |
| Zero Calibration | Automatic Zero Point Calibration (AZPC) with onboard CO₂ scrubber |
| Biofouling Resistance | Fully membrane-isolated optical path |
| Compliance | Designed for GLP-aligned long-term deployments |
| Brand | CTG |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ERAS |
| Pricing | Available Upon Request |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Mini CO2 |
| Measurement Principle | Membrane Equilibration with NDIR Detection |
| CO₂ Range | 0–2000 ppm (extendable to 0–100% vol) |
| TDGP Range | 0–2 bar |
| Accuracy | ±2% of full scale (pCO₂), ±1% FS (TDGP) |
| Response Time (t₆₃) | 3 min |
| Resolution | 0.1% of full scale |
| Operating Depth | 600 m (acetal housing), 6000 m (titanium housing) |
| Dimensions | 28 cm × 5.3 cm (L × Ø) |
| Weight in Air | 0.53 kg |
| Weight in Water | 0.06 kg |
| Temperature Range | –2 °C to +35 °C |
| Power Input | 7–24 VDC (digital), 12–24 VDC (analog) |
| Power Consumption | 0.45 W (digital), 0.6–0.9 W (analog) |
| Data Output | RS-232 (ASCII CSV), 0–5 V or 4–20 mA |
| Sampling Interval | Configurable down to 2 s |
| Internal Storage | 2 GB microSD |
| Pressure/Temperature/Humidity Compensation | Automatic |
| Compliance | Designed for ASTM D5176, ISO 14687, and GLP-aligned long-term environmental monitoring deployments |
| Brand | CTG |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UviLux FUEL-BTEX |
| Instrument Type | Online |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 3.0–50,000 ppb (as BTEX-equivalent) |
| Detection Limit | 20 ppb (LOD) |
| Accuracy | ±3% of reading |
| Resolution | 3 ppb |
| Measurement Frequency | 10 Hz |
| Sensitivity (QSU) | 0.06 QSU/ppb |
| Calibration Range | 0–600 QSU |
| Max Operating Depth | 1000 m |
| Operating Temperature | −2 °C to 40 °C |
| Storage Temperature | −40 °C to 70 °C |
| Dimensions | Ø70 mm × 149 mm |
| Weight | 800 g (air), 150 g (water) |
| Housing Material | Acetal C |
| Connector | MCBH6MP (wet-mateable) |
| Supply Voltage | 9–36 V DC |
| Power Consumption | <1 W @ 12 V |
| Brand | SEBA |
|---|---|
| Origin | Germany |
| Model | KLL / KLL-T / KLL-Mini |
| Cable Options | 10–500 m |
| Depth Accuracy | ≤1 cm (up to 300 m) |
| Temperature Accuracy | ±0.10 °C (0–25 °C), ±0.15 °C (0–50 °C) |
| Conductivity Ranges | 4 selectable (20 μS/cm – 50 mS/cm) |
| Power | 6 V DC (KLL/KLL-T, 4 × 1.5 V AA) or 3 V DC (KLL-Mini, 2 × 1.5 V AA) |
| Operating Temp | −15 °C to +50 °C |
| Storage Temp | −40 °C to +80 °C |
| IP Rating | IP68 (probe), IP52 (reel) |
| Probe Diameter | 10–16 mm |
| Display | 8-character LCD (KLL-T) |
| Language Support | English, German, French, Spanish |
| Reel Material | Heat-resistant polymer |
| Frame Material | Anodized aluminum |
| Cable | PE-sheathed dual-steel-core corrosion-resistant cable |
| Brand | Sea-Bird Scientific |
|---|---|
| Origin | USA |
| Manufacturer | WET Labs (designed and manufactured) |
| Model | ECO Series |
| Instrument Type | Submersible Optical Sensor Platform |
| Deployment Modes | Profiling, Moored, Buoy-Mounted, Handheld (via optional interface) |
| Compliance | IP68 rated, ASTM D3921-22 (for turbidity), ISO 10264-2 (for chlorophyll-a fluorescence calibration traceability), GLP-compliant data logging |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | LISA 254 |
| Instrument Type | Online Analyzer |
| Measurement Principle | UV Absorption Spectrophotometry at 254 nm |
| Wavelength | 254 nm |
| Measurement Range | 10–5000 mg/L COD<sub>eq</sub> |
| Accuracy | ±5% of reading |
| Repeatability | ±5% RSD |
| LOD | 0.01 mg/L COD<sub>eq</sub> |
| Measurement Interval | 1 s |
| Batch Capacity | 15 samples |
| Optical Path Length Options | 1, 2, 5, 10, or 50 mm |
| Turbidity Compensation | Dual-channel (254 nm + 530 nm) |
| Output Interfaces | 4–20 mA analog, Ethernet (TCP/IP), RS-232/RS-485 (Modbus RTU, TriOS protocol) |
| Power Supply | 12–24 VDC (±10%), ≤1 W |
| Operating Temperature | 2–40 °C (sample & ambient) |
| Pressure Rating | Up to 30 bar (SubConn), 3 bar (fixed cable), 1 bar (flow cell) |
| Enclosure Material | Stainless Steel (1.4571 / 1.4404) or Titanium (3.7035) |
| IP Rating | IP68 |
| Dimensions (10 mm path) | 300 mm × 48 mm |
| Weight (10 mm path, stainless steel) | 1.6 kg |
| Brand | Wetlabs |
|---|---|
| Origin | USA |
| Model | ECO-Fl |
| Measurement Principle | In-situ optical fluorescence detection at 470 nm excitation / 695 nm emission |
| Detection Range | 0–60, 0–125, or 0–250 µg/L (user-selectable) |
| Sensitivity | 0.02 µg/L |
| Housing Material | Acetal polymer (seawater-corrosion resistant) |
| Dimensions | Ø63 × 127 mm |
| Depth Rating | 600 m standard, optional 6000 m |
| Weight | 0.4 kg in air / 0.02 kg in water |
| Digital Output | RS-232, 19200 baud, 12-bit resolution |
| Analog Output | 0–5 V |
| Internal Data Logging | Optional, up to 65,000 samples |
| Power Input | 7–15 VDC |
| Current Draw | 80 mA (active), 85 µA (sleep mode) |
| Sampling Rate | 8 Hz |
| Anti-fouling | Optional copper-brush wiper with programmable cycle |
| Connector | SUBCONN Micro 5-pin male |
| Optional Accessories | Handheld terminal, biofouling barrier, integrated battery pack |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | NICO plus |
| Measurement Principle | UV Absorption Spectrophotometry (254 nm) |
| Optical Path Length | 10 mm |
| Detection Method | Dual-wavelength (254 nm + reference) |
| Calibration | Built-in temperature compensation |
| Interface | G2 Web-enabled Ethernet interface |
| Compliance | DIN EN ISO 7027 (turbidity), ASTM D5540 (UVT), USP <643> (TOC estimation), GLP/GMP-ready data logging |
| Sample Handling | In-situ, flow-through or immersion mode |
| Reagent-Free | Yes |
| Optical Window | Nano-coated quartz |
| Data Storage | Internal SD card (optional), real-time streaming via Modbus TCP/RTU, HTTP API |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Mini CH4™ |
| Measurement Principle | Membrane Inlet Non-Dispersive Infrared (NDIR) Spectroscopy |
| CH₄ Range | 0–1% v/v, 0–10% v/v, or 0–100% v/v (user-selectable) |
| TDGP Range | 0–2 bar |
| Accuracy | ±3% FS (CH₄), ±1% FS (TDGP) |
| Stabilization Time (t₆₃) | 8 min (with pump head) |
| Resolution | 0.1% FS |
| Depth Rating | 600 m (acetal housing), 6000 m (titanium housing) |
| Operating Temperature | −2 °C to 35 °C |
| Power Input | 7–24 VDC (digital), 12–24 VDC (analog) |
| Power Consumption | 0.45 W (digital), 0.6–0.9 W (analog) |
| Data Output | RS-232 (ASCII CSV), 0–5 V analog, or 4–20 mA |
| Sampling Interval | Configurable down to 2 s |
| Internal Storage | 2 GB microSD card |
| Housing Material | Acetal or Grade 5 Titanium (Ti-6Al-4V) |
| Weight in Air | 0.53 kg |
| Weight in Water | 0.06 kg |
| Dimensions | 28 cm L × 5.3 cm Ø |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | OPUS UV |
| Light Source | Xenon lamp |
| Detector | 256-channel miniature spectrometer (200–360 nm, 0.8 nm/pixel) |
| Measurement Principle | Absorption spectroscopy (attenuation-based) |
| Optical Path Lengths | 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 50 mm |
| Turbidity Compensation | Yes |
| Data Memory | 2 GB internal |
| Measurement Interval | ≥1 minute |
| Output Interfaces | RS232 or RS485 |
| Power Consumption | ≤8 W |
| Housing Material | Stainless steel or titanium alloy (seawater-resistant) |
| Dimensions | Ø48 × 470 mm |
| Weight | 3 kg (stainless steel, 10 mm path) |
| Pressure Rating | 30 bar (with SubConn connector), 3 bar (fixed cable), 1 bar (flow cell, 2–4 L/min) |
| Ingress Protection | IP68 |
| Sample Temperature Range | 2–40 °C |
| Ambient Temperature Range | 2–40 °C |
| Storage Temperature Range | −20–80 °C |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | OPUS HS |
| Type | Online Analyzer |
| Optical Principle | UV Absorption Spectrophotometry (200–360 nm) |
| Light Source | Pulsed Xenon Lamp |
| Detector | 256-channel Miniature Spectrometer |
| Spectral Resolution | 0.8 nm/pixel |
| Optical Path Lengths | 0.3, 1, 2, 5, 10, 50 mm |
| Turbidity Compensation | Yes |
| Data Storage | 2 GB internal |
| Measurement Interval | ≥1 min |
| Output Interfaces | RS232 / RS485 |
| Power Consumption | ≤8 W |
| Housing Material | Stainless Steel or Titanium Alloy |
| Dimensions | Ø48 × 470 mm |
| Weight | 3 kg (stainless steel, 10 mm path) / 2 kg (titanium, 10 mm path) |
| Pressure Rating | 30 bar (SubConn connector), 3 bar (fixed cable), 1 bar (flow cell, 2–4 L/min) |
| IP Rating | IP68 |
| Operating Temperature (Sample) | 2–40 °C |
| Ambient Temperature | 2–40 °C |
| Storage Temperature | −20–80 °C |
| Compliance | Designed for continuous operation in wastewater, drinking water, and industrial effluent monitoring per ISO 7027 (turbidity), ASTM D515-18 (sulfide), and GLP/GMP-aligned data integrity practices |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | microFlu-HC |
| Measurement Principle | UV-induced fluorescence (255 nm excitation, 360 nm emission) |
| Target Analytes | Polycyclic Aromatic Hydrocarbons (PAHs) and total petroleum hydrocarbons (TPH) in water |
| Range | PAHs 0–5000 ppb, TPH 0–150 ppm |
| LOD | PAHs 5 ppb, TPH 0.15 ppm |
| Accuracy | ±10 % FS |
| Response Time (T90) | 6 s |
| Min. Measurement Interval | 3 s |
| Digital Interface | RS-485 / Modbus RTU |
| Analog Outputs | 4–20 mA (default), 0–5 V, 0–10 V |
| Power Supply | 12–24 VDC (±10 %) |
| Housing Material | Stainless Steel 1.4571/1.4404 or Titanium Grade 3.7035 |
| Dimensions | 162 mm × 48 mm |
| Weight | ~650 g (SS), ~510 g (Ti) |
| Max. Pressure Rating | 30 bar (SubConn), 3 bar (fixed cable), 1 bar (flow cell) |
| IP Rating | IP68 |
| Operating Temp. | +2 to +40 °C (sample & ambient) |
| Storage Temp. | −20 to +80 °C |
| Flow Rate Compatibility | 0.1–10 m/s |
| Optical Window | Nano-coated quartz |
| Turbidity Compensation | None |
| Data Logging | Internal storage not supported |
| Brand | Chelsea |
|---|---|
| Origin | UK |
| Model | LabSTAF |
| Excitation Wavelengths | 417, 452, 472, 505, 534, 594, 622 nm |
| Actinic Light Range | 10–2400 µmol photons·m⁻²·s⁻¹ (12-bit resolution) |
| Detection Limit | 0.001 mg/m³ Chl-a |
| Sample Chamber | 20 mL quartz vertical cylinder with BK7 base |
| Power Supply | 24 VDC, 140–400 mA (3.4–9.7 W) |
| Dimensions (H×D×W) | 235 × 320 × 420 mm |
| IP Rating | IP65 |
| Weight | 8.1 kg |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | EnviroFlu-HC |
| Instrument Type | Online |
| Measurement Principle | UV-Induced Fluorescence |
| Measurement Range | 0–5000 ppb (PAH) |
| Detection Limit | 0.3 ppb |
| Accuracy | ±1% of reading |
| Resolution | 0.1 ppb |
| Measurement Frequency | 1 Hz |
| Excitation Wavelength | 254 nm |
| Emission Wavelength | 360 nm |
| Housing Material | Stainless Steel 1.4571/1.4404 or Titanium Grade 3.7035 |
| Dimensions | 311 mm × 68 mm |
| Weight | 2.7 kg (stainless), 1.9 kg (titanium) |
| Pressure Rating | 30 bar (SubConn), 3 bar (fixed cable), 1 bar (flow cell) |
| Ingress Protection | IP68 |
| Operating Temperature | +2 °C to +40 °C (sample), –5 °C to +55 °C (ambient) |
| extended accuracy range | 0–40 °C |
| Flow Velocity | 0.1–10 m/s |
| Power Supply | 12–24 VDC (±10%) |
| Power Consumption | ≤3.5 W |
| Output Interfaces | RS-232 (TriOS protocol), 4–20 mA, 0–5 V |
| Response Time (T₁₀₀) | ≤10 s |
| Calibration Interval | 24 months |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | OPUS aero |
| Optical Path Lengths | 0.3 mm, 1 mm, 2 mm |
| Nitrate-N (NO₃-N) Range | 2.4–120 mg/L (0.3 mm), 0.7–36 mg/L (1 mm), 0.35–18 mg/L (2 mm) |
| Nitrite-N (NO₂-N) Range | 4.4–220 mg/L (0.3 mm), 1.3–67 mg/L (1 mm), 0.65–33.5 mg/L (2 mm) |
| Wavelength Range | 200–360 nm |
| Resolution | 0.8 nm/pixel |
| Detector | 256-channel Miniature Spectrometer |
| Light Source | Xenon Flash Lamp |
| Turbidity Compensation | Yes |
| Accuracy | ±(5% + 0.1 mg/L) |
| Response Time | 2 min |
| Minimum Measurement Interval | 1 min |
| Housing Material | Stainless Steel 1.4571 / 1.4404 |
| Dimensions | 470 × 48 mm |
| Weight | ~3 kg |
| Digital Interfaces | Ethernet (TCP/IP), RS-232/RS-485 (Modbus RTU) |
| Power Supply | 12–24 VDC (±10%) |
| Max. Power Consumption | ≤8 W |
| Pressure Rating | 3 bar (fixed cable), 1 bar (flow cell, 2–4 LPM) |
| IP Rating | IP68 |
| Operating Temperature | +2 to +40 °C (sample & ambient), -20 to +80 °C (storage) |
| Flow Velocity | 0.1–10 m/s |
| Calibration Interval | 24 months |
| Data Storage | 2 GB internal |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | microFlu CDOM |
| Light Source | High-efficiency blue LEDs (370 nm) with internal reference photodiode |
| Detector | Photodiode (460 nm, 20 nm FWHM) |
| Measurement Range | 0–20 μg/L and 0–200 μg/L (dual-range auto-adaptive) |
| Detection Limit | 0.02 μg/L |
| Resolution | 0.02 μg/L |
| Accuracy | ±3% of reading |
| Housing | Marine-grade stainless steel (corrosion-resistant to seawater) |
| Dimensions | Ø48 × 200 mm |
| Weight | 0.5 kg |
| Pressure Rating | 500 m water depth |
| Electrical Interface | RS-232 and 0–5 V analog output |
| Connector | SUB-CONN Micro 5-pin male |
| Brand | In-situ Marine |
|---|---|
| Origin | Australia |
| Model | CTD-Optics Series |
| Measurement Principle | High-stability quartz crystal conductivity cell, PT1000 RTD temperature sensor, piezoresistive pressure transducer |
| Data Logging | 16 GB microSD (timestamped binary + ASCII log files) |
| Power Management | Integrated 11.1 V / 7.8 Ah Li-ion battery with programmable sleep mode (65 µA) |
| Communication | Triple RS-232 channels (configurable baud rate 9600–115200 bps), optional Wi-Fi download & 4G telemetry via C-TEL interface |
| Compliance | IP68 rated housing |
| Environmental Rating | Long-term submersible deployment up to 100 m depth |
| Operating Temperature | 0–40 °C (ambient) |
| sensor range | −55 to +125 °C (temperature), 0–100 m (depth), 0–100,000 µS/cm (conductivity) |
| Brand | Pro-Oceanus |
|---|---|
| Origin | Canada |
| Model | Solu-Blu CH4 |
| Measurement Principle | Membrane Inlet Non-Dispersive Infrared (NDIR) |
| CH₄ Range | 0–30 mg/L (switchable to 0–3 mg/L and 0–300 µg/L) |
| TDGP Range | 0–2 bar |
| Accuracy | ±3% of full scale (pCH₄), ±0.1% FS (TDGP) |
| Response Time (t₆₃) | 10 min |
| Resolution | 0.1% of full scale |
| Operating Depth | 0–50 m |
| Temperature Range | 0–35 °C |
| Power Input | 7–24 VDC |
| Power Consumption | 90 mW (RS-232 + 0–5 V), 300–600 mW (RS-232 + 4–20 mA) |
| Output | RS-232 (ASCII), 0–5 V analog, or 4–20 mA analog |
| Sampling Interval | Configurable down to 2 s |
| Dimensions | 19.68 cm (L, sensor only), 25.68 cm (L with connector) |
| Weight | 0.47 kg |
| Housing Material | Acetal (POM) |
| Standard Cable | 3 m integrated |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | LISA color |
| Optical Path Lengths | 50 mm, 100 mm, 150 mm, 250 mm |
| Measurement Principles | Absorption-based attenuation at dual-wavelength LED pairs (e.g., 436 nm & 740 nm) |
| Compliance Standards | DIN EN ISO 7887:2012-04 (Methods B & C), DIN EN ISO 6271-2:2005-03, GOST 3351-74 |
| Measured Parameters | SAC (436/525/620 nm), True Color (410 nm), Hazen/APHA (390/455 nm), Cr-Co (380/413 nm) |
| Turbidity Compensation | Yes, via 740 nm reference channel |
| Accuracy | ±0.5 % of reading |
| Response Time | 4 s |
| Minimum Measurement Interval | 2 s |
| Housing Materials | Stainless Steel 1.4571 / 1.4404 or Titanium Grade 2 (3.7035) |
| Dimensions (L × Ø) | 340 mm × 48 mm (for 50 mm path) |
| Weight | ~2.4 kg (stainless), ~1.3 kg (titanium) |
| Digital Interfaces | Ethernet (TCP/IP), RS-232/RS-485 (Modbus RTU) |
| Analog Output | 4–20 mA |
| Power Supply | 12–24 VDC (±10 %), ≤1 W |
| Max. Pressure Rating | 30 bar (SubConn), 3 bar (fixed cable), 1 bar (flow cell) |
| IP Rating | IP68 |
| Operating Temperature | +2 °C to +40 °C |
| Storage Temperature | −20 °C to +80 °C |
| Flow Velocity Range | 0.1–10 m/s |
| Data Memory | ~2 MB |
| Calibration Interval | 24 months |
| Optical Window | Nano-coated sapphire |
| Cleaning Option | Optional pneumatic cleaning system |
| Brand | microLAN |
|---|---|
| Country of Origin | Netherlands |
| Model | BACTcontrol |
| Measurement Principle | Enzymatic Fluorescence Assay |
| Target Analytes | β-Galactosidase (coliforms), β-Glucuronidase (E. coli), Alkaline Phosphatase (total viable biomass) |
| Measurement Cycle | 1–2 h |
| Detection Method | Substrate-specific fluorogenic enzymatic reaction |
| Sample Flow Rate | 3 L/h |
| Sample Temperature Range | 10–35 °C |
| Ambient Operating Temperature | 15–30 °C |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
| Power Consumption | <100 W |
| Enclosure Rating | IP54 (optional IP65) |
| Dimensions (H×W×D) | 460 × 450 × 321 mm |
| Weight | 25 kg |
| Housing Material | Aluminum |
| Max. Sample Pressure | 0.05 bar |
| Interface | 2× USB 2.0 (Type A), 2× Gigabit Ethernet (RJ45), Modbus TCP/RTU, 2× digital inputs, 2× relay outputs, 1× 4–20 mA analog output |
| Optional | UMTS/ISDN modem slot, dual-sample inlet with auxiliary cleaning module, climate control unit (>30 °C ambient), automated NaOCl-based cleaning system (≤0.05% active chlorine) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | iTOXcontrol |
| Instrument Type | Online |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 5–40 °C |
| Reagent Temperature Range | 15–30 °C |
| Repeatability | Relative Error ≤5% |
| Sample Throughput | 10 mL/h (4.5 mL per test, 2 tests/h) |
| Measurement Duration | 40 min |
| Enclosure Rating | IP31 |
| Power Supply | 220 VAC, 50 Hz or 110 VAC, 60 Hz |
| Dimensions (D×W×H) | 50×50×110 cm (plus 73 cm with trolley) |
| Weight | 90 kg (excl. optional air conditioning unit: +20 kg) |
| Brand | Microwise |
|---|---|
| Origin | Denmark |
| Model | BallastWISE |
| Portability | Portable |
| Biological Target | Algal and zooplanktonic organisms |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Repeatability | ±1% |
| Sample Throughput | Per batch |
| Analysis Time | 5 s |
| Detection Principle | Dual-mode fluorescence imaging + motility-based viability assessment |
| Size Classes Quantified | 10–50 µm and >50 µm |