Simultaneous Thermal Analyzer
Filter
Showing 31–60 of 80 results
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-STA-200 |
| Origin | Shanghai, China |
| Type | Benchtop Simultaneous DSC-TGA Analyzer |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| DSC Sensitivity | <0.1 µW |
| TGA Resolution | 0.1 µg |
| Atmosphere Control | Dual-gas (N₂/air) with mass flow controller |
| Sample Capacity | Up to 200 mg |
| Compliance | ASTM E1131, ISO 11358, USP <641>, GB/T 19466 |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-STA-200 |
| Heating Rate | 1–80 °C/min |
| Temperature Range | Ambient to 1150 °C (extendable to 1350 °C) |
| Temperature Stability | ±0.1 °C |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Sample Capacity | Determined by Crucible Size |
| Vendor Type | Authorized Distributor |
| Brand | JUZEN |
|---|---|
| Model | JB-STA-200 |
| Origin | Shanghai, China |
| Type | Benchtop Simultaneous Thermogravimetric Analyzer with Differential Scanning Calorimetry |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 0.1–100 °C/min |
| Mass Resolution | 0.1 µg |
| DSC Sensitivity | <0.1 µW |
| Atmosphere Control | Dual-gas (N₂/air) with mass flow controller |
| Sample Capacity | Up to 200 mg |
| Compliance | ASTM E1131, ISO 11358, ISO 17516, USP <41>, GLP-ready data logging |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA HP L85 |
| Temperature Range | 170 °C to 1200 °C (optional 1600 °C / 1800 °C) |
| Temperature Stability | ±0.05 °C |
| Max Sample Mass | 35,000 mg |
| Operating Pressure | up to 150 bar |
| TGA Resolution | 0.1 μg |
| DSC Sensitivity | approx. 4–22.5 μW |
| DSC Resolution | 0.3–1 μW |
| DTA Resolution | 0.03 nV |
| Vacuum Level | ≤10⁻⁴ mbar (pump-dependent) |
| Sensor Types | E / K / S / B / C |
| Gas Control | Quantitative mass-flow-controlled inlet systems |
| Optional Accessories | Steam generator, top-loading modular sensor kits (TG-only or TG-DSC) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L81 |
| Temperature Range | −150 to 2400 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 5 g / ±2500 mg |
| Atmosphere Control | Vacuum (down to 10⁻² mbar), Pressure up to 5 bar (optional) |
| TG Resolution | 0.01–0.1 µg |
| DSC Sensor Types | E, K, S, B, C (C = DTA-only) |
| DSC Sensitivity | ~4–22.5 µW |
| DSC Resolution | 0.3–1.2 µW |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Resolution | 0.03 nV |
| DTA Range | ±250–±2500 µV |
| Optional Autosampler | 42-position |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L81 Nuclear |
| Temperature Range | −150 °C to 500 / 700 / 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | 0.001 °C |
| Maximum Sample Mass | ±35,000 mg |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| TG Resolution | 0.01 / 0.02 / 0.1 µg |
| DSC Resolution | 0.3 / 0.4 / 1 / 1.2 µW |
| DTA Resolution | 0.03 nV |
| DTA Sensitivity | 1.5 µV/mW |
| DTA Range | 250 / 2500 µV |
| Sensor Types | E / K / S / B / C (C = DTA-only) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L82 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 25 mg / 2500 mg |
| TG Resolution | 0.1 µg |
| DSC Sensitivity | ~4–17.6 µW |
| DTA Resolution | 0.03 nV |
| Vacuum Capability | 10⁻² mbar (≤800 °C) |
| Atmosphere Control | Inert, oxidative, reducing, humidified, or vacuum |
| Optional Autosampler | 42- or 90-position |
| Sensor Types | E/K/S thermocouples |
| Measurement Modes | TG, TG-DTA, TG-DSC, TG-DSC (Cp) |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA L87 MSB |
| Temperature Range | –196 to 2400 °C |
| Max. Sample Mass | 10 g (standard balance) |
| Resolution | 1 µg |
| Pressure Range | UHV to 150 bar (metal version) |
| Measurement Principle | Magnetic suspension coupling with PID-controlled electromagnetic levitation |
| Compliance Options | ASTM E1131, ISO 11358, USP <731>, GLP/GMP-ready data logging |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | STA/TGA L86 |
| Temperature Range | −150 °C to 500 / 700 / 1000 °C |
| Heating Rate | 0.01–100 K/min |
| Temperature Stability | ±0.001 °C |
| Maximum Sample Mass | 35 g |
| TG Resolution | 0.01–0.1 µg |
| DSC Resolution | 0.3–1.2 µW |
| DTA Resolution | 0.03 nV |
| Vacuum Capability | 10⁻² mbar (pump-dependent) |
| Pressure Range (optional) | up to 5 bar |
| Atmosphere Control | Inert, oxidizing, reducing, corrosive, and vacuum-compatible |
| Sensor Options | E/K/S/B/C (C-type for DTA only) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 |
| Temperature Range | RT to 1600 °C |
| Mass Resolution | Sub-microgram |
| Automation | Integrated Robotic Sample Changer |
| 炉 Atmosphere Control | Hermetic Furnace Design |
| Coupling Compatibility | MS and FTIR for Evolved Gas Analysis |
| Modular Architecture | Field-upgradable Hardware Modules |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-DSC300 |
| Temperature Range | Ambient to 600 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.01 °C |
| Atmosphere Control | Dual-gas automatic switching (instrument-controlled) |
| DSC Sensitivity | 0.001 mW |
| DSC Resolution | 0.01 µW |
| Temperature Accuracy | ±0.001 °C |
| Baseline Drift | <1 µW/30 min |
| Gas Flow Range | 0–300 mL/min (customizable) |
| Gas Pressure Rating | ≤5 MPa |
| Display | 7-inch 24-bit color TFT touchscreen |
| Data Interface | Standard USB 2.0 |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DZ-STA 200 |
| Heating Rate | 1–80 °C/min |
| Temperature Range | Ambient to 1150 °C (extendable to 1350 °C) |
| Temperature Stability | ±0.1 °C |
| Max Sample Weight | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-STA 300 |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Data Interface | USB |
| Display | 7-inch 24-bit LCD touchscreen |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | DZ-STA200 |
| Coupling Technique | TG-DSC |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DZ-STA200 |
| Price Range | USD 9,800–13,900 (FOB) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 2 g (expandable to 5 g) |
| Atmosphere Control | Inert, oxidizing, reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Calibration | Multi-point temperature & enthalpy calibration |
| Gas Control | Dual-channel mass flow control with integrated digital flow meters |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Crucible Options | Al₂O₃ ceramic, aluminum, platinum (optional) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| TG Sensitivity | 0.1 µg |
| DSC Sensitivity | 0.1 µW |
| DSC Range | ±1000 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit Color Touchscreen |
| Gas Control | Dual-channel Mass Flow Control with Built-in MFCs |
| Data Interface | Standard USB |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ-STA200 |
| Price Range | USD 11,200–14,000 (FOB) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 2 g (expandable to 5 g) |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Atmosphere System | Dual-channel mass flow control with integrated digital flow meters |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-STA200 |
| Price | ¥85,000 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Model | DZ-STA200 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| TG Resolution | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit LCD Touchscreen |
| Gas Control | Dual-channel mass flow control with integrated flow meters |
| Software | Integrated thermal analysis suite with TG, DTG, and TG-DSC overlay, calibration support (temperature & enthalpy), PDF/Excel export, audit-trail-capable data logging |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | DZ-STA200 |
| Price | ¥85,000 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 2 g (expandable to 5 g) |
| Atmosphere Control | Integrated dual-channel mass flow controller with adjustable flow rate and gas switching (inert, oxidizing, reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ-STA200 |
| Price Range | USD 11,200–16,800 (based on exchange rate ~¥80,000–¥120,000) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, oxidizing, reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Sensitivity | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Gas Control | Dual-channel mass flow control with integrated flow meters |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Calibration | Multi-point temperature and enthalpy calibration |
| Compliance Support | ASTM E1131, ASTM E1269, ISO 11358, ISO 17225, USP <1225>, GLP-compliant audit trail in software |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DZ-STA300 |
| Price Range | USD 16,800–21,000 (FOB) |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ-STA300 |
| Temperature Range | Ambient to 1550 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | STA 200 |
| Temperature Range | Ambient to 1200°C |
| Heating Rate | 0.1–100°C/min |
| Max Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Reducing |
| TG Resolution | 0.1 µg |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | ±0.01 mW |
| Temperature Accuracy | ±0.1°C |
| Temperature Resolution | 0.01°C |
| Cooling Time (1000°C → 100°C) | ≤15 min |
| Data Interface | USB |
| Display | 7-inch 24-bit LCD Touchscreen |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | STA200 |
| Price Range | USD 11,200–14,000 (FOB) |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.01 mg |
| TG Resolution | 0.1 µg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Gas Control | Dual-channel mass flow control with integrated digital flow meters |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit color touchscreen LCD |
| Calibration | Multi-point temperature and enthalpy calibration per ISO 11357 & ASTM E1269 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 2500 Regulus |
| Heating Rate | 0–100 °C/min |
| Temperature Range | RT to 1100 °C (standard furnace) / RT to 1600 °C (high-temperature furnace) |
| Temperature Stability | ±0.3 K |
| Maximum Sample Mass | 250 mg |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum (dynamic or static) |
| Gas Control | Integrated Mass Flow Controllers (MFCs), software-regulated |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 2500 Regulus |
| Temperature Range | RT to 1100°C (low-temperature furnace) / RT to 1600°C (high-temperature furnace) |
| Heating Rate | 0.001–100 °C/min (RT–1100°C) |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 1 g |
| Thermogravimetric Resolution | 0.03 µg |
| Temperature Accuracy | ±0.3 K |
| Atmosphere Options | Inert, oxidizing, reducing, vacuum (dynamic or static) |
| Vacuum Tightness | ≤10⁻⁴ mbar (≤10⁻² Pa) |
| Gas Control | Integrated mass flow controllers (MFCs) with software-defined flow programming |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 449 F3 Jupiter |
| Temperature Range | −150 to 2400 °C |
| Heating Rate | 0–50 °C/min (standard) |
| Temperature Stability | ±0.3 K |
| Maximum Sample Mass | 35 g |
| Balance Resolution | 0.1 µg |
| Vacuum Level | 10⁻⁴ mbar |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Optional Modules | TMDSC, Tau-R® Cp Calibration, BeFlat® Baseline Optimization, ASC Auto-sampler (20 positions), Coupling to FTIR/MS/GC-MS, Steam Furnace, Corrosive Gas Kit |