- All
- Favorite
- Popular
- Most rated
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | AHT |
| Application | Continuous Shore A Hardness Testing of Vulcanized Rubber |
| Sample Capacity | 20-position (upgradable to 30) automated sample carousel |
| Control | Fully software-driven test setup, data acquisition, and pass/fail evaluation |
| Compliance | ASTM D2240, ISO 7619-1, DIN 53505 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery HP-TGA 75 / 750 / 7500 |
| Temperature Range | Up to 1100 °C |
| Balance Sensitivity | 0.1 µg |
| Operating Environment | Controlled High-Pressure Atmosphere (up to 75, 750, or 7500 psi) |
| Instrument Type | Benchtop Integrated High-Pressure TGA System |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software architecture |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 550 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 1 g |
| Baseline Drift | <25 µg |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Affinity ITC / ITC Auto |
| Temperature Range | 2–80 °C |
| Cell Volume Options | 1.0 mL (standard) or 190 µL (low-volume) |
| Sample Throughput | Multi-sample via integrated 96-well autosampler |
| Temperature Control | Active solid-state heating/cooling with ±0.01 °C stability |
| Automation Level | Fully automated titration, injection, cleaning, and cell positioning |
| Compliance | Designed for GLP/GMP environments |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DuraPulse |
| Instrument Type | Dynamic Mechanical Durability Tester for Cardiovascular Devices |
| Compliance | ISO 5840-1:2021, ISO 5840-2:2021, ISO 5840-3:2021 |
| Test Stations | Configurable as 2-, 4-, or 6-channel modular units |
| Actuation Principle | Electromagnetic linear motor with closed-loop digital servo control |
| Waveform Fidelity | ≤ ±0.5% deviation from target physiological waveform (e.g., sinusoidal, pulsatile, or patient-specific waveforms) |
| Environmental Control | Independent, sealed test chambers with integrated temperature and fluid medium monitoring |
| Warranty | 10-year limited warranty on linear motor assemblies |
| Software Platform | DuraPulse Control Suite v4.x with audit trail and 21 CFR Part 11–compliant user access controls |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25P |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –130 °C to 550 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Pressure Range | 1 Pa to 7 MPa (0.0001–1,000 psi) |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | DIL 831 |
| Temperature Range | RT to 1700 °C |
| Heating Rate | Up to 50 °C/min |
| Temperature Accuracy | ±0.05 °C |
| Sample Length | 0–25 mm (standard), 12 mm (optimal) |
| Length Resolution | 1 nm |
| Force Range | 0.01–1.00 N |
| Force Resolution | 0.01 N |
| CTE Accuracy | ±0.03 × 10⁻⁶ K⁻¹ |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Rheo-IS |
| Application | In-situ rheo-electrochemical coupling for complex fluids |
| Compatibility | Designed exclusively for TA Instruments Discovery HR Hybrid Rheometers |
| Measurement Mode | Simultaneous dynamic oscillatory rheology and electrochemical impedance spectroscopy (EIS) |
| Operating Frequency Range (EIS) | 10 mHz – 10 MHz |
| Electrode Configuration | Integrated parallel-plate or cone-and-plate dual-function geometry with embedded platinum or stainless-steel working/counter electrodes |
| Temperature Control | Compatible with TA’s Peltier and environmental chamber systems (−40 °C to 200 °C) |
| Data Synchronization | Hardware-triggered, sub-millisecond time alignment between rheological and impedance data streams |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 805 |
| Temperature Range | −150 to 1300 °C |
| Maximum Heating Rate | ≤4000 °C/s |
| Measurement Resolution | 0.01 µm / 0.05 °C |
| Atmosphere Options | Air, Vacuum, Inert Gases (e.g., Ar, N₂, He) |
| Quench Medium | High-velocity Helium Gas |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 10 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TAM IV+Biologic |
| Pricing | Available Upon Request |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 806 |
| Measurement Principle | Non-contact shadow-edge optical imaging |
| Light Source | High-intensity GaN LED with collimated short-wavelength planar illumination |
| Detection | High-resolution CCD sensor with digital edge detection |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | 1400 °C → 50 °C in ≤10 min |
| Furnace Design | Dual-zone planar heating (top + bottom) for minimized axial and radial thermal gradients |
| Sample Area | 30 mm wide field-of-view with position-insensitive measurement |
| Compliance | ASTM E228, ISO 11359-1, USP <632>, GLP/GMP-ready data audit trail (via TRIOS software) |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | DIL 832 |
| Temperature Range | RT to 1700 °C |
| Heating Rate | Up to 50 °C/min |
| Temperature Accuracy | ±0.05 °C |
| Sample Length | 0–25 mm |
| Sample Diameter | ≤6 mm |
| Length Resolution | 1 nm |
| Force Range | 0.01–1.00 N |
| Force Resolution | 0.01 N |
| CTE Accuracy | ±0.01 × 10⁻⁶ K⁻¹ |
| Total Measurement Range | 5000 µm |
| Cooling Time (1000 °C → RT) | 13 min |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Discovery HR 30 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.05 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 55 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | <25 μg |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | MV one |
| Motor Speed Range | 0.1–10 rpm (standard test at 2 rpm) |
| Rotor Options | 38.10 mm (large) and 30.48 mm (small) diameter |
| Compliance | ASTM D1646, ISO 289, DIN 53523 |
| Temperature Control | High-precision, PID-regulated, ±0.1 °C stability |
| Torque Measurement | Auto-calibrating, high-resolution digital torque sensor |
| Frame | Ultra-rigid monolithic steel construction |
| Drive System | Direct-drive brushless motor with <0.01 rpm speed resolution |
| Software | Scarabaeus v5.x (multi-language, GLP-compliant audit trail, FDA 21 CFR Part 11 ready) |
Show next