Thermal Dilatometer
Filter
Showing 31–56 of 56 results
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Select |
| Temperature Range | −180 °C to 2000 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±10,000 µm / ±25,000 µm |
| Resolution | 1 nm / 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme HT |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁵ mbar) |
| Furnace Types | Graphite, Alumina, Fused Silica |
| Optional Features | c-DTA® (calibrated Differential Thermal Analysis), Identify™ Spectral Matching, Rate-Controlled Sintering (RCS) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Sample Types | Solid, Powder, Liquid |
| Furnace Configurations | Single or dual interchangeable furnaces |
| Patented Technologies | NanoEye displacement sensor, MultiTouch sample positioning, c-DTA® (optional), Identify spectral library (optional), Rate-Controlled Sintering (RCS, optional) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL 2000 Series |
| Max Operating Temperature | 1000 °C (DIL 2010), 1200 °C (DIL 2020), 1600 °C (DIL 2030) |
| Low-Temp Capability | Down to –196 °C (with LN₂ cooling option, DIL 2010C) |
| Sample Dimensions | Up to 50 mm length × 20 mm diameter |
| Repeatability | ±0.004 PLC |
| Heating Rate | 1–30 °C/min |
| Temperature Resolution | 0.1 °C |
| Atmosphere Control | Optional inert/vacuum/oxidizing gas environments |
| Calibration Standards | Included (fused quartz, α-alumina, NIST-traceable reference materials) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL2010C |
| Temperature Range | –170 °C to 500 °C (or RT to 1000 °C with standard configuration) |
| Max Sample Size | 50 mm length × 10 mm diameter |
| Furnace Type | Split-tube (clamshell) quartz tube furnace |
| Sample Holder & Pushrod | Fused silica |
| Thermocouple | Type N (sample & control) |
| Heating Rate | 1–30 °C/min |
| LVDT Linear Range | ±2.54 mm |
| LVDT Resolution | 0.02 µm |
| Contact Force | Adjustable |
| Cryogenic Assembly | Stainless-steel cold stage with vertical transfer tube, Dewar reservoir mounted above furnace |
| Ambient Protection | Acrylic enclosure with dry inert gas purge |
| Compliance | ASTM E228, ISO 11359-1/-2, USP <631>, GLP-ready data logging |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-III-X |
| Price Range | USD 1,400–7,200 (FOB) |
| Temperature Range (°C) | -30 to 1700 (selectable configurations) |
| Heating Rate (°C/min) | 0.1–20 (standard setpoint: 5) |
| Temperature Accuracy (°C) | ±1 |
| Sample Diameter (mm) | 5–10 |
| Sample Length (mm) | ≤50 |
| Measurement Range | 5 mm |
| Resolution | 1 µm (optional 0.1 µm digitization) |
| Atmosphere Options | Air, Vacuum (down to 10⁻¹ mbar), Static/Dynamic Inert (N₂, Ar), Reactive Gas (customizable) |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer | QKTester |
| Model | XRPZ-02 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 10 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 150–200 mm |
| Displacement Range | 0–5 mm (±2.5 mm) |
| Resolution | 0.0001 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 3 kW |
| Dimensions | 800 × 690 × 1700 mm |
| Weight | 29 kg |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | SQW-II-14 |
| Price Range | USD 7,000 – 14,000 |
| Temperature Range | Ambient to 1350 °C (short-term up to 1400 °C) |
| Max Load Capacity | 0–28.29 MPa (0–2000 kgf) |
| Deformation Measurement Range | 0–5 mm (resolution: 0.01 mm) |
| Force Accuracy | ±1 % FS |
| Deformation Accuracy | ±1 % FS |
| Heating Rate | Programmable, two-segment linear ramp |
| Furnace Type | Silicon Carbide (SiC) tube furnace, bore Ø50 mm, power 2.5 kW |
| Loading Speed | 0.8–8 mm/min (manually adjustable) |
| Dimensions (main unit) | 720 × 500 × 1644 mm |
| Weight | 500 kg |
| Power Consumption | <3 kW |
| Ambient Operating Conditions | 0–40 °C, RH <85 %, 220 V ±10 %, 50 Hz, grounded supply, no strong magnetic fields/vibration/corrosive gases |
| Control System | PC-based real-time control with data acquisition, automated report generation, and SQL-compatible database storage |
| Mechanical Drive | Precision ball-screw loading mechanism |
| Sample Geometry | Ø30 × 50 mm truncated cone |
| Compliance | Designed for ASTM E228, ISO 7991, GB/T 4339, and DIN 51045 testing protocols |
| Software Features | GLP-compliant audit trail, user-level access control, experimental sequence scripting, export to CSV/PDF/Excel |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SJY-II-14/17 |
| Price Range | USD 1,400–7,200 (FOB) |
| Max. Temperature | 1400 °C / 1700 °C |
| Heating Rate | 0–10 °C/min |
| Temp. Accuracy | ±1 °C |
| Sample Dimensions | Ø6 mm × 8 mm (cylindrical) |
| Linear Measurement Range | 5 mm |
| Resolution | 0.1 nm |
| Atmosphere Options | Vacuum (≤1.0×10⁻² Pa), Inert Gas (N₂, Ar), or Ambient Air |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 801 / DIL 801L |
| Configuration | Horizontal, single-sample dilatometer |
| Operating Atmosphere | Air, vacuum, or inert gas (N₂, Ar) |
| Temperature Range | −150 °C to 1600 °C (dependent on furnace and sensor option) |
| Force Control | User-adjustable contact force from 0.02 N to 1.00 N |
| Sensor Type | High-stability LVDT with digital signal conditioning |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045-1, USP <671> |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 802/802L |
| Measurement Principle | True Mechanical Differential Expansion Detection |
| Sensor Type | High-Stability LVDT with Digital Amplification |
| Contact Force Range | 0.02–1.00 N (User-Adjustable) |
| Configuration | Convertible Between Differential and Single-Sample Modes |
| Thermal Uniformity | Optimized Horizontal Furnace Design |
| Vibration Resistance | Integrated Mechanical Isolation Architecture |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 803/803L |
| Configuration | Dual-sample horizontal dilatometer with differential capability |
| Sensor Type | High-stability LVDT with digital amplifier |
| Contact Force Range | User-adjustable from 0.02 N to 1.00 N |
| Furnace Compatibility | Interchangeable TA furnace modules |
| Operating Mode | Simultaneous dual-sample or differential (sample vs. inert reference) |
| Compliance | Designed for ASTM E228, ISO 11359-2, and USP <640> thermal expansion testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 805 |
| Temperature Range | −150 to 1300 °C |
| Maximum Heating Rate | ≤4000 °C/s |
| Measurement Resolution | 0.01 µm / 0.05 °C |
| Atmosphere Options | Air, Vacuum, Inert Gases (e.g., Ar, N₂, He) |
| Quench Medium | High-velocity Helium Gas |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 806 |
| Measurement Principle | Non-contact shadow-edge optical imaging |
| Light Source | High-intensity GaN LED with collimated short-wavelength planar illumination |
| Detection | High-resolution CCD sensor with digital edge detection |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | Up to 100 °C/min |
| Cooling Rate | 1400 °C → 50 °C in ≤10 min |
| Furnace Design | Dual-zone planar heating (top + bottom) for minimized axial and radial thermal gradients |
| Sample Area | 30 mm wide field-of-view with position-insensitive measurement |
| Compliance | ASTM E228, ISO 11359-1, USP <632>, GLP/GMP-ready data audit trail (via TRIOS software) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 821 / DIL 822 |
| Measurement Principle | Contact-based linear thermal expansion measurement using optical encoder and linear motor actuation |
| Resolution | 1 nm |
| Configuration | Vertical sample orientation |
| Force Control | Constant low-force contact via linear motor |
| Differential Capability | True differential measurement (DIL 822 only) |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045 |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | DIL 831 |
| Temperature Range | RT to 1700 °C |
| Heating Rate | Up to 50 °C/min |
| Temperature Accuracy | ±0.05 °C |
| Sample Length | 0–25 mm (standard), 12 mm (optimal) |
| Length Resolution | 1 nm |
| Force Range | 0.01–1.00 N |
| Force Resolution | 0.01 N |
| CTE Accuracy | ±0.03 × 10⁻⁶ K⁻¹ |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | DIL 832 |
| Temperature Range | RT to 1700 °C |
| Heating Rate | Up to 50 °C/min |
| Temperature Accuracy | ±0.05 °C |
| Sample Length | 0–25 mm |
| Sample Diameter | ≤6 mm |
| Length Resolution | 1 nm |
| Force Range | 0.01–1.00 N |
| Force Resolution | 0.01 N |
| CTE Accuracy | ±0.01 × 10⁻⁶ K⁻¹ |
| Total Measurement Range | 5000 µm |
| Cooling Time (1000 °C → RT) | 13 min |
| Brand | TA Instruments |
|---|---|
| Origin | Italy |
| Model | OPD 868 |
| Temperature Range | RT – 1650 °C |
| Heating Rate | 0.1 – 100 °C/min (up to 200 °C/sec in transient mode) |
| Temperature Accuracy | ±0.2 °C |
| Sample Length | 1 – 85 mm (mode-dependent) |
| Camera Resolution | 5 MP |
| Multi-sample Capability | Up to 8 ISO-standard specimens simultaneously |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | DIL1000 |
| Temperature Range | Ambient to 600 °C |
| Heating Rate | 10 K/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 20–50 mm |
| Sample Diameter | 3–10 mm |
| Measurement Range | 1 mm |
| Resolution | < 0.1% FS |
| Atmosphere | Air |
| Compliance | ASTM E228, GB/T 4339 |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | DIL0806A |
| Temperature Range | RT–1000 °C |
| Heating Rate | 0–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Sample Dimensions | 10 mm × 50 mm |
| Atmosphere Compatibility | Inert, Oxidizing, Reducing Gases |
| Measurement Resolution (ΔL) | 0.1 µm |
| Sample Holder Material | Fused Quartz / Alumina |
| c-DTA® Function | Optional |
| Compliance Standards | ASTM E831, ASTM D696, ASTM D3386, DIN 51045 |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | HF-PJ-12 |
| Temperature Range | 1200 °C |
| Heating Rate | 5 °C/min (standard), up to 20 °C/min (customizable) |
| Temperature Accuracy | ±1 °C |
| Sample Diameter/Width | 6 mm (cylindrical or square cross-section) |
| Sample Length | 50 mm |
| Expansion Measurement Range | 0–5 mm |
| Resolution | 0.1 µm |
| Atmosphere Options | Vacuum (base pressure −0.1 MPa), Argon, Inert Gas |
| Cooling Rates | 30–200 °C/s (air, gas, liquid nitrogen options) |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PZY-III-1000 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0–30 °C/min (programmable) |
| Displacement Resolution | 0.1 µm |
| Brand | ZHENHUAFENXI |
|---|---|
| Model | XPY |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±1 °C (at 1000 °C) |
| Sample Dimensions | Ø6–8 mm × up to 50 mm L |
| Measurement Range | ±5 mm |
| Resolution | 1 µm |
| Sample Holder Material | Fused Quartz |
| Compliance Standards | GB/T 4100–2015, GB/T 3810.9–2016 |
| Software Platform | Windows 10/7/XP |
| Brand | ZHONGHUAN FURNACE |
|---|---|
| Origin | Tianjin, China |
| Model | TA-16A01 / TA-Z1601 |
| Temperature Range | Ambient to 1600 °C |
| Heating Rate | 0–50 °C/min (adjustable) |
| Atmosphere Options | Air, Vacuum, Inert Gas, Oxidizing Atmosphere |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKDZY-I |
| Temperature Range | 200 °C |
| Heating Rate | 80 °C/min |
| Temperature Accuracy | ±1 °C |
| Stroke/Displacement Range | 1 mm |
| Measurement Resolution | 0.01 mm |
| Atmosphere Control | 12 configurable gas channels |
| Rated Power | 1 kW |
| Rated Voltage | 220 V / 50 Hz |
| Drum Internal Diameter | Φ68 mm |
| Drum Internal Height | 120 mm |
| Steel Ball Diameter | 6 mm |
| Tumbling Speed | 90 rpm |
| Programmable Tumbling Duration | Yes |
| Overall Dimensions (L×W×H) | 700 × 640 × 690 mm |
| Net Weight | 50 kg |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKTKK-700c |
| Temperature Range | 200 °C (max. 700 °C) |
| Max. Heating Rate | 80 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Ø50 mm ±1 mm × 60 mm ±1 mm |
| Measurement Range | 1 mm |
| Resolution | 0.01 mm |
| Atmosphere Control | Air (filtered, pressure-regulated, flow-controlled) |
| Flow Sensor Range | 250 L/h, ±4% FS |
| Pressure Sensor Range | 0–1 MPa, Class ≥1.5 |
| Vibration Frequency | 1 rpm |
| Rated Power | 1.5 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Device Dimensions | 750 × 700 × 1600 mm |
| Weight | 150 kg |