Universal Testing Machine
Filter
Showing 61–90 of 1016 results
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | NLD-BI2 |
| Instrument Type | Electronic Universal Testing Machine |
| Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | 99% Pure Platinum (tips), Copper (holders) |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Pt tip length | 12 mm, bevel angle: 30° ± 2° |
| Electrode Spacing | 4.00 ± 0.01 mm, included angle: 60° ± 5° |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital presettable) |
| 50-droplet duration | 24.5 ± 2 min |
| Droplet Count Range | 1–9999 (digital display & preset) |
| Airflow Velocity | 0.2 m/s (per IEC 60695-11-5) |
| Short-Circuit Current Threshold | 0.50 A ± 10%, hold time: 2.00 s ± 10% |
| Voltage Drop | ≤8% at 1.0 A ± 0.1 A |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Ambient Conditions | 0–40 °C, RH ≤80%, non-corrosive, low-vibration environment |
| Combustion Chamber Volume | >0.5 m³ (approx. 900 × 590 × 1050 mm), black background, illuminance ≤20 lux |
| Exhaust Port Diameter | Ø100 mm |
| Touchscreen | 7-inch color HMI with PLC-based control architecture |
| Compliance | GB/T 4207–2003, IEC 60695-11-5, IEC 60695-11-10 |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NLD-BI4 |
| Instrument Type | Electronic Universal Testing Machine |
| Test Voltage Range | 100–600 V AC (48–60 Hz) |
| Electrode Material | Platinum (99% purity) / Copper electrode holder |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Tip | 12 mm long, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, included angle 60° ± 5° |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 0.1% NH₄Cl, 3.95 ± 0.05 Ω·m |
| Solution B | 1.98 ± 0.05 Ω·m |
| Droplet Height | 35 ± 5 mm (adjustable) |
| Droplet Interval | 30.00 ± 0.01 s (digital display, presettable) |
| 50-droplet duration | 24.5 ± 2 min |
| Droplet Count Range | 1–9999 (digital, presettable) |
| Airflow Velocity | 0.2 m/s (per IEC 60695-11-5) |
| Short-Circuit Current Threshold | 0.50 A ± 10%, hold time 2.00 s ± 10% |
| Voltage Drop Limit | ≤8% at 1.0 A ± 0.1 A |
| Power Supply | 220 V, 0.6 kVA, 50–60 Hz |
| Ambient Conditions | 0–40 °C, RH ≤80%, non-corrosive, low-vibration environment |
| Combustion Chamber Volume | >0.5 m³ (approx. 900 × 590 × 1050 mm), black background, illuminance ≤20 lux |
| Exhaust Port Diameter | Ø100 mm |
| Overall Dimensions (W×D×H) | 1160 × 600 × 1310 mm (incl. leveling feet) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | NLD-C |
| Instrument Category | Electronic Universal Testing Machine |
| Rated Price | USD 1,950 (approx.) |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–5 kV |
| Power Rating | 5 kVA |
| Voltage Accuracy | < ±2% |
| High-Voltage Output Current | > 1 A |
| Short-Circuit Current at ≥250 mA | Voltage Drop < 5% |
| Current Measurement Accuracy | < ±1% |
| Spray Nozzle Distance to Specimen | ≥500 mm |
| Spray Angle Relative to Specimen Axis | 45° |
| Spray Velocity at Specimen Surface | 3 m/s |
| Spray Rate | 0.5 mm/min |
| Standard Spray Cycle | 10 s spray / 20 s pause |
| Specimen Length | ≥150 mm |
| Specimen Preparation | Exposed conductor segment (20 mm), grounding wire wrap (1 mm bare copper, 2–3 turns at 100 mm from cut edge) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-C2 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | AC 0–5 kV |
| Power Rating | 5 kVA |
| Voltage Accuracy | < 2% |
| High-Side Output Current | > 1 A |
| Current Measurement Accuracy | < 1% |
| Spray Velocity at Specimen | 3 m/s |
| Spray Rate | 0.5 mm/min |
| Standard Spray Cycle | 10 s spray / 20 s pause |
| Nozzle-to-Specimen Distance | ≥ 500 mm |
| Nozzle Angle Relative to Specimen Axis | 45° |
| Spray Range | > 1 m |
| Specimen Length | ≥ 150 mm |
| Compliance | GB/T 3048.7–2007 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NLD-C3 |
| Instrument Type | Electronic Universal Testing Machine |
| Input Voltage | AC 220 V |
| Output Voltage Range | 0–5 kV AC |
| Power Rating | 5 kVA |
| Voltage Accuracy | <2% |
| High-Voltage Output Current | >1 A |
| Current Measurement Accuracy | <1% |
| Spray Velocity at Specimen | 3 m/s |
| Spray Rate | 0.5 mm/min |
| Standard Spray Cycle | 10 s spray / 20 s pause |
| Nozzle-to-Specimen Distance | ≥500 mm |
| Nozzle Angle Relative to Specimen Axis | 45° |
| Spray Reach | >1 m |
| Nozzle Height Above Floor | ≥600 mm |
| Specimen Length | >150 mm |
| Electrode Configuration | Bare copper wire (1 mm Ø, 2–3 turns) wound 100 mm from cut end |
| Compliance Standard | GB/T 3048.7–2007 |
| Brand | Guance |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | PMQS-I2 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Power Supply | 220 V / 50 Hz |
| Vertical Travel Range | 0–800 mm |
| Optical Sensor Accuracy | ±1 mm |
| Optical Sensor Range | 10–1000 mm |
| Temperature Probe Range | 0–500 °C (Accuracy: ±0.5% FS) |
| Pressure Sensor Range (Optional) | 0–500 N |
| Sample Cup ID | 100 mm |
| Sample Cup Height | 200 mm |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMTQ-A |
| Instrument Type | Electronic Universal Testing Machine |
| Vacuum Pump Speed | 1.3 m³/h (4.8 L/s) |
| Ultimate Vacuum | 5 × 10² Pa |
| Flow Sensor Range | 0–50 L/min |
| Differential Pressure Sensors | 0–400 Pa & 0–100 Pa |
| Test Chamber Dimensions | 100 mm × 100 mm × 104 mm |
| Specimen Size | 102 mm × 102 mm × 0–100 mm |
| Air Permeability Range | 0–999.9 × 10⁻¹⁰/m² |
| Temperature Sensor Range | −40 °C to +80 °C |
| Chamber Material | 4 mm 304 brushed stainless steel |
| Safety Protections | Over-temperature, over-pressure, over-flow, and overload protection |
| Dimensions (L×W×H) | 800 mm × 630 mm × 700 mm |
| Weight | 85 kg |
| Power Rating | 1 kW |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCSKS-50 |
| Instrument Type | Electronic Universal Testing Machine |
| Standards Compliance | GB/T 19519–2014, GB/T 22079–2008, GB/T 20142–2006 |
| Test Duration | 100 h ± 0.5 h (boiling phase) |
| AC Withstand Voltage | 50 kV / 0.1 A |
| Leakage Current Measurement Range | 40–2000 µA, Class 1 accuracy |
| Boiling Vessel Capacity | 5000 mL spherical reactor |
| Condenser | 2 ×蛇形冷凝管 (19# / 400 mm) |
| Cooling System | CW-3000 chiller |
| Control Interface | 7-inch integrated withstand voltage controller |
| Power Supply | 220 V AC |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | YHT-RC100 |
| Instrument Type | Electronic Universal Testing Machine |
| Control System | Siemens Original PLC |
| Human-Machine Interface | Moxa 10-inch HD Capacitive Touchscreen |
| Compliance | AS4373D, GJB773A, ASD-STAN PRF-6059-502 |
| Test Modes | Dry Arc & Wet Arc (electrolyte-dripped) |
| Voltage Accuracy | ±1% (0.1 V resolution) |
| Current Accuracy | ±1% (0.01 A resolution) |
| Timing Range | 1–99,999,999 s (programmable) |
| Electrode Travel Stroke | 1–10 cm (std. 3.81 ± 0.3 cm) |
| Electrode Reciprocating Speed | 0.5 ± 0.05 cycles per second |
| Electrode Load Mass | 250 ± 25 g |
| Dropping Rate | 100 ± 10 mg/min (8–10 drops/min, via Lead Fluid BV-100 peristaltic pump) |
| Power Supply | AC 220 V ±10%, 50 Hz, 2 kW |
| Generator Output | 20 kVA, 400/230 V, 400 Hz (via integrated frequency converter) |
| Short-Circuit Protection | 30 A breaker |
| Overcurrent Protection | Five 7.5 A breakers |
| Ground Resistance | <1 Ω |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YHT-RC100.3 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Power Input | AC 220 V ±10%, 50 Hz ±0.5 Hz, 2 kW |
| Test Voltage Accuracy | ±1% (0.1 V resolution) |
| Test Current Accuracy | ±1% (0.01 A resolution) |
| Arc Exposure Duration | 1–99,999,999 s (programmable) |
| Dry/Wet Mode Switching | Yes |
| Electrode Travel Range | 1–10 cm (standard 3.81 ±0.3 cm) |
| Electrode Stroke Speed | 0.5 ±0.05 cycles per second (full reciprocation) |
| Electrode Load Mass | 250 ±25 g |
| Dropping Rate (Wet Mode) | 100 ±10 mg/min (8–10 drops/min, via Lead Fluid peristaltic pump) |
| Control System | Siemens original PLC (S7 series) |
| HMI | Kunlun Tongtai 10-inch capacitive touchscreen |
| Compliance Standards | AS4373D, GJB773A, ASD-STAN PRF-6059-502, EN 6059-502 (PrEN) |
| Operating Altitude | ≤1000 m |
| Ambient Temperature | −30 °C to +40 °C |
| Relative Humidity | ≤85 % RH |
| Grounding Resistance | <1 Ω |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Brand | GuanCe |
|---|---|
| Model | YHT-RC100b |
| Type | Electronic Universal Testing Machine |
| Input Power | AC 220 V ±10%, 50 Hz, 2 kW |
| Test Current | 1 A ±0.2 A |
| Voltage Accuracy | ±1% (0.1 V resolution) |
| Current Accuracy | ±1% (0.01 A resolution) |
| Test Duration Range | 1–99,999,999 s |
| Arc Mode | Dry & Wet |
| Dropping Rate | 100 ±10 mg/min (8–10 drops/min) |
| Friction Stroke | 1–10 cm (std. 3.81 ±0.3 cm) |
| Friction Frequency | 0.5 ±0.05 cycles per second |
| Weight Load on Blade | 250 ±25 g |
| PLC Controller | Siemens Original Import |
| HMI | MCGS 10-inch Capacitive Touchscreen |
| Compliance | AS4373D, GJB773A, ASD-STAN, PrEN 6059-502 |
| Dimensions (L×W×H) | 1400 × 830 × 1500 mm |
| Weight | 300 kg |
| Operating Altitude | ≤1000 m |
| Ambient Temp | −30 to +40 °C |
| Relative Humidity | ≤85% RH |
| Grounding Resistance | <1 Ω |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YSRB-300 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Heating Method | Air-bath |
| Test Channels | 3 |
| Temperature Range | Ambient to 300 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 50±3 °C/h or 10±2 °C/12 min |
| Temperature Resolution | 0.1 °C |
| Deformation Resolution | 0.002 mm |
| Specimen Dimensions | 50×50×50 mm or 40×40×20 mm |
| Compression Platen Size | 50×50 mm (×3) |
| Recommended Load Range | 0–1 MPa |
| Heating Chamber Volume | 350×400×400 mm |
| Lever Compression Ratio | 1:32 |
| Loading Configuration | Lever-based dead-weight compression (3 stations), direct dead-weight bending (3 stations) |
| Standard Compliance | GB/T 20672–2006, DIN 53424 |
| Key | Origin: Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Temperature Range | RT–300 °C |
| Heating Rate Options | (12 ± 1) °C/6 min or (5 ± 0.5) °C/6 min |
| Temperature Accuracy | ±1 °C |
| Deflection Measurement Range | 0–10 mm |
| Deflection Resolution | 0.001 mm |
| Heat Transfer Medium | Methyl Silicone Oil |
| Heating Power | 4 kW |
| Cooling Mode | Natural cooling above 150 °C |
| Power Supply | AC 220 V, 20 A, 50 Hz |
| Dimensions (L×W×H) | 540 × 520 × 1360 mm |
| Brand | Hegewald & Peschke |
|---|---|
| Origin | Germany |
| Model | Inspekt Blue |
| Load Capacity | 20 kN or 30 kN |
| Frame Type | Dual-column, benchtop |
| Test Height | 1100 mm |
| Test Width | 420 mm |
| Load Measurement Range | 0.4%–100% of rated capacity |
| Compliance | EN ISO 7500-1, ASTM E4, EN 10002-2 |
| Drive System | Brushless motor, gearless transmission |
| Control Options | Integrated control panel + optional PC-based LABMASTER software |
| Standard Safety Features | Overload protection, automatic calibration, fracture detection, return-to-start |
| Instrument Type | Electromechanical universal testing machine |
| Brand | Hegewald & Peschke |
|---|---|
| Origin | Germany |
| Model | Inspekt Duo |
| Load Capacity | 5 kN / 10 kN |
| Frame Type | Dual-column, benchtop |
| Test Space Height | 1025 mm or 1325 mm |
| Test Space Width | 420 mm |
| Load Measurement Range | 0.4–100% of rated load |
| Compliance | EN 10002-2, ASTM E4, DIN EN ISO 7500-1 |
| Noise Level | ≤ 65 dB(A) |
| Drive System | Brushless motor, gearless transmission |
| Control Interface | Touch-enabled control panel and PC-based operation |
| Standard Functions | Overload protection, automatic calibration, fracture detection, auto-return |
| Software (optional) | LABMASTER |
| Brand | Hegewald & Peschke |
|---|---|
| Origin | Germany |
| Model | Inspekt Solo S / M / L |
| Max Load Capacity | 2.5 kN |
| Frame Type | Single-column |
| Crosshead Travel | 475 mm / 1075 mm / 1375 mm |
| Load Measurement Range | 0.2–100% of rated capacity (Class 1 accuracy, optional Class 0.5) |
| Load Cell Technology | Strain-gauge-based |
| Control Interface | USB 2.0 or LAN |
| Software | LABMASTER |
| Overload Protection | Yes |
| Automatic Sample Break Detection | Yes |
| Auto-return Function | Yes |
| Calibration | Automated |
| Weight | 48–60 kg (S–L variants) |
| Compliance Standards | ASTM E4, ASTM D638, ISO 527, ISO 178, DIN 53455, JIS K7113 |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-0580TBHBTG |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 5 N to 5000 N (selectable) |
| Force Accuracy Class | 0.5 |
| Effective Test Width | 120 mm |
| Effective Vertical Travel | 800 mm |
| Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Strain Measurement Accuracy | ±0.5% of indicated value |
| Force Resolution | ±500,000 counts at full scale (no range switching) |
| Stress Control Rate Range | 0.005–6 %FS/S |
| Strain Control Rate Range | 0.002–6 %FS/S |
| Safety Features | Electronic limit protection, overload auto-stop (>110% FS), real-time system diagnostics |
| Power Supply | 220 V AC, 750 W |
| Dimensions (W×D×H) | 470 × 400 × 1510 mm |
| Weight | 100 kg |
| Compliance | GB/T 16491–2008, ISO 527, ASTM D638/D790/D3763, JIS K7113, EN 10002-1 |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-0230 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Max Load Capacity | ≤2000 N (configurable) |
| Load Cell Accuracy | 0.01% FS |
| Measurement Accuracy | ±0.5% |
| Control Mode | Full CNC or PC-controlled with thermal printer interface |
| Valid Test Width | 150 mm |
| Effective Stroke | 300 mm (extendable) |
| Test Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% |
| Stroke Accuracy | ±0.5% |
| Displacement Measurement Accuracy | ±0.5% |
| Safety Features | Electronic stroke limit protection, emergency stop button |
| Unit Weight | ~45 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HY-0230 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 2000 N |
| Accuracy Class | 0.5 |
| Effective Test Width | 120 mm |
| Vertical Test Space | 300 mm |
| Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement Accuracy | ±0.5% of reading |
| Strain Measurement Accuracy | ±0.5% of reading |
| Control Modes | Force, Displacement, Strain, and Constant-Rate |
| Safety Features | Electronic Limit Protection, Overload Protection (110% FS), Auto-Return, Programmable Stop Conditions |
| Power Supply | 220 V AC, 200 W |
| Dimensions (W×D×H) | 430 × 315 × 855 mm |
| Weight | 40 kg |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-0230BM |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 1N–2000N (multi-range selectable) |
| Accuracy Class | ≤0.5% |
| Effective Test Width | 120 mm |
| Effective Stroke | 300 mm |
| Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Force Resolution | ±500,000 counts (full-scale, no range switching) |
| Displacement & Strain Measurement Accuracy | ±0.5% of indicated value |
| Stress/Strain Control Rate Range | 0.002–6% FS/S |
| Load Cell | Imported bidirectional precision load cell (USA) |
| Drive System | Panasonic servo motor & driver (Japan) |
| Lead Screw | Preloaded high-precision ball screw (imported) |
| Frame | Rigid single-column structural design |
| Safety Features | Electronic travel limit, overload protection (110% FS), auto-diagnostic system |
| Power Supply | 220 V AC, 200 W |
| Dimensions (W×D×H) | 430 × 315 × 855 mm |
| Weight | 40 kg |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HY-0230L |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 1N–2000N (multi-range selectable) |
| Accuracy Class | ≤0.5% of full scale |
| Effective Test Width | 120 mm |
| Effective Stroke | 300 mm |
| Speed Range | 0.001–300 mm/min (adjustable) |
| Speed Accuracy | ±0.5% of indicated value |
| Force Resolution | ±500,000 counts (full-scale, no range switching) |
| Displacement & Strain Measurement Accuracy | ±0.5% of indicated value |
| Stress/Strain Control Rate Range | 0.002–6% FS/S |
| Constant-Load/Displacement/Deformation Control Range | 0.5–100% FS |
| Protection Features | Electronic limit switch, overload protection (>110% FS), auto-diagnostic system |
| Power Supply | 220 V AC, single-phase, 200 W |
| Dimensions (W×D×H) | 430 × 315 × 855 mm |
| Weight | 40 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY-0230rt |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 1 N to 2000 N (interchangeable load cells) |
| Force Accuracy | ≤ ±0.5% of reading |
| Force Resolution | ±500,000 counts (full-scale, no range switching) |
| Effective Test Width | 120 mm |
| Vertical Test Space | 300 mm |
| Speed Range | 0.001–300 mm/min (adjustable) |
| Speed Accuracy | ±0.5% of set value |
| Displacement Accuracy | ±0.5% of reading |
| Strain Control Range | 0.002–6% FS/s |
| Stress Control Range | 0.005–6% FS/s |
| Safety Features | Electronic travel limit, overload protection (110% FS), auto-return, programmable stop conditions (load/strain/time), real-time system diagnostics |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY-0230UIK |
| Instrument Type | Electronic Universal Testing Machine |
| Maximum Load Capacity | 2000 N (configurable) |
| Load Cell Accuracy | 0.01% |
| Measurement Accuracy | < ±0.5% |
| Control Mode | Full CNC or PC-controlled with standard report printing |
| Valid Test Width | 150 mm |
| Effective Stroke | 300 mm (extendable) |
| Test Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% |
| Stroke Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Safety Features | Electronic stroke limit protection, emergency stop button |
| Unit Weight | ~45 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromechanical Universal Testing Machine |
| Model | HY-0230VB |
| Load Capacity Options | 1 N to 2000 N (interchangeable load cells) |
| Force Accuracy | ≤0.5% of reading |
| Force Resolution | ±500,000 counts (full-scale, no range switching) |
| Effective Test Width | 120 mm |
| Effective Vertical Travel | 300 mm |
| Speed Range | 0.001–300 mm/min (adjustable, ±0.5% speed accuracy) |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Stress/Strain Control Rate Range | 0.002–6% FS/s |
| Constant-Load/Displacement/Deformation Control Range | 0.5–100% FS |
| Power Supply | 220 V AC, 200 W |
| Net Weight | 40 kg |
| Dimensions (W×D×H) | 430 × 315 × 855 mm |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (PRC) |
| Model | HY-0230WRV |
| Instrument Type | Electronic Universal Testing Machine |
| Load Capacity | ≤2000 N |
| Load Cell Accuracy | 0.01% FS |
| Measuring Accuracy | < ±0.5% |
| Test Speed Range | 0.001–300 mm/min |
| Stroke | ≥300 mm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 900 × 350 × 450 mm |
| Weight | ≈95 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-0230WX |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 1 N to 2000 N (multi-sensor configurable) |
| Force Accuracy | ≤0.5% of reading |
| Effective Test Width | 120 mm |
| Vertical Test Space | 300 mm |
| Speed Range | 0.001–300 mm/min (adjustable) |
| Speed Accuracy | ±0.5% of set value |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Control Modes | Stress, strain, and displacement control |
| Power Supply | 220 V AC, single-phase, 200 W |
| Net Weight | 40 kg |
| Dimensions (W×D×H) | 430 × 315 × 855 mm |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HY-0350P |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 1 N to 3000 N (interchangeable load cells) |
| Force Accuracy | ≤ 0.5% of reading |
| Effective Test Width | 120 mm |
| Vertical Test Space | 500 mm |
| Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Control Modes | Stress, strain, and displacement control |
| Power Supply | 220 V AC, single-phase, 400 W |
| Net Weight | 75 kg |
| Dimensions (W×D×H) | 440 × 380 × 1100 mm |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-035022 |
| Instrument Type | Electronic Universal Testing Machine |
| Load Capacity | 3000 N |
| Accuracy Class | 0.5 |
| Effective Test Width | 120 mm |
| Effective Test Height | 500 mm |
| Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Force Resolution | ±500000 counts (full-scale, no range switching) |
| Force Measurement Range | 0.1–99.99% of full scale |
| Displacement Accuracy | ±0.5% of indicated value |
| Strain Measurement Accuracy | ±0.5% of indicated value |
| Stress Control Rate Range | 0.005–6% FS/s |
| Strain Control Rate Range | 0.002–6% FS/s |
| Constant Load/Displacement/Strain Range | 0.5–99.99% FS |
| Protection Features | Electronic limit switch, overload protection (10% over full scale), auto-diagnostic system |
| Power Supply | 220 V AC, single-phase, 400 W |
| Host Dimensions | 440 × 380 × 1100 mm |
| Net Weight | 75 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HY-035055 |
| Max Load Capacity | 3000 N |
| Load Accuracy Class | 0.5 |
| Effective Test Width | 120 mm |
| Effective Test Height | 500 mm |
| Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement Accuracy | ±0.5% of reading |
| Strain Measurement Accuracy | ±0.5% of reading |
| Force Resolution | ±500,000 counts (full-scale, no range switching) |
| Power Supply | 220 V AC, 400 W |
| Net Weight | 75 kg |
| Dimensions (W×D×H) | 440 × 380 × 1100 mm |
| Compliance | ISO 7500-1, ASTM E4, ASTM E8/E21, GB/T 228.1 |
| Key | Brand: Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromechanical Universal Testing Machine |
| Model | HY-0350JH |
| Load Capacity Options | 1 N to 3000 N (interchangeable load cells) |
| Force Accuracy | ≤ ±0.5% of reading |
| Force Resolution | ±500,000 counts (full-scale, no range switching) |
| Crosshead Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Effective Test Width | 120 mm |
| Vertical Test Space | 500 mm |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Control Modes | Stress, Strain, and Displacement Rate Control |
| Power Supply | 220 V AC, 400 W |
| Net Weight | 75 kg |
| Dimensions (W×D×H) | 440 × 380 × 1100 mm |