- All
- Favorite
- Popular
- Most rated
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 5500 |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Spectral Range | 4,000 to 650 cm⁻¹ |
| Dimensions (W × D × H) | 20 cm × 20 cm × 11 cm |
| Weight | 3.6 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sampling Modules | Fixed Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath |
| Software Platform | MicroLab, MicroLab Expert, MicroLab Quant, MicroLab Pharma (optional) |
| Library Support | Pre-validated application-specific spectral libraries |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin Category | Imported Instrument |
| Model | TRS100 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 50–2300 cm⁻¹ |
| Laser Wavelength | 830 nm |
| Laser Power | 650 mW |
| Calibration Standards | NIST SRM 706a (polystyrene), NIST SRM 2246 (green glass), Mercury-Argon Light Source Calibration Tray |
| Detection Limit | 0.1% w/w (API in solid dosage forms) |
| Regulatory Compliance | US FDA 21 CFR Part 11, EU Annex 11, USP <858>, USP <1858>, EP <2.2.48> |
| Sustainability Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 280Z GFAA |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-Beam |
| Background Correction | Zeeman Effect |
| Atomizer | GTA 120 Zeeman Graphite Furnace |
| Light Source Configuration | Up to 8 Fixed-Lamp Positions |
| Detector | Photomultiplier Tube (PMT) |
| Calibration Method | Polynomial Interpolation |
| Software Platform | Windows-Based Worksheet Interface |
| Optional Hydride Generation Compatibility | VGA Adapter Available |
| Temperature Control Architecture | Isothermal Zone Graphite Furnace Design |
| Lamp Technology | UltrAA Hollow Cathode Lamps (AC-Modulated) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Excitation & Emission Wavelength Range | 200–900 nm |
| Wavelength Accuracy | ±1.5 nm |
| Spectral Bandwidth (Excitation/Emission) | 1.5, 2.5, 5, 10, 20 nm (including 10 nm round) |
| Light Source | Pulsed Xenon Lamp (80 Hz) |
| Detector | High-Sensitivity PMT |
| Scan Speed | Up to 24,000 nm/min |
| Data Acquisition Interval | As fast as 12.5 ms per point |
| Dimensions (W × D × H) | 608 × 644 × 271 mm |
| Weight | 30 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Software | Cary WinFLR |
| Warranty | 10-year lamp lifetime guarantee (applies to new systems purchased from Agilent or authorized partners) |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Resolve |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| IP Rating | IP67 |
| Laser Wavelength | 830 nm |
| Maximum Laser Power | 475 mW |
| Dimensions (W × H × D) | 155 mm × 290 mm × 73 mm |
| Weight | 2.2 kg |
| Power Supply | Rechargeable Lithium-ion Battery with AC Adapter |
| Connectivity | USB 2.0, Optional Wi-Fi Module |
| Operating Modes | Through-Packaging SORS, Surface Raman, Glass Bottle Mode |
| Analysis Time (Typical) | ~60 s for Solids, Powders, Liquids, and Mixtures |
| Supported Languages | English, Korean, German, Chinese, French, Portuguese, Japanese, Spanish, Czech |
| Onboard Library Tiers | Standard, Toxic & Hazardous Materials, Comprehensive |
| Library Update Frequency | Biannual |
| Software Platform | Agilent Command Instrument Group Management Software |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 240Z AA |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | ≤0.2 nm |
| Repeatability (RSD) | <2% |
| Detection Limit (Cd) | ≤0.006 µg/L |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Cobalt Insight100 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Regulatory Compliance | ECAC Standard 3 (Type A & B) |
| False Alarm Rate | ~2.5% across container types |
| Scan Time | ≤5 seconds per sample |
| Upgrade Path | Field-upgradable to Insight100M |
| Software Platform | Cobalt Overview Management Server |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 4000 |
| Optical Design | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–900 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 0.01–5.00 nm (variable) |
| Photometric Range | 0–8.0 Abs |
| Light Sources | Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Maximum Scan Speed | 2000 nm/min |
| Sample Compartment Z-Height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | RapID |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Discontinued Date | 1 August 2025 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 7000 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 10 Abs |
| Max Scan Speed | UV-Vis 2000 nm/min, NIR 8000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 240FS AA |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Sensitivity | Mark 7 Atomization System — Cu 5 mg/L typically yields >0.9 Abs |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Cary 630 |
| Instrument Type | Benchtop Fourier Transform Infrared Spectrometer |
| Wavenumber Range | KBr beam splitter: 7,000–350 cm⁻¹ |
| ZnSe beam splitter | 5,100–600 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Dimensions (W × D × H) | 14 × 26 × 16 cm |
| Weight | 3.5 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sample Compatibility | Solids, powders, pellets, liquids, gels, pastes, gases |
| Sampling Modules | Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath, Ge ATR, Mirror Reflection (10° and 45°), Transmission, Diffuse Reflectance, Gas Cell |
| Software | Agilent MicroLab, MicroLab Expert, MicroLab Pharma (optional, 21 CFR Part 11 & EU Annex 11 compliant) |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Cobalt Insight200M |
| Instrument Type | Grating-Based Raman Spectrometer |
| Certification | ECAC Type A & Type B Certified LEDs |
| Laser Class | Class 1 |
| Power Supply | 90–264 VAC, 50–60 Hz |
| Power Consumption | 200 W continuous |
| Dimensions (W × D × H) | 562 mm × 417 mm × 536 mm |
| Weight | 25 kg |
| Sample Throughput Time | ≤6 seconds per container |
| False Alarm Rate | <2.5% (validated in operational deployment) |
| Container Compatibility | Aerosols, cardboard/paper, transparent/colored/frosted/opaque glass, aluminum beverage cans, foil pouches, food tins, Tetra Pak®, sorbent tubes |
| Max Container Size | 38 cm height × 20 cm diameter |
| Volume Range | 10 mL to 3 L |
| Regulatory Compliance | CE-marked, UK Department for Transport approved |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 5000 |
| Optical Design | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Photometric Range | ±8.0 Abs |
| Scan Speed | UV-Vis up to 2000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Purge | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 5800 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | S (180.669 nm) < 5 µg/L |
| Precision (RSD) | ≤1.0% |
| Short-Term Stability (RSD) | ≤0.5% |
| Wavelength Range | 167–785 nm |
| Optical Resolution | ≤0.0065 nm (at As 188.980 nm) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5900 ICP-OES |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | S (180.669 nm) < 5 µg/L |
| Repeatability | ≤1.0% RSD |
| Short-Term Stability | RSD ≤0.5% |
| Wavelength Range | 167–785 nm |
| Optical Resolution | ≤0.0065 nm (at As 188.980 nm) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 280FS AA |
| Instrument Type | Flame AAS |
| Monochromator Type | Fixed-grating with high-resolution etched grating |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Lamp Capacity | 8-lamp turret with automatic selection |
| Atomization System | Mark 7 Flame Burner Assembly |
| Sensitivity | >0.9 Abs for 5 mg/L Cu |
| Sample Volume per Analysis | 10 mL |
| Multi-element Throughput | Up to 10 elements per sample in <2 minutes |
| Calibration Automation | SIPS 10/20 Integrated Sample Introduction and Dilution System |
| Software Platform | SpectrAA Method Development Suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 4500 |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Spectral Range | 4000–650 cm⁻¹ |
| Dimensions (W×H×D) | 29 cm × 19 cm × 22 cm |
| Weight | 6.8 kg |
| Power Supply | Internal rechargeable battery (up to 4 h operation) / 100–240 VAC, 50/60 Hz |
| Software | MicroLab FTIR and MicroLab Expert |
| Sample Types | Solids, pellets, liquids, pastes, powders, gels |
| Sampling Interfaces (Fixed Options) | Diamond ATR (1×, 3×, or 5× reflection), Multireflection ZnSe ATR, TumblIR, DialPath |
| Library Support | Application-specific spectral libraries pre-installed |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 60 UV-Vis |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.5 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AA DUO |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator Type | Custom High-Resolution Echelle Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Zeeman Effect |
| Linear Dynamic Range | Sub-ppt to Percent-Level Concentrations |
| Automation | Fully Integrated Dual-Atomizer Control via Agilent Workstation Software |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 350–2000 cm⁻¹ |
| Spectral Resolution | 12–20 cm⁻¹ |
| Minimum Wavenumber | 350 cm⁻¹ |
| Spectral Repeatability | < ±0.2 cm⁻¹ |
| Laser Wavelength | 830 nm |
| Laser Power | 450 mW (Class 3B) |
| Battery Life | Up to 4 hours |
| Weight | 1.62 kg |
| Dimensions (W × D × H) | 127 mm × 257 mm × 60 mm |
| Regulatory Compliance | USP <1120>, <1058>, <858>, <1225>, <1858>, EP 2.2.48, 21 CFR Part 11, EU Annex 11 |
| Software Features | Guided method development & validation, audit trail, electronic signatures, LIMS integration, QR/barcode scanning, Wi-Fi & Ethernet connectivity |
| Accessories Included | Dual rechargeable Li-ion batteries, bottle adapter head, NIST-traceable system verification test slide, wrist strap, glass vial stand, shoulder strap, five sample vials |
| Language Support | English, French, Portuguese, Chinese, German, Italian, Korean, Spanish, Japanese |
| Sustainability Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 4300 |
| Instrument Type | Handheld |
| Instrument Class | Fourier Transform Infrared (FTIR) |
| Spectral Range | 5,200–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ (standard) |
| Detector | DTGS with Diamond ATR option |
| Sampling Modes | Diamond-ATR, Ge-ATR, Specular Reflectance, Diffuse Reflectance, Grazing Angle, Retro-reflector |
| Dimensions | 35 cm (H) × 19 cm (D) |
| Weight | 2.2 kg |
| Power Supply | Hot-swappable Li-ion battery (4 h typical runtime) / 100–240 VAC, 50/60 Hz |
| Software Platform | MicroLab Mobile, MicroLab Expert, optional MicroLab Pharma (21 CFR Part 11 & EU Annex 11 compliant) |
| Sample Types | Solids, Pellets, Liquids, Pastes, Powders, Gels |
| Library Options | Preloaded application-specific spectral libraries (ATR, geological minerals), customizable library creation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 6000i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–1800 nm (UV-Vis-NIR) |
| Automation Level | Motorized wavelength scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 8.0 Abs |
| Scan Speed | UV-Vis: 2000 nm/min |
| NIR | 8000 nm/min |
| Sample Compartment Z-height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Purge Capability | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 3500 |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.1 – 5.0 nm (UV-Vis) |
Show next