- All
- Favorite
- Popular
- Most rated
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Vacuum Pump |
| Model | TwisTorr 704 FS Turbo-Molecular Pump |
| Pump Type | Oil-Free Turbo-Molecular Pump |
| Pumping Speed | 700 L/s (for N₂) |
| Ultimate Pressure | <1 × 10⁻¹⁰ mbar |
| Weight | 20.6 kg |
| Flange | DN 160 CF |
| Noise Level | 43 dB(A) |
| Bearing System | Active Magnetic Suspension (AFS) |
| Radiation & Magnetic Field Resistance | Yes |
| Control Interface | Vacuum Link wireless app, remote operation up to 100 m |
| Compliance | Designed for UHV/GHV systems compliant with ISO 2861, ASTM F2435, and compatible with GLP/GMP audit requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Bravo NGS |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Precision |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Models | BioCel 1800, BioCel 1200, BioCel 900 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | VHS-400 |
| Pumping Speed | Up to 4500 L/s |
| Weight | 81 kg (180 lbs) |
| Heater Power | 4400 W |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | MS-101 Rotary Vane Pump |
| Instrument Type | Single-Stage Oil-Lubricated Rotary Vane Vacuum Pump |
| Ultimate Pressure | 8 × 10⁻² mbar (6 × 10⁻² torr) |
| Cooling Method | Air-Cooled |
| Blade Material | Carbon-Fiber-Reinforced Composite |
| Rotor Material | Precision-Machined Steel |
| Integrated Features | Anti-Backstreaming Valve, Gas Ballast (Vapor Handling) Valve, Oil Mist Separator with Floating Oil Recovery Valve |
| Design | Compact, Low-Vibration, Maintenance-Optimized Architecture |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Vacuum Pump |
| Model | TwisTorr 84 FS Turbo-Molecular Pump |
| Pumping Speed | 80 L/s for N₂ |
| Ultimate Pressure | <5 × 10⁻¹⁰ mbar |
| Weight | 2.05 kg |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BenchCel Workstation |
| Pricing | Upon Request |
| Deck Capacity | Up to 60 standard SBS microplates per plate rack |
| Configurable Rack Count | 2, 4, or 6 plate racks |
| Transfer Time per Plate | ≤8 seconds |
| Compatible Peripheral Modules | Agilent PlateLoc thermal sealer, barcode labeler, centrifuge |
| Software Platform | VWorks Automation Control Software |
| Footprint | Compact benchtop design compliant with standard laboratory cabinetry dimensions |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Vacuum Pump |
| Model | TwisTorr 74 FS Turbo Molecular Pump |
| Pumping Speed | 70 L/s (for N₂) |
| Ultimate Pressure | <5 × 10⁻¹⁰ mbar |
| Weight | 2.05 kg |
| Noise Level | 41 dB(A) |
| Bearing System | Active Magnetic Suspension (Contact-Free) |
| Pre-stage Tolerance | Up to 10 mbar |
| Compression Ratio (H₂) | >1 × 10⁸ |
| Hydrocarbon-Free Operation | Yes |
| Remote Control Range | Up to 100 m via RS-485 or Ethernet |
| Wireless Interface | Vacuum Link mobile application (Bluetooth® + Wi-Fi enabled) |
| Radiation & Magnetic Field Resistance | Fully compliant with IEC 61000-4-8 (magnetic immunity) and IEC 61000-4-3 (RF immunity) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | MS120 Rotary Vane Pump |
| Instrument Type | Rotary Vane Vacuum Pump |
| External Dimensions | 516 mm × 539 mm × 750 mm (W × H × D) |
| Weight | 100 kg |
| Ultimate Total Pressure (with Gas Ballast) | ≤ 0.2 mbar |
| Ultimate Partial Pressure | ≤ 0.07 mbar |
| Pumping Speed | Not specified in source data |
| Noise Level | 60 ± 1 dB(A) |
| Oil Capacity (Min/Max) | 1.8 L |
| Water Vapor Tolerance | 15 mbar |
| Water Vapor Handling Capacity | 1000 g/h |
| Inlet Connection | 40 KF DN |
| Exhaust Connection | 25 KF DN |
| Input Voltage | 200–240 V, 50/60 Hz |
| Continuous Duty Cycle | Up to 1 year without oil maintenance |
| Drive | Variable-Frequency Motor |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | VSpin |
| Instrument Type | Benchtop Centrifuge |
| Form Factor | Robotic-Accessible, Compact Footprint |
| Cycle Time | ≤3 seconds (load + spin + unload) |
| Compatibility | Standard SBS-format microplates (96-well, 384-well, 1536-well), PCR plates, deep-well plates, skirted/unskirted formats |
| Drive System | Brushless DC motor with closed-loop speed control |
| Vibration Isolation | Integrated passive damping mounts |
| Automation Interface | RS-232, Ethernet (TCP/IP), and optional TTL I/O for robotic handshake protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | AssayMAP Bravo |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MS-631 |
| Pump Type | Rotary Vane Pump |
| Lubrication Type | Oil-Lubricated |
| Ultimate Pressure | 8 × 10⁻² mbar (6 × 10⁻² torr) |
| Cooling Method | Air-Cooled |
| Rotor Material | Steel |
| Vane Material | Carbon-Fiber-Reinforced Composite |
| Integrated Features | Gas Ballast Valve, Oil Mist Separator, Floating Oil Recovery Valve, Frameless Mounting Option |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MS40+ |
| Instrument Type | Rotary Vane Vacuum Pump |
| External Dimensions | 298 mm (W) × 419 mm (L) × 266 mm (H) |
| Weight | 33 kg |
| Ultimate Pressure | < 5 × 10⁻² mbar |
| Drive | Variable-Frequency Motor |
| Compatible Pump Oils | AVF Gold and AVF Platinum |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | VacIon Plus 20 Pump |
| Pumping Speed | 20 L/s |
| Ultimate Vacuum | < 1 × 10⁻¹¹ mbar |
| Weight | 7 kg |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | Bravo |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Oil-Free Vacuum Pump |
| Pumping Speed | 15 m³/h (250 L/min) at 60 Hz |
| Ultimate Pressure | 1.3 × 10⁻² mbar |
| Noise Level | 68 dB(A) |
| Inlet Connection | NW25 |
| Exhaust Connection | NW16 |
| Operating Temperature Range | 5–40 °C |
| Weight (Pump Only) | 26.4 kg (57 lbs) |
| Transport Weight | 34.2 kg (75 lbs) |
| Dimensions (W × H) | 274 mm × 356 mm (10.8 in × 14 in) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Italy |
| Manufacturer | Agilent Technologies |
| Product Type | Oil-Free Vacuum Pump |
| Pumping Speed | 125 L/s |
| Ultimate Pressure | ≤ 5 × 10⁻² mbar |
| Weight | 43 kg |
| Motor Power | 480 W |
| Flange Type | ConFlat (Non-Rotating Inlet) |
| Operating Temperature (Bakeout) | > 400 °C |
| Magnetic Field | Low-Field Design |
| Leak Current | Low |
| Compliance | Designed for UHV/XHV compatibility, GLP/GMP-aligned vacuum integrity protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | VacIon 2 L/s Ion Pump |
| Instrument Type | Other Vacuum Pump |
| Product Type | Oil-Free Vacuum Pump |
| Ultimate Vacuum | < 1 × 10⁻¹¹ mbar |
| Weight | 0.3 kg (0.66 lbs) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Vacuum Pump |
| Model | TwisTorr 305 FS |
| Pump Type | Turbo Molecular Pump |
| Pumping Speed (N₂) | 300 L/s |
| Ultimate Pressure (N₂) | <1 × 10⁻¹⁰ mbar |
| Ultimate Pressure (Torr) | <1 × 10⁻¹⁰ Torr |
| Weight | 5.84 kg |
| Noise Level | 41 dB(A) |
| Remote Control Range | Up to 100 m |
| Bearing Type | Maintenance-Free Magnetic Bearings |
| Radiation & Magnetic Field Resistance | Yes |
| Electromagnetic Emission | Low, Non-Interfering |
| Hydrocarbon-Free Operation | Yes |
| Integrated Vacuum Gauge Interface | Yes |
| Wireless Control | Bluetooth-enabled via Vacuum Link App |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DDR |
| Pricing | Available upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Origin | Imported |
| Model | MicroFill |
| Pricing | Upon Request |
| Dispensing Volume Range | 5 µL to 6,000 µL |
| Compatible Plate Formats | 24-, 96-, and 384-well plates (low-, standard-, and deep-well) |
| Dispensing Accuracy | ±1 µL at 5 µL and 20 µL |
| Dispensing Precision (CV) | ≤10% at 5 µL, ≤5% at 20 µL, ≤2% at ≥100 µL |
| Fluid Path Sterilization | Autoclavable (121 °C, 20 min) |
| Number of Reagents | Single-channel |
| Control Interface | Integrated front-panel software with multilingual support |
| Programmable Methods | Up to 75 stored protocols |
| Liquid Delivery Mechanism | Microprocessor-controlled syringe pump |
| Reservoir Type | Disposable or reusable low-volume reservoir |
| Footprint | Benchtop, compatible with biosafety cabinets |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AX-65 |
| Pump Type | Oil-Based High-Vacuum Diffusion Pump |
| Pumping Speed — He/H₂ | 90 L/s |
| Pumping Speed — Air | 65 L/s |
| Weight | 8 lbs (3.63 kg) |
| Cooling Method | Air-Cooled |
| Prevacuum Requirement | ≥ 0.25 m³/h (0.15 cfm) |
| Ultimate Pressure | ≤ 6.5 × 10⁻⁸ mbar |
| Maximum Forepressure (Loaded) | 0.78 mbar |
| Oil Capacity | 30 mL |
| Warm-up Time | 7 min |
| Cool-down Time | 10 min |
| Oil Return Rate | 2 × 10⁻⁴ mg/cm²/min |
| Electrical Input | Single-phase, 50/60 Hz, 90/115/165/220 V |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Seal Piercer |
| Pricing | Available Upon Request |
Show next