| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity III Analytical-Scale LC |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.05–5 mL/min (with G7112B pump), 0.2–10 mL/min (with G7110B/G7111A/G7111B pumps) |
| Maximum Operating Pressure | 600 bar |
| Column ID Reader | Optional |
| Solvent Reservoir Capacity | Up to 15 channels (with optional Solvent Selection Valve) |
| Fraction Collection Capacity | Up to 384 fractions (4 × 96-well microplates) or 216 tubes (glass, 4 tube OD sizes) |
| Injection Volume Range | 0.1–100 µL (standard), up to 1800 µL (with Multi-Draw Kit) |
| Column Temperature Zones | 2 (with G7116A/B), 1 (with Vial Sampler + Integrated Column Compartment) |
| Detector Compatibility | UV/Vis, RI, FL, ELSD, Single-Quadrupole LC/MSD |
| Software Platform | Agilent OpenLab CDS ChemStation |
| Delay Volume Sensor | Integrated, auto-calibrating |
| System Dimensions (W × D) | 980 × 468 mm |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity II Preparative |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–200 mL/min |
| Flow Accuracy | ≤0.3% RSD |
| Flow Precision | ≤0.3% RSD |
| Maximum Operating Pressure | 600 bar |
| Wavelength Resolution | 0.1 nm |
| Baseline Noise | 2.5 µAU |
| Data Acquisition Rate | 120 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1220 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.2–10 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity II Automated Preparative LC/MSD |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 20–600 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Analytical LC System |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | up to 5 mL/min (with G7120A and G7104A pumps) |
| Maximum Operating Pressure | 1300 bar |
| Column ID Reader | Optional |
| Solvent Reservoir Capacity | 4 standard, up to 15 with optional Solvent Selection Valve |
| Injection Volume Range | 0.1–100 µL (standard), 0.1–1500 µL (with Multi-Draw Kit) |
| Fraction Capacity | up to 384 fractions (4 × 96-well plates or 216 glass tubes) |
| Delay Volume Sensor | Integrated, auto-calibrating |
| Temperature Zones | 2 (with G7116B column compartment), 1 (with vial sampler-integrated column oven) |
| Pump Type | Binary Gradient Pump |
| System Dimensions (W × D) | 980 × 468 mm |
| Power Supply | 100–240 VAC |
| Software Platform | Agilent OpenLab CDS ChemStation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative LC/MSD |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–50 mL/min |
| Maximum Operating Pressure | 20–420 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Manual Preparative |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–50 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1290 Infinity II Automated Preparative |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 20–600 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity II Analytical-Scale Purification System |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | Up to 5 mL/min (with G7120A Binary Pump and G7104A Autosampler) |
| Maximum Operating Pressure | 1300 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 1260 Infinity III Bio-Inert Analytical LC System |
| Maximum Operating Pressure | up to 600 bar |
| Flow Path Material | Metal-Free (Titanium, PEEK, Sapphire, Ceramic) |
| pH Range | 1–13 (short-term exposure to pH 14) |
| Salt Tolerance | up to 2 mol/L NaCl |
| Residual Carryover | <9 ppm |
| Fraction Collection Capacity | up to 384 wells (4 × 96-well plates) or 216 tubes (4 tube diameters) |
| Detection Options | Bio-inert UV and Fluorescence Flow Cells |
| Solvent Mixing | Quaternary Gradient Mixing with Active Seal Wash |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50 mL/min |
| Flow Accuracy | ≤0.3% RSD |
| Flow Precision | ≤0.3% RSD |
| Maximum Pressure | 420 bar |
| Wavelength Range | 190–700 nm (0.1 nm resolution) |
| Baseline Noise | 2.5 µAU at 254 nm, 1 s time constant |
| Data Acquisition Rate | 120 Hz |
| Injection Volume Range | 0.1–5000 µL |
| Fraction Capacity | Up to 648 tubes (with optional fraction collector upgrade) |
| System Dead Volume | Minimized via integrated delay sensor calibration |
| Solvent Channels | 2 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W × D × H) | 941 × 462 × 640 mm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.05–5 mL/min (with G7112B Pump) |
| Maximum Operating Pressure | 600 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Analytical Bio-LC Purification System |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Operating Pressure | 1300 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity II Preparative LC/MSD |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 20–600 bar |