- All
- Favorite
- Popular
- Most rated
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Hybrid Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Bio-Inert Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Operating Pressure | Up to 600 bar |
| Carryover | <9 ppm |
| Temperature Control Range (Optional) | 4–40 °C |
| Flow Path Materials | Ceramic needle, PEEK needle seat, stainless-steel-coated PEEK capillary |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Sample Bottle Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 1300 bar |
| Injection Volume Range | Up to 1500 µL |
| Needle Wash Port | External surface rinse capability |
| Optional Integrated Column Oven | Temperature range 5–80 °C above ambient, accommodates two columns up to 30 cm length |
| Optional Integrated Sample Thermostat | Temperature control from 4–40 °C |
| Internal System Volume | Minimized design with bypass mode available |
| Overlapped Run/Injection Cycle | Enabled for throughput optimization |
| Programmable Sequence Logic | Supports pre-injection sample conditioning and advanced scheduling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III SFC Multisampler |
| Instrument Type | Supercritical Fluid Chromatography (SFC) Autosampler |
| Maximum Sample Capacity | 6144 |
| Injection Volume Range | 0.1–90 µL |
| Sample Container Compatibility | 2 mL Vials and Microtiter Plates (e.g., 96-well, 384-well) |
| Injection Technology | FEED (Forced Expansion and Efficient Delivery) |
| Temperature Control | Active Peltier-based Cooling/Heating |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Carryover | < 9 ppm |
| Temperature Control Range (Optional Integrated Chiller/Heater) | 4–40 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Switzerland |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | PAL3 Series 2 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity (2 mL vials) | up to 1458 (160 cm configuration) |
| Sample Capacity (10/20 mL vials) | up to 405 (160 cm configuration) |
| Compatible GC Platforms | Agilent 8890, 8860, Intuvo 9000, 7890, 7820 |
| Compatible Software | OpenLab CDS, MassHunter, ChemStation, EZChrom |
| Supported Sampling Modes | Liquid Injection, Static/Dynamic Headspace, SPME (Fiber & Arrow), RTC Tool Exchange |
| Integrated Sample Prep Functions | Dilution, Solvent Addition, Stirring, Centrifugation, Washing, Temperature-Controlled Handling |
| Consumables Intelligence | RFID/NFC-enabled smart chips for traceable usage history and automated reporting |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure | Up to 600 bar (standard), up to 800 bar (with optional high-pressure kit) |
| Carryover | <9 ppm |
| Temperature Control Range (optional integrated thermostat) | 4–40 °C |
| Sample Tray Configurations | Three-height drawer system supporting vials and microplates |
| Microplate Capacity | Up to 16 standard microplates per drawer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Temperature Control Range (optional integrated chiller/heater) | 4–40 °C |
| Sample Tray Flexibility | Three-height drawer configuration supporting vials and microplates (including shallow-format plates) |
| Carryover | <9 ppm with optional multi-wash and needle seat backflush |
| Sample Path Material | Biocompatible (low-binding, inert surfaces) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Markes International (OEM for Agilent) |
| Instrument Type | Thermal Desorption Autosampler for Gas Chromatography |
| Compatibility | Fully Integrated with Agilent GC and GC/MS Systems |
| Carrier Gases | Hydrogen, Helium, Nitrogen |
| Sample Capacity | Up to 100 Sorbent Tubes |
| Automation Mode | Stacked Tube Processing |
| Gas Configuration Options | 14-channel, 4-channel, or 3-channel online gas manifold |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity III Manual Injector |
| Instrument Type | HPLC Manual Injector |
| Maximum Operating Pressure | 600 bar |
| Footprint Compatibility | Designed to match all 1260 Infinity series modules |
| Column Mounting Option | Optional column holder integrated into baseplate |
| Valve Construction | Ceramic stator surface for wear resistance and long-term sealing integrity |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model Series | Lumin, AQUATek 100, Atomx |
| Instrument Type | Gas Chromatography (GC) Purge-and-Trap Sample Introduction System |
| Compliance | Designed for ASTM D5024, D6227, EPA Methods 502.2, 524.2, 624, 8260D, and ISO 15681-2 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Sample Tray Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 600 bar (G7129A) / 800 bar (G7129C) |
| Injection Volume Range | 0.1–100 µL (standard), extendable to 1500 µL (G7129C) or 1800 µL (G7129A) |
| Needle Wash Port | External surface rinse |
| Optional Integrated Column Oven | Temperature range 5 °C above ambient to 80 °C, accommodates two columns up to 30 cm |
| Optional Integrated Sample Thermostat | 4–40 °C temperature control |
| Internal Volume | Minimized design with bypass mode available |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Online Sample Manager |
| Instrument Type | HPLC Autosampler for Biopharmaceutical Applications |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Maximum System Pressure | 1300 bar |
| Temperature Control Range (Optional Integrated Thermostat) | 4–40 °C |
| Dilution Ratio | Up to 1:1000 |
| Sample Handling Modes | Flow-through injection, FEED (Fast Exchange and Dilution) injection, Retention mode with quenching and pre-processing capability |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Online Sampling Module |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Dilution Ratio | Up to 1:1000 |
| Sampling Interface | External process-coupled interface for PAT integration |
| Compatible Injection Modes | Flow-through injection and Agilent FEED (Fast Equilibration Enhanced Dilution) injection |