Empowering Scientific Discovery

Agilent Technologies (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-manufactured)
ModelNovoCyte Advanteon
PricingUpon Request
Technology PlatformSpectral Flow Cytometry
Instrument TypeFlow Cytometry Analyzer
Intended UseResearch-Only
Detection Channels19 (expandable to 21 fluorescence parameters)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelCytation 1
Temperature ControlFour-zone incubation up to 45 °C
Humidity ControlIntegrated with four-zone incubation system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-manufactured)
ModelNovoCyte Quanteon
PricingAvailable upon request
Technology PlatformAnalytical Flow Cytometry
Product CategoryFlow Cytometer for Cell Analysis
Intended UseResearch-only (Not for Diagnostic Use)
Lasers4
Fluorescence Detection Channels25
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported
ModelSeahorse XF Pro Consumables
Product TypeCell Metabolic Analysis System Consumables
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported
ModelProteoAnalyzer Components & Accessories
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ManufacturerAgilent Technologies
Product CategoryImported Instrument
ModelEL406
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelEpoch
Function TypeAbsorbance-Only Microplate Reader
Automation LevelFully Automated
Detector TypePhotodiode Array (PDA)
Wavelength Range200–999 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelEpoch2
Function TypeUV-Vis Absorbance-Only Microplate Reader
Automation LevelFully Automated
Assay ModesEndpoint, Kinetic, Spectral Scan
Curve Fitting OptionsLinear, Quadratic, Cubic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL), Log-Log, Spline
Detector TypeUV-Visible Photodiode Array
Wavelength Range200–999 nm (1 nm increments)
Absorbance Range0–4 OD
Absorbance Linearity±1% ± 0.01 OD (0–2 OD)
Plate Read Time8 sec (96-well), 14 sec (384-well)
Precision±1% ± 0.01 OD (0–2 OD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ManufacturerAgilent Technologies
Import StatusImported
ModelSeahorse XFp
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-manufactured)
ModelNovoCyte Opteon
PricingUpon Request
Technology PlatformSpectral Flow Cytometry
Instrument TypeFlow Cytometer
Primary Use CaseResearch
Laser Configuration3–5 Lasers (UV, Violet, Blue, Yellow, Red)
Automated Sample LoadingYes
Detector Count73
Validated Panel CapacityUp to 45-color
Forward/Side Scatter OptimizationDual-angle (405 nm & 488 nm SSC), enabling sub-80 nm particle resolution
Software PlatformNovoExpress v4.0+ with real-time acquisition, spectral unmixing, and GLP-compliant audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelBioStack
Instrument CategoryBiopharmaceutical Applications
Plate Capacity Options10 / 30 / 50 microplates
Compatible Well Formats6–1536-well plates
Automation LevelFully automated de-lidding and re-lidding
Integration ReadyYes — with Agilent BioTek washers, dispensers, multimode readers, imagers, and Synergy Neo2 systems
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginZhejiang, China
Manufacturer TypeManufacturer
Regional CategoryDomestic (China)
ModelRTCA eSight
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-manufactured)
ModelNovoCyte
PricingUpon Request
Technology PlatformSpectral Flow Cytometry
Instrument TypeBenchtop Flow Cytometer for Cell Analysis
Intended UseResearch-Only
Laser Configuration1–3 Solid-State Lasers
Detection Channels17-parameter Fluorescence Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelBioTek Synergy Neo2 Hybrid
Detection MethodsAbsorbance, Fluorescence Intensity (tunable bandwidth), Luminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP), TR-FRET, BRET, AlphaScreen/AlphaLISA
Detector TypesDual Photomultiplier Tubes (PMTs), Monochromator-based and Filter-based Optical Paths, 337 nm Pulsed Laser for TRF, 100 mW Solid-State Laser for Alpha Detection
AutomationFully Automated with BioStack Neo
Environmental Control4-Zone Temperature Control up to 70 °C, CO₂/O₂ Regulation, Anti-Condensation System, Linear & Orbital Shaking
Sample Formats6–1536-well Microplates, Take3/Take3 Trio Microvolume Plates, Petri Dishes, Cell Culture Dishes
SoftwareGen5 v3.1+ with LIMS Integration, FDA 21 CFR Part 11 Compliance Support, Audit Trail, Electronic Signatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelSynergy HTX
Function TypeMulti-Mode
Automation LevelFully Automated
Assay MethodsEndpoint, Kinetic, Well-Scanning
Curve Fitting OptionsLinear, Point-to-Point, Four-Parameter Logistic (4PL)
Detector TypesFluorescence, UV-Vis Absorbance, Luminescence, Time-Resolved Fluorescence (TRF), AlphaScreen/AlphaLISA
Wavelength RangeFilter-Based: 200–850 nm
Monochromator-Based200–999 nm
Absorbance Range0–4 OD
Absorbance Linearity<1% deviation from ideal linearity across 0–3.0 OD
96-Well Read Time14 seconds
Absorbance Precision±0.0001 OD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelSeahorse XF Pro
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model2100
Instrument TypeProtein Electrophoresis System
Primary DeviceMicrofluidic Capillary Electrophoresis Platform
Sample ThroughputUp to 12 Samples per Run
Sample Volume1–5 µL (varies by assay type)
RNA Quality MetricRNA Integrity Number (RIN)
Power Consumption60 VA
Safety ComplianceIEC 61010-1, Installation Category II, Pollution Degree 2
Laser ClassificationClass 1
Operating Temperature15–27 °C
Dimensions (W × D × H)162 mm × 412 mm × 290 mm
Weight10 kg
Input Voltage100–240 VAC
Input Frequency50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
ModelFragment Analyzer 5400
Instrument TypeNucleic Acid Electrophoresis System
Sample Throughput>2,400 samples per 24 hours
Voltage/Current100–240 VAC, 47–63 Hz
Dimensions (W × D × H)36 cm × 51 cm × 61 cm
Power Consumption150 VA
Operating Temperature19–25 °C
Relative Humidity20–80 % RH
Weight38.5 kg
Sample Format96-well plate per run
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelSynergy LX
Function TypeMultimode
Automation LevelFully Automated
Assay ModesEndpoint, Kinetic, Well-Scanning
Curve Fitting OptionsLinear, Point-to-Point, Four-Parameter Logistic (4PL)
Detector TypesUV-Vis Absorbance, Fluorescence Intensity, Luminescence
Wavelength RangeFilter-Based: 320–850 nm
Monochromator-Based200–999 nm
Absorbance Range0–4 OD
Absorbance Linearity<1% deviation from ideal over 0–2.5 OD
Read Time (96-well plate)12 s
Absorbance Precision±0.0001 OD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
ManufacturerAgilent Technologies
Country of OriginImported
ModelSureScan
Instrument TypeMicroarray Scanning System
Dimensions43 cm (W) × 67 cm (D) × 42 cm (H)
Laser Wavelengths532 nm, 640 nm
Laser ClassClass 1
Scan Resolutions2 µm, 3 µm, 5 µm, 10 µm
Pixel Positional Accuracy<1 µm (at 5 µm resolution)
Compatible DyesAlexa 555, Alexa 647, Alexa 660, Cy3, Cy5
Slide FormatStandard 1" × 3" (25 mm × 75 mm) glass slides, thickness 0.9–1.1 mm
Uniformity≤5% CV (global), ~1% (local, 100 µm features)
Detection Limit0.01 chromophore per µm²
AutofocusYes
Integrated Barcode ReaderCodabar, Code 128 (A/B/C), Code 39, Code 93
Operating Temperature15–30 °C
Relative Humidity15–85% RH
Max Altitude3000 m
Data Acquisition Time16 min (3 µm scan, 61 mm × 21.6 mm area), 24 min (2 µm scan)
Power Supply100–240 VAC, 50–60 Hz
ComplianceISO 13485-manufactured
Intended UseFor Research Use Only (RUO), Not for Diagnostic Use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China-manufactured)
ModelRTCA MP (6 × 96-well)
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model4200 TapeStation
Instrument TypeNucleic Acid Quality Control Electrophoresis System
Sample Capacity1–96 samples per run
Voltage/Current100–240 VAC, 50–60 Hz
Dimensions (W × D × H)435 mm × 510 mm × 445 mm
Power Consumption50 VA
Weight25.5 kg
Sample Volume Requirement1–2 µL per assay
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ManufacturerAgilent Technologies
Import CategoryImported Instrument
ModelXF HS Mini
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelCytation 7
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0