Agilent Technologies (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model1200
QuotationUpon Request
Instrument TypeTriple Quadrupole
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6230B
Instrument TypeTime-of-Flight (TOF) Mass Spectrometer
Mass Accuracy (Positive Mode)<1 ppm RMS
Acquisition Rate30 spectra/sec
Resolution (FWHM)>22,000 at m/z 1522, independent of acquisition speed
Mass Rangem/z 25–20,000
Ion SourcesESI, AJS-ESI, APCI, Dual ESI/APCI, NanoESI, CE-ESI, GC-APCI
Dynamic Range (within single spectrum)5 decades
Polarity Switching Duty Cycle<1 sec
Mass Stability<2 ppm / 2 °C
Software PlatformMassHunter Suite (including WalkUp, BioConfirm, Mass Profiler Professional, Vista, Flux)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model6230B
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF) LC/MS System
Mass Accuracy<1 ppm (RMS)
Mass Resolution>22,000 (FWHM at m/z 556)
Acquisition RateUp to 30 spectra/sec
Dynamic Range5 orders of magnitude
SensitivitySub-picomolar on-column detection (using Agilent Jet Stream ESI source)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
Model6546 LC/Q-TOF
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
Application FieldUniversal
Mass Rangem/z 20–10,000
SensitivityS/N (RMS) > 500:1 (measured with 1 pg reserpine on-column)
Resolution30,000–60,000 FWHM (mass-dependent, acquisition-rate independent)
Quadrupole Resolution (FWHM)1.3 Da (auto-tuned)
Mass Accuracy<0.8 ppm RMS (MS), <2 ppm RMS (MS/MS)
Isotopic Fidelity<5% error
Dynamic Range5 orders of magnitude (intra-spectrum)
Polarity Switching Duty Cycle1.5 s
Ion Source OptionsDual AJS ESI, APCI, ESI/APCI multimode, GC/APCI, NanoESI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6545
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6100
Instrument TypeSingle Quadrupole LC/MS (not Tandem Quadrupole)
Scan SpeedUp to 10,000 u/s
Detection LimitSub-picogram (with Agilent Jet Stream Technology on 6130/6150 variants)
CompatibilityFully Integrated with Agilent 1220/1260/1290 Infinity LC Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
ModelRevident LC/Q-TOF
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
Application FieldGeneral-Purpose Small-Molecule Analysis
Mass Rangem/z 20–10,000
Sensitivity<40 fg on-column reserpine (positive mode), <40 ppt (S/N ≥ 1000:1 for 1 pg on-column)
<40 fg on-column chloramphenicol (negative mode), <40 ppt (S/N ≥ 7501 for 1 pg on-column)
ResolutionTOF mass resolution (FWHM) >60,000 at m/z 2722, acquisition-rate independent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model6550A
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelAgilent InfinityLab LC/MSD iQ
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
Application ScopeGeneral-Purpose LC/MS Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer StatusOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
Model6475
Instrument TypeTandem Quadrupole (QqQ)
Application ScopeUniversal
Mass Rangem/z 5–3000
Sensitivity< 3.5 fg on-column reserpine (positive mode), < 3.5 ppt IDL (using Agilent Jet Stream Ion Source + Verification Column + 1290 Infinity II LC system)
Negative Mode IDL< 4 fg chloramphenicol, < 4 ppt IDL (same configuration)
MRM Transition Rate500 transitions/s
Quadrupole Resolution (FWHM)0.4 Da (narrow), 0.7 Da (unit mass), 1.2 Da (wide), 2.5 Da (broad)
Scan Speed18,700 Da/s
Minimum MRM Dwell Time0.5 ms
Polarity Switching Time< 25 ms
Collision Cell Cleaning Time< 1 ms
Ion SourcesESI, APCI, MultiMode (ESI/APCI), Nano-ESI, Agilent Jet Stream (AJS)
Dimensions (W × D × H)47.5 cm × 77.3 cm × 84 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6495
Instrument TypeTandem Quadrupole (QqQ) Mass Spectrometer
LC IntegrationFully Compatible with Agilent 1200/1290 UHPLC Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
ManufacturerAgilent Technologies
Import StatusImported
Model6470B
Instrument TypeTriple Quadrupole (TQ)
Application ScopeGeneral-Purpose
Mass Rangem/z 5–3000
Sensitivity< 4 fg on-column ritalin (reserpine), < 4 ppt in solution
Resolution ModesNarrow = 0.4 Da, Unit = 0.7 Da, Wide = 1.2 Da, Widest = 2.5 Da
Pressure RangeNot applicable (vacuum-operated system)
Ion SourcesAgilent Jet Stream (AJS), Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Multi-Mode Ionization (MMI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
ManufacturerAgilent Technologies
Import StatusImported
Model6470
Instrument TypeTandem Quadrupole (QqQ)
Application ScopeUniversal
SensitivityUp to 5× higher than conventional ESI sources
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelUltivo
Instrument TypeTandem Quadrupole (QqQ)
SensitivityIDL < 12.5 fg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6495D
Instrument TypeTandem Quadrupole (QqQ)
Application ScopeGeneral-Purpose Targeted Quantitation
Mass Rangem/z 5–3000
Resolution (FWHM)Unit Mass = 0.7 Da
MRM Transition Rate700 transitions/s
Minimum MRM Dwell Time0.5 ms
Polarity Switching Speed<25 ms
Ion SourcesESI, AJS-ESI, APCI, Dual ESI/APCI, Nano-ESI
Vacuum Pump OptionsMS120 Roughing Pump or Edwards nXL200i Oil-Free Dry Pump (Optional)
Collision Cell Clean Time<1 ms
Dimensions (W×D×H)91.5 cm × 77.3 cm × 47.5 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import CategoryImported Instrument
ModelInfinityLab Pro iQ / Pro iQ Plus
Instrument TypeSingle-Quadrupole Mass Spectrometer
Application ScopeGeneral-Purpose LC/MS Detection
Mass Rangem/z 2–1600 (Pro iQ)
Sensitivity< 100 fg on-column (Pro iQ, ESI positive mode, reserpine)
Ion SourcesESI, APCI, Dual ESI/APCI (MMI), AJS (Pro iQ Plus only)
Vacuum SystemAgilent MS45 rotary vane pump
SIM Minimum Dwell Time1 ms
Polarity Switching Speed< 15 ms
Dynamic RangeUp to 6 orders of magnitude (linear)
Dimensions (W × D × H)39.6 cm × 54.8 cm × 35.0 cm
Software PlatformOpenLab CDS (v2.8 FP2 and later), MassHunter WalkUp, MassWorks Oligonucleotide Analyzer, Deconvolution Accelerator for OpenLab CDS
Key TechnologiesCyclone Ion Guide, Hyperbolic Quadrupole Mass Analyzer, VacShield Vacuum Shield, SWARM Auto-Tuning, InfinityLab Assist Interactive Touch Interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6495C
Instrument TypeTandem Quadrupole (Triple Quadrupole)
Application ScopeGeneral-Purpose Quantitative and Qualitative Analysis
Mass Range5–3000 m/z
Ion Source MaintenanceVacuum-Shield Enabled (No Vent Required)
Key TechnologyThird-Generation All-Metal iFunnel, Triggered Multiple Reaction Monitoring (tMRM), Direct Skyline Integration, MassHunter Software Platform
Regulatory ComplianceDesigned for US FDA 21 CFR Part 11, EU Annex 11, and GLP/GMP Data Integrity Requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelLC/MSD
Instrument TypeSingle Quadrupole
Application ScopeGeneral-Purpose
Mass Rangem/z 10–2000
Scan Speed10,400 Da/s
Minimum SIM Dwell Time5 ms
Polarity Switching Time< 300 ms
Ion SourcesESI, APCI, Multi-Mode (ESI + APCI)
Dimensions (W × D × H)44.3 cm × 63.5 cm × 47.0 cm
Compatible SoftwareOpenLab CDS, OpenLab ChemStation, MassHunter WalkUp, MassWorks Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model6530B
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelLC/MSD XT
Instrument TypeSingle Quadrupole
SensitivitySub-pg on-column detection limit (e.g., 500 fg injected for caffeine in ESI positive mode)
Ionization SourcesElectrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Atmospheric Pressure Photoionization (APPI), Agilent Jet Stream (AJS) ESI/APCI, Dual-Mode Source
Mass Rangem/z 10–3000
Scan SpeedUp to 10,000 Da/sec
Polarity Switching< 200 ms
Software PlatformOpenLAB CDS (Chemical Workstation), compliant with FDA 21 CFR Part 11 and EU Annex 11
Calibration TechnologyMassWorks™ high-accuracy mass calibration (Cerno Bioscience integration)
Form FactorStackable module compatible with Agilent 1260/1290 Infinity II LC systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model6560 LC/Q-TOF
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
Application FieldGeneral-Purpose
Mass Rangem/z 20–20,000
SensitivityS/N (RMS) > 50:1 (measured with 1 pg reserpine on-column)
Resolution>42,000 FWHM at m/z 2722, acquisition-rate independent
Ion Mobility Resolution (FWHM)>200
Quadrupole Mass Rangem/z 20–4000
Quadrupole Resolution (FWHM)1.3 Da (auto-tuned)
Mass Accuracy (MS, positive mode)<1 ppm RMS
MS/MS Mass Accuracy (positive mode)<2 ppm RMS
MS Acquisition Rate50 spectra/sec
MS/MS Acquisition Rate30 spectra/sec
Dynamic Range (within-spectrum)5 orders of magnitude
Ion SourcesDual AJSM, MultiMode (ESI/APCI), Dual ESI, GC/APCI, APCI, NanoESI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model6495B
Instrument TypeTandem Quadrupole (QqQ)
Mass Rangem/z 3000
Ion SourceElectrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI)
Key TechnologyiFunnel Ion Optics
Maintenance FeaturePlug-and-Play Ion Source with Vacuum Isolation Valve
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginSingapore
ManufacturerAgilent Technologies
Origin CategoryImported
Model6545XT
Instrument TypeQuadrupole-Time-of-Flight (Q-TOF)
MS Sensitivity (Positive Ion, S/N RMS)>500:1 @ 1 pg reserpine on-column
MS Mass Accuracy (Positive/Negative Ion)<0.8 ppm RMS
MS Acquisition Rate50 spectra/sec
MS/MS Sensitivity (Positive Ion, S/N RMS)>1500:1 @ 1 pg reserpine on-column
MS/MS Mass Accuracy (Positive/Negative Ion)<2 ppm RMS
MS/MS Acquisition Rate30 spectra/sec
TOF Mass Resolution (FWHM)>50,000 @ m/z 2722, independent of acquisition rate
TOF Mass Rangem/z 20–30,000
Quadrupole Isolation Rangem/z 20–4,000
Quadrupole Resolution (FWHM)1.3 Da (auto-tuned)
Polarity Switching Duty Cycle1.5 s
Internal Calibration Stability<1 ppm / 3 °C
Dynamic Range within Single Spectrum5 orders of magnitude
Ion SourcesDual AJS-ESI, APCI, ESI/APCI multimode, GC/APCI, NanoESI