| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 4000 |
| Optical Design | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–900 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 0.01–5.00 nm (variable) |
| Photometric Range | 0–8.0 Abs |
| Light Sources | Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Maximum Scan Speed | 2000 nm/min |
| Sample Compartment Z-Height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 7000 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 10 Abs |
| Max Scan Speed | UV-Vis 2000 nm/min, NIR 8000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 5000 |
| Optical Design | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Photometric Range | ±8.0 Abs |
| Scan Speed | UV-Vis up to 2000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Purge | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 60 UV-Vis |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.5 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 6000i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–1800 nm (UV-Vis-NIR) |
| Automation Level | Motorized wavelength scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 8.0 Abs |
| Scan Speed | UV-Vis: 2000 nm/min |
| NIR | 8000 nm/min |
| Sample Compartment Z-height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Purge Capability | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 3500 |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.1 – 5.0 nm (UV-Vis) |