Empowering Scientific Discovery

Agilent Technologies (China) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model1290 Infinity III Diode Array Detector
Instrument TypeDiode Array Detector (DAD)
Noise Level< ±3 µAU (10 mm flow cell, 1 s response time)
Signal ChannelsUp to 8 simultaneous wavelength channels
Spectral Acquisition RateUp to 240 Hz
Optical Path Length Options10 mm (standard), 60 mm (high-sensitivity flow cell)
Baseline Drift< ±0.6 µAU/cm (60 mm flow cell)
Linear Dynamic RangeUp to 2.5 AU (standard)
Slit Width Programmability1–8 nm
Temperature ControlElectronic Temperature Control (ETC) with RFID-tracked flow cell and lamp modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model1290 Infinity III RID
Instrument TypeRefractive Index Detector (RID)
Compatible SystemUltra-High Performance Liquid Chromatography (UHPLC)
Flow Cell DesignUltra-Low Dispersion Micro-Flow Cell
Data Acquisition Rate148 Hz
Detection PrincipleDifferential Refractometry
ComplianceDesigned for GLP/GMP environments with support for FDA 21 CFR Part 11–compliant software workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1260 Infinity III High-Sensitivity Diode Array Detector (HS)
Detection PrincipleUV-Vis Absorption Spectrophotometry via Fixed-Slit DAD Architecture
Noise Level< ±3 µAU (typical baseline noise, 1 s bandwidth, 254 nm, 10 mm pathlength cell)
Signal ChannelsUp to 8 simultaneous wavelength-specific absorbance signals
Data Acquisition RateUp to 120 Hz (full-spectrum acquisition)
Flow CellAgilent Max-Light Cartridge Flow Cell with Optical Waveguide, 10 mm pathlength (standard), 60 mm pathlength option available (< ±0.6 µAU/cm noise)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Modelmicro-ECD
Compatible InstrumentGas Chromatograph (GC)
Detector TypeElectron Capture Detector (ECD)
Detection PrincipleRadioisotope-based electron capture
Minimum Detectable Level (MDL) for Lindane3.8 fg/mL
Linear Dynamic Range5 × 10⁴ (fg/mL to ng/mL)
Sampling Rate5–500 Hz
ComplianceU.S. EPA Contract Laboratory Program (CLP) Method 8081B/8270 for pesticide analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model1260 Infinity III Fluorescence Detector with Full-Spectrum Acquisition
Instrument TypeFluorescence Detector (FD)
Detection LimitRaman Signal-to-Noise Ratio > 3000 (measured against dark signal noise reference)
Data Acquisition RateUp to 148 Hz
CompatibilityFully compatible with Agilent InfinityLab LC systems and third-party HPLC platforms
Flow CellBio-inert, optimized for biomolecular applications
Light SourceLong-life pulsed xenon lamp (> 4000 h), integrated lamp reference system
Optical DesignSimplified optical path for superior baseline stability
Spectral CapabilityReal-time full-spectrum acquisition synchronized with chromatographic elution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model1290 Infinity III Wide Dynamic Range DAD
Instrument TypeDiode Array Detector (DAD)
Compatible SystemAgilent InfinityLab LC Systems
Data Acquisition RateUp to 120 Hz (DAD FS variant)
Linear UV Dynamic Range Extension30× vs. conventional DAD
Temperature ControlSecond-Generation Electronic Temperature Control (ETC)
Cell & Lamp IdentificationRFID-enabled for audit-trail compliance
Flow Cell PathlengthsDual-path, optimized for high- and low-concentration analytes
Regulatory SupportDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1260 Infinity III Variable Wavelength Detector
Compatible SystemHigh-Performance Liquid Chromatography (HPLC)
Detector TypeUV-Vis Absorbance Detector
Data Acquisition RateUp to 120 Hz
Dual-Wavelength ModeYes
Baseline Noise< ±0.25 × 10⁻⁵ AU
Drift< 0.5 × 10⁻⁴ AU/h
Linear Range> 2.5 AU
Wavelength Accuracy±1 nm (verified via built-in holmium oxide filter)
Temperature ControlElectronic Temperature Control (ETC) with active stabilization
Flow Cell Options8 interchangeable analytical and preparative flow cells (including 10 mm, 60 mm pathlengths
RFID IntegrationYes (for cell/lamp identification and usage traceability)
EMF SupportYes (lamp hours, maintenance alerts, user-defined thresholds)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginShanghai, China
ManufacturerAgilent Technologies (Shanghai) Co., Ltd.
TypeNitrogen-Phosphorus Detector (NPD)
Compatible InstrumentGas Chromatograph (GC)
Bead MaterialHigh-Performance Glass-Based Blos Rubidium Bead
Lifetime≥2× that of conventional ceramic rubidium beads
N-Compound SensitivityComparable to ceramic beads
P-Compound SensitivityEnhanced vs. ceramic beads
Environmental ToleranceHigh resistance to ambient humidity and moisture exposure
Regulatory ComplianceDesigned for use in GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1290 Infinity III Variable Wavelength Detector
Compatible SystemHigh-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC)
Detector TypeUV-Vis Absorbance Detector
Data Acquisition RateUp to 240 Hz
Baseline Noise< ±0.25 × 10⁻⁵ AU
Drift< 0.5 × 10⁻⁴ AU/h
Linear Dynamic Range> 2.5 AU
Wavelength Range190–950 nm
Wavelength Accuracy±0.1 nm (verified via built-in holmium oxide filter)
Temperature ControlElectronic Temperature Control (ETC) with ±0.05 °C stability
Flow Cell IdentificationRFID-enabled stainless steel or fused silica flow cells
Lamp Life MonitoringReal-time EMF tracking with user-defined thresholds
Software IntegrationFully compatible with OpenLab CDS, MassHunter, and compliant with FDA 21 CFR Part 11 audit trail requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelFlame Ionization Detector
Compatible InstrumentsAgilent Intuvo 9000, 8890, 8860, and 7890 Series Gas Chromatographs
Detection Limit (n-tridecane)≤1.2 pg C/s (8890 GC), ≤1.4 pg C/s (Intuvo 9000 & 7890B GC), ≤3 pg C/s (8860 GC)
Linear Dynamic Range>10⁷ (±10%)
Data Acquisition RateUp to 1000 Hz (Intuvo 9000 & 8890 GC)
Maximum Operating Temperature450 °C (8890/7890B/Intuvo 9000), 425 °C (8860)
Column CompatibilityCapillary-optimized or universal (capillary & packed column) variants available
Mounting FlexibilityOptional third-detector position on 8890 GC left side
Ignition ControlAuto-ignition and flame-out detection with recovery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
Model8355 SCD
PricingAvailable Upon Request
Compatible InstrumentGas Chromatograph (GC)
Detector TypeElemental-Specific Chromatographic Detector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model1260 Infinity III RID
Detection PrincipleDifferential Refractometry
Compatible SystemsAgilent 1200/1260/1290 Series HPLC & UHPLC Platforms
Detection ModeDual-Flow, Solvent-Compensated RI
Data Acquisition Rate74 Hz
Baseline Noise< 2.5 nRIU (typical, 1 sec time constant)
Temperature ControlElectronic Thermal Control (ETC), 5–55 °C, ±0.01 °C stability
Flow Cell Volume8 µL
Lamp TypeTungsten-Halogen, Lifetime > 2000 h
Auto-CompensationDynamic light intensity adjustment for lamp aging and flow cell fouling
Maintenance AccessFront-panel serviceable fluidic path and valves
EMF MonitoringReal-time tracking of purge duration, lamp operating hours, and system diagnostics
Software IntegrationFully compatible with OpenLab CDS (ChemStation Edition), compliant with FDA 21 CFR Part 11 audit trail requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model1260 Infinity III Diode Array Detector WR
Instrument TypeDiode Array Detector (DAD)
Wavelength Range190–950 nm
Short-Term Noise< ±7 µAU (ASTM compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1260 Infinity III ELSD
Detection PrincipleEvaporative Light Scattering Detection
Compatible SystemsAgilent 1260 Infinity III LC, Other HPLC/UHPLC Platforms via Analog/Digital I/O
Operating Temperature RangeUp to 120 °C
Carrier GasNitrogen or Compressed Air
Detection SensitivitySub-nanogram (ng) Level for Non-Volatile and Semi-Volatile Analytes
Baseline StabilityMinimal Drift (<0.5 mV/h after equilibration)
Data Acquisition RateUp to 100 Hz
ReproducibilityRSD < 2% (n = 6, repeated injections)
Solvent CompatibilityFully compatible with DMSO, THF, DMF, chlorinated solvents, and high-boiling-point mobile phases
Regulatory ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1260 Infinity III Multi-Wavelength Detector
Compatible SystemHPLC
Detector TypeDiode Array Detector (DAD)
Wavelength Range190–950 nm
Short-Term Noise< ±7 µAU (ASTM E1657-05)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic Instrument
Model8255 NCD
PricingAvailable Upon Request
Compatible InstrumentGas Chromatograph (GC)
Detector TypeSelective Nitrogen-Specific Detector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model1260 Infinity III FLD
Detection PrincipleDual-wavelength Programmable Fluorescence Detection
Compatible SystemsAgilent InfinityLab LC Systems & Third-party HPLC Platforms
Detection LimitRaman S/N > 3000 (measured against dark signal noise reference)
Data Acquisition RateUp to 74 Hz
Detector TypeFluorescence Detector (FD)
Flow Cell InterfaceCartridge-style flow cell with auto-identification
Regulatory Compliance SupportGLP-compliant parameter logging, audit-ready metadata capture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1290 Infinity III ELSD
Detection PrincipleEvaporative Light Scattering Detection
CompatibilityIntegrated with Agilent 1290 Infinity III LC Systems and Third-Party HPLC Platforms
SensitivitySub-nanogram detection capability for non-UV-absorbing analytes
Temperature Control RangePeltier-cooled evaporator, 10–80 °C
Dynamic RangeFour decades (10⁴)
ReproducibilityRSD < 2% (n ≥ 6 injections, standard test conditions)
Response Time< 0.1 s
Data Acquisition RateUp to 100 Hz
Gas Flow ControlProgrammable, real-time nitrogen or air flow (0–3.0 L/min)
Solvent CompatibilityFully compatible with gradient elution using volatile and semi-volatile mobile phases including acetonitrile, methanol, THF, and aqueous buffers — DMSO-free operation enabled
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelTCD for GC Systems
Compatible InstrumentsAgilent Intuvo 9000, 8890, 8860, and 7890 Gas Chromatographs
Detector TypeUniversal Thermal Conductivity Detector
Baseline DriftUltra-low drift enabled by proprietary fluid-switching architecture with rapid post-startup stabilization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model1290 Infinity III Diode Array Detector FS
Detection PrincipleUV-Vis Absorbance Spectroscopy via Photodiode Array
Instrument TypeDiode Array Detector (DAD)
Noise Level±0.6 µAU/cm (with 60 mm pathlength flow cell)
Signal ChannelsUp to 8 simultaneous wavelength-specific signals
Sampling RateUp to 240 Hz
Flow Cell OptionsMaxLight™ cartridge flow cells (10 mm and 60 mm pathlengths)
ComplianceDesigned for GLP/GMP environments
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0