- All
- Favorite
- Popular
- Most rated
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | ProteoAnalyzer Components & Accessories |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2100 |
| Instrument Type | Protein Electrophoresis System |
| Primary Device | Microfluidic Capillary Electrophoresis Platform |
| Sample Throughput | Up to 12 Samples per Run |
| Sample Volume | 1–5 µL (varies by assay type) |
| RNA Quality Metric | RNA Integrity Number (RIN) |
| Power Consumption | 60 VA |
| Safety Compliance | IEC 61010-1, Installation Category II, Pollution Degree 2 |
| Laser Classification | Class 1 |
| Operating Temperature | 15–27 °C |
| Dimensions (W × D × H) | 162 mm × 412 mm × 290 mm |
| Weight | 10 kg |
| Input Voltage | 100–240 VAC |
| Input Frequency | 50–60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Fragment Analyzer 5400 |
| Instrument Type | Nucleic Acid Electrophoresis System |
| Sample Throughput | >2,400 samples per 24 hours |
| Voltage/Current | 100–240 VAC, 47–63 Hz |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % RH |
| Weight | 38.5 kg |
| Sample Format | 96-well plate per run |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4200 TapeStation |
| Instrument Type | Nucleic Acid Quality Control Electrophoresis System |
| Sample Capacity | 1–96 samples per run |
| Voltage/Current | 100–240 VAC, 50–60 Hz |
| Dimensions (W × D × H) | 435 mm × 510 mm × 445 mm |
| Power Consumption | 50 VA |
| Weight | 25.5 kg |
| Sample Volume Requirement | 1–2 µL per assay |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4150 TapeStation |
| Instrument Type | Nucleic Acid Quality Control Electrophoresis System |
| Sample Capacity | Up to 16 samples per run |
| Input Voltage | 100–240 VAC, 50–60 Hz |
| Dimensions (W × D × H) | 254 mm × 510 mm × 417 mm |
| Power Consumption | 50 VA |
| Weight | 17.8 kg |
| Sample Volume Requirement | 1–2 µL per assay |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ProteoAnalyzer System |
| Instrument Type | Capillary Electrophoresis (CE-SDS) Analyzer for Proteins |
| Sample Capacity | 12 samples per run |
| Voltage/Current Input | 100–240 VAC, 47–63 Hz |
| Dimensions (W × D × H) | 35 cm × 51 cm × 61 cm |
| Weight | 38.5 kg |
| Power Consumption | 150 VA |
| Operating Relative Humidity | 20–80 % RH |
| Temperature Range | Ambient (15–30 °C) |
| Detection Sensitivity | ≥1 ng/µL BSA in PBS |
| Linear Dynamic Range | 2–2000 ng/µL BSA in PBS |
| Separation Range | 10–240 kDa |
| Capillary Format | Parallel capillary array with on-capillary fluorescence detection |
| Separation Chemistry | Capillary Gel Electrophoresis (CGE) with SDS denaturation and covalent fluorescent labeling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | ProteoAnalyzer 12-Capillary Array |
| Pricing | Available Upon Request |
Show next