| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Hybrid Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Diode Array Detector |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | < ±3 µAU (10 mm flow cell, 1 s response time) |
| Signal Channels | Up to 8 simultaneous wavelength channels |
| Spectral Acquisition Rate | Up to 240 Hz |
| Optical Path Length Options | 10 mm (standard), 60 mm (high-sensitivity flow cell) |
| Baseline Drift | < ±0.6 µAU/cm (60 mm flow cell) |
| Linear Dynamic Range | Up to 2.5 AU (standard) |
| Slit Width Programmability | 1–8 nm |
| Temperature Control | Electronic Temperature Control (ETC) with RFID-tracked flow cell and lamp modules |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Bio-Inert Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Operating Pressure | Up to 600 bar |
| Carryover | <9 ppm |
| Temperature Control Range (Optional) | 4–40 °C |
| Flow Path Materials | Ceramic needle, PEEK needle seat, stainless-steel-coated PEEK capillary |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1290 Infinity III RID |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | Ultra-High Performance Liquid Chromatography (UHPLC) |
| Flow Cell Design | Ultra-Low Dispersion Micro-Flow Cell |
| Data Acquisition Rate | 148 Hz |
| Detection Principle | Differential Refractometry |
| Compliance | Designed for GLP/GMP environments with support for FDA 21 CFR Part 11–compliant software workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III High-Sensitivity Diode Array Detector (HS) |
| Detection Principle | UV-Vis Absorption Spectrophotometry via Fixed-Slit DAD Architecture |
| Noise Level | < ±3 µAU (typical baseline noise, 1 s bandwidth, 254 nm, 10 mm pathlength cell) |
| Signal Channels | Up to 8 simultaneous wavelength-specific absorbance signals |
| Data Acquisition Rate | Up to 120 Hz (full-spectrum acquisition) |
| Flow Cell | Agilent Max-Light Cartridge Flow Cell with Optical Waveguide, 10 mm pathlength (standard), 60 mm pathlength option available (< ±0.6 µAU/cm noise) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Sample Bottle Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 1300 bar |
| Injection Volume Range | Up to 1500 µL |
| Needle Wash Port | External surface rinse capability |
| Optional Integrated Column Oven | Temperature range 5–80 °C above ambient, accommodates two columns up to 30 cm length |
| Optional Integrated Sample Thermostat | Temperature control from 4–40 °C |
| Internal System Volume | Minimized design with bypass mode available |
| Overlapped Run/Injection Cycle | Enabled for throughput optimization |
| Programmable Sequence Logic | Supports pre-injection sample conditioning and advanced scheduling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III SFC Multisampler |
| Instrument Type | Supercritical Fluid Chromatography (SFC) Autosampler |
| Maximum Sample Capacity | 6144 |
| Injection Volume Range | 0.1–90 µL |
| Sample Container Compatibility | 2 mL Vials and Microtiter Plates (e.g., 96-well, 384-well) |
| Injection Technology | FEED (Forced Expansion and Efficient Delivery) |
| Temperature Control | Active Peltier-based Cooling/Heating |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | micro-ECD |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Electron Capture Detector (ECD) |
| Detection Principle | Radioisotope-based electron capture |
| Minimum Detectable Level (MDL) for Lindane | 3.8 fg/mL |
| Linear Dynamic Range | 5 × 10⁴ (fg/mL to ng/mL) |
| Sampling Rate | 5–500 Hz |
| Compliance | U.S. EPA Contract Laboratory Program (CLP) Method 8081B/8270 for pesticide analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Carryover | < 9 ppm |
| Temperature Control Range (Optional Integrated Chiller/Heater) | 4–40 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Switzerland |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | PAL3 Series 2 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity (2 mL vials) | up to 1458 (160 cm configuration) |
| Sample Capacity (10/20 mL vials) | up to 405 (160 cm configuration) |
| Compatible GC Platforms | Agilent 8890, 8860, Intuvo 9000, 7890, 7820 |
| Compatible Software | OpenLab CDS, MassHunter, ChemStation, EZChrom |
| Supported Sampling Modes | Liquid Injection, Static/Dynamic Headspace, SPME (Fiber & Arrow), RTC Tool Exchange |
| Integrated Sample Prep Functions | Dilution, Solvent Addition, Stirring, Centrifugation, Washing, Temperature-Controlled Handling |
| Consumables Intelligence | RFID/NFC-enabled smart chips for traceable usage history and automated reporting |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Fluorescence Detector with Full-Spectrum Acquisition |
| Instrument Type | Fluorescence Detector (FD) |
| Detection Limit | Raman Signal-to-Noise Ratio > 3000 (measured against dark signal noise reference) |
| Data Acquisition Rate | Up to 148 Hz |
| Compatibility | Fully compatible with Agilent InfinityLab LC systems and third-party HPLC platforms |
| Flow Cell | Bio-inert, optimized for biomolecular applications |
| Light Source | Long-life pulsed xenon lamp (> 4000 h), integrated lamp reference system |
| Optical Design | Simplified optical path for superior baseline stability |
| Spectral Capability | Real-time full-spectrum acquisition synchronized with chromatographic elution |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Wide Dynamic Range DAD |
| Instrument Type | Diode Array Detector (DAD) |
| Compatible System | Agilent InfinityLab LC Systems |
| Data Acquisition Rate | Up to 120 Hz (DAD FS variant) |
| Linear UV Dynamic Range Extension | 30× vs. conventional DAD |
| Temperature Control | Second-Generation Electronic Temperature Control (ETC) |
| Cell & Lamp Identification | RFID-enabled for audit-trail compliance |
| Flow Cell Pathlengths | Dual-path, optimized for high- and low-concentration analytes |
| Regulatory Support | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 120 Hz |
| Dual-Wavelength Mode | Yes |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Range | > 2.5 AU |
| Wavelength Accuracy | ±1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with active stabilization |
| Flow Cell Options | 8 interchangeable analytical and preparative flow cells (including 10 mm, 60 mm pathlengths |
| RFID Integration | Yes (for cell/lamp identification and usage traceability) |
| EMF Support | Yes (lamp hours, maintenance alerts, user-defined thresholds) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure | Up to 600 bar (standard), up to 800 bar (with optional high-pressure kit) |
| Carryover | <9 ppm |
| Temperature Control Range (optional integrated thermostat) | 4–40 °C |
| Sample Tray Configurations | Three-height drawer system supporting vials and microplates |
| Microplate Capacity | Up to 16 standard microplates per drawer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Agilent Technologies (Shanghai) Co., Ltd. |
| Type | Nitrogen-Phosphorus Detector (NPD) |
| Compatible Instrument | Gas Chromatograph (GC) |
| Bead Material | High-Performance Glass-Based Blos Rubidium Bead |
| Lifetime | ≥2× that of conventional ceramic rubidium beads |
| N-Compound Sensitivity | Comparable to ceramic beads |
| P-Compound Sensitivity | Enhanced vs. ceramic beads |
| Environmental Tolerance | High resistance to ambient humidity and moisture exposure |
| Regulatory Compliance | Designed for use in GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Temperature Control Range (optional integrated chiller/heater) | 4–40 °C |
| Sample Tray Flexibility | Three-height drawer configuration supporting vials and microplates (including shallow-format plates) |
| Carryover | <9 ppm with optional multi-wash and needle seat backflush |
| Sample Path Material | Biocompatible (low-binding, inert surfaces) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 240 Hz |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Dynamic Range | > 2.5 AU |
| Wavelength Range | 190–950 nm |
| Wavelength Accuracy | ±0.1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with ±0.05 °C stability |
| Flow Cell Identification | RFID-enabled stainless steel or fused silica flow cells |
| Lamp Life Monitoring | Real-time EMF tracking with user-defined thresholds |
| Software Integration | Fully compatible with OpenLab CDS, MassHunter, and compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Product Origin | Imported |
| Model | 1290 Infinity III MCT |
| Temperature Control | Peltier-based cooling and heating |
| Temperature Range | −20 °C below ambient to 110 °C |
| Maximum Column Capacity | 8 × 10 cm or 4 × 30 cm columns |
| Pressure Rating | 1300 bar |
| Column Identification | RFID-based tracking for up to 8 columns |
| Door Orientation | 90° or 180° configurable, removable for full access |
| Quick Connect Compatibility | InfinityLab Quick Connect fittings and thermal exchangers |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Load Lock |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Power Requirement | Pneumatic (Compressed Air Only) |
| Column Compatibility | Three Standard Bore Sizes |
| Compression Mode | Dual-Mode DAC + Static Axial Compression (SAC) |
| Application Scale | Milligram to Multi-Kilogram Preparative Chromatography |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Agilent 7697A |
| Sample Vial Capacity (Standard) | 111 positions, including 3 priority vial slots |
| Sample Vial Capacity (Optional) | 12-position configuration for academic or low-throughput labs |
| Vial Sizes Supported | 10 mL, 20 mL, and 22 mL vials without adapters |
| Injection Valve Loop Volume | Not specified in source data |
| Carrier Gas Compatibility | Hydrogen (H₂), Helium (He), Nitrogen (N₂) |
| Leak Detection | Automated, real-time vial pressure integrity check prior to analysis |
| Pressure Control | Independent headspace vial pressure and column head pressure regulation |
| Barcoding | Integrated sample vial barcode reader with LIMS-compatible data transmission |
| Method Transfer | Cross-platform method conversion and rapid re-optimization via Agilent Method Translation Software |
| Multi-HeadSpace Modes | Multiple Headspace Extraction (MHE) up to 100 cycles per vial |
| Vial Depressurization | Automatic post-analysis vial depressurization before return to tray |
| Interface | GC inlet-compatible transfer line kit for co-location with Agilent 7693A ALS on same GC inlet |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Flame Ionization Detector |
| Compatible Instruments | Agilent Intuvo 9000, 8890, 8860, and 7890 Series Gas Chromatographs |
| Detection Limit (n-tridecane) | ≤1.2 pg C/s (8890 GC), ≤1.4 pg C/s (Intuvo 9000 & 7890B GC), ≤3 pg C/s (8860 GC) |
| Linear Dynamic Range | >10⁷ (±10%) |
| Data Acquisition Rate | Up to 1000 Hz (Intuvo 9000 & 8890 GC) |
| Maximum Operating Temperature | 450 °C (8890/7890B/Intuvo 9000), 425 °C (8860) |
| Column Compatibility | Capillary-optimized or universal (capillary & packed column) variants available |
| Mounting Flexibility | Optional third-detector position on 8890 GC left side |
| Ignition Control | Auto-ignition and flame-out detection with recovery |
Show next