- All
- Favorite
- Popular
- Most rated
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 280Z GFAA |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-Beam |
| Background Correction | Zeeman Effect |
| Atomizer | GTA 120 Zeeman Graphite Furnace |
| Light Source Configuration | Up to 8 Fixed-Lamp Positions |
| Detector | Photomultiplier Tube (PMT) |
| Calibration Method | Polynomial Interpolation |
| Software Platform | Windows-Based Worksheet Interface |
| Optional Hydride Generation Compatibility | VGA Adapter Available |
| Temperature Control Architecture | Isothermal Zone Graphite Furnace Design |
| Lamp Technology | UltrAA Hollow Cathode Lamps (AC-Modulated) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 240Z AA |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | ≤0.2 nm |
| Repeatability (RSD) | <2% |
| Detection Limit (Cd) | ≤0.006 µg/L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 240FS AA |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Sensitivity | Mark 7 Atomization System — Cu 5 mg/L typically yields >0.9 Abs |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 280FS AA |
| Instrument Type | Flame AAS |
| Monochromator Type | Fixed-grating with high-resolution etched grating |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Lamp Capacity | 8-lamp turret with automatic selection |
| Atomization System | Mark 7 Flame Burner Assembly |
| Sensitivity | >0.9 Abs for 5 mg/L Cu |
| Sample Volume per Analysis | 10 mL |
| Multi-element Throughput | Up to 10 elements per sample in <2 minutes |
| Calibration Automation | SIPS 10/20 Integrated Sample Introduction and Dilution System |
| Software Platform | SpectrAA Method Development Suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AA DUO |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator Type | Custom High-Resolution Echelle Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Zeeman Effect |
| Linear Dynamic Range | Sub-ppt to Percent-Level Concentrations |
| Automation | Fully Integrated Dual-Atomizer Control via Agilent Workstation Software |
| Compliance | Designed for GLP/GMP environments |
Show next