BrandAgilent Technologies
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Model280Z GFAA
Instrument TypeGraphite Furnace Atomic Absorption Spectrometer
Optical SystemDual-Beam
Background CorrectionZeeman Effect
AtomizerGTA 120 Zeeman Graphite Furnace
Light Source ConfigurationUp to 8 Fixed-Lamp Positions
DetectorPhotomultiplier Tube (PMT)
Calibration MethodPolynomial Interpolation
Software PlatformWindows-Based Worksheet Interface
Optional Hydride Generation CompatibilityVGA Adapter Available
Temperature Control ArchitectureIsothermal Zone Graphite Furnace Design
Lamp TechnologyUltrAA Hollow Cathode Lamps (AC-Modulated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model240Z AA
Instrument TypeGraphite Furnace AAS
MonochromatorEchelle Grating
Optical SystemDouble-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionZeeman Effect
Spectral Resolution≤0.2 nm
Repeatability (RSD)<2%
Detection Limit (Cd)≤0.006 µg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
Model240FS AA
Instrument TypeFlame AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp (D₂)
SensitivityMark 7 Atomization System — Cu 5 mg/L typically yields >0.9 Abs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
Model280FS AA
Instrument TypeFlame AAS
Monochromator TypeFixed-grating with high-resolution etched grating
Optical SystemDual-beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp (D₂)
Lamp Capacity8-lamp turret with automatic selection
Atomization SystemMark 7 Flame Burner Assembly
Sensitivity>0.9 Abs for 5 mg/L Cu
Sample Volume per Analysis10 mL
Multi-element ThroughputUp to 10 elements per sample in <2 minutes
Calibration AutomationSIPS 10/20 Integrated Sample Introduction and Dilution System
Software PlatformSpectrAA Method Development Suite
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginMalaysia
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelAA DUO
Instrument TypeFlame and Graphite Furnace AAS
Optical SystemDual-Beam
Monochromator TypeCustom High-Resolution Echelle Grating
DetectorPhotomultiplier Tube (PMT)
Background CorrectionDeuterium Lamp + Zeeman Effect
Linear Dynamic RangeSub-ppt to Percent-Level Concentrations
AutomationFully Integrated Dual-Atomizer Control via Agilent Workstation Software
ComplianceDesigned for GLP/GMP environments