Empowering Scientific Discovery

Anton Paar (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginSwitzerland
ManufacturerAnton Paar GmbH
TypeImported Instrument
ModelSTEP x01
Instrument CategoryNanoindentation and Scratch Tester
Indenter Tip MaterialDiamond
Base PlatformModular Mechanical Surface Testing System
Maximum Load CapacityNot specified in input
ComplianceGLP/GMP-ready architecture, ASTM E2546, ISO 14577, ISO 20502, USP <1089> compatible (inferred from platform class)
Vibration IsolationOptional active damping table & acoustic enclosure
MicroscopyDual-view optical microscope (20×–10,000× continuous zoom)
Positioning Accuracy<1 µm over extended scan range
Automation InterfaceIntegrated for factory-floor QC integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginImported
ModelMCR 703 MultiDrive
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range−160 °C to +1000 °C
Frequency Range2 × 10⁻⁸ Hz to 200 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelDMA 1002/1102 Petro
Instrument TypeOscillating U-tube Densimeter
Instrument CategoryPortable
Sample TypeLiquid
Density Range0 g/cm³ to 3 g/cm³
Density Accuracy±0.0001 g/cm³
Temperature Range15 °C to 100 °C (59 °F to 212 °F)
Temperature Accuracy±0.03 °C (from +15 °C to +100 °C)
Density Resolution5 significant digits
Viscosity Range (DMA 1102 only)–0.3 mm²/s to 1000 mm²/s
Viscosity Repeatability±0.2%
Minimum Sample Volume3.5 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP touch screen
Dimensions (L×W×H)365 mm × 265 mm × 180 mm
Weight6.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelPoreMaster
PriceUpon Request
Pore Size Range30 nm – 600 µm
Pressure Range0.01 – 50 MPa
Measurement Accuracy≤ 0.5%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeManufacturer
Origin CategoryImported
ModelCora 5001 Fiber
Instrument TypePortable/Handheld Raman Spectrometer
Spectral Range100–3500 cm⁻¹
Spectral Resolution6–9 cm⁻¹
Spatial Resolution1 µm (lateral), 1 µm (axial)
Minimum Wavenumber100 cm⁻¹
Spectral Reproducibility< 0.5 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginSwitzerland
ManufacturerAnton Paar GmbH
TypeHigh-Temperature Tribological Tester
ModelTHT
Maximum Friction Force20 N
Friction Force Resolution0.03 mN
Maximum Operating Temperature1000 °C
Rotational Speed Range0.3–500 rpm (optional up to 1500 rpm)
Maximum Torque450 N·mm
Compliance StandardsDIN 50324, ASTM G99, ASTM G133
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelCarbo
Product TypeOnline Refractometer-Based CO₂ Sensor
Temperature ControlYes
Digital DisplayYes
Measurement Range0–20 g/L (0–10 vol%)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelUltrapyc Series
Instrument TypeTrue Density Analyzer
Instrument ClassBenchtop Laboratory
Sample TypeSolids (bulk & granular), Powders, Pastes, Slurries, Foams
Density Accuracy≤0.015%
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Temperature Range3–60 °C
Minimum Sample Volume0.1 cm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMCP 4100 / MCP 5100 / MCP 5500
Product TypeAutomated Polarimeter
Temperature ControlPeltier-controlled (10–45 °C)
DisplayHigh-resolution touchscreen interface
Light SourceLong-life LED (325–880 nm, up to 8 selectable wavelengths)
Measurement Range±89.9° optical rotation (OR)
Accuracy±0.003° OR (MCP 4100), ±0.002° OR (MCP 5100), <±0.002° OR (MCP 5500)
Resolution0.0001° OR
Repeatability±0.002° OR (MCP 4100/5100), ±0.001° OR (MCP 5500)
Temperature Accuracy±0.1 °C (MCP 4100/5100), ±0.03 °C (MCP 5500)
Sample Cell Max Length200 mm
ComplianceFully 21 CFR Part 11 compliant, GLP/GMP-ready, USP/EP/ChP-compliant, OIML R 167, ASTM E1254, ICUMSA Method GS4/3-12
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelTPO 5000
Instrument TypeBeer-Specific Analyzer
Application ModeOnline & Laboratory
Measurement Time4 min
Dimensions (L × W × H)515 × 590 × 1120 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelMCR Tribological Tester
Instrument TypeCoefficient of Friction Analyzer
Maximum Friction Force70 N
Friction Force Resolution0.005 N
Maximum Temperature600 °C
Normal Force Range0.1–70 N
Normal Force Resolution0.005 N
Rotational Speed Range10⁻⁶–3000 rpm
Sliding Velocity Range10⁻⁸–3.3 m/s
Torque Range1 nNm–300 mNm
Torque Resolution0.1 nNm
Oscillation Frequency Range10⁻⁷–100 Hz
Angular Amplitude Range1 µrad to ∞
Angular Resolution10 nrad
Minimum In-situ Wear Depth Detection0.65 µm
Electrotribology CapabilityYes (0–4 kV, up to 1 mA)
Temperature Control Range (T-BTP module)−160 °C to +600 °C
Humidity Range5–95% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelDMA 502
Instrument TypeOscillating U-tube Density Meter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids and Low-Viscosity Suspensions
Density Range0 to 3 g/cm³
Density Accuracy±0.001 g/cm³
Density Repeatability±0.0002 g/cm³
Density Resolution0.0001 g/cm³
Temperature Range15–40 °C
Temperature Stability±0.1 °C
Minimum Sample Volume1 mL
Display7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen
Environmental CompensationAutomatic pressure, altitude, and ambient humidity correction
Data Storage5000 measurements
Method Library400 pre-validated methods
Conversion Tables140 built-in (alcohol, sugar, acids, API gravity, etc.)
ComplianceASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
Model SeriesCarboQC, CboxQC, OxyQC (At-line Configuration)
Measurement Time2–3 min per sample
Dimensions (L × W × H)258 mm × 201 mm × 170 mm
Weight2.6 kg
Data Storage CapacityUp to 500 measurement datasets
Sample Volume150 mL
CO₂ Range0–12 g/L (0–6 vol%) at 30 °C
Dissolved O₂ Range0–4 ppm
Temperature Range−3 °C to 30 °C
Pressure Range0–10 bar
CO₂ Repeatability (s.d.)±0.005 vol%
O₂ Repeatability (s.d.)±2 ppb
O₂ Response Time (t₉₈%)20 s at 25 °C
Pressure Accuracy±0.01 bar
CO₂ Accuracy (s.d.)±0.05 vol%
O₂ Accuracy (s.d.)±4 ppb
Power SupplyAC 100–240 V, 50/60 Hz
Interfaces1 × USB (PC), 1 × RS-232 (printer or AP-SoftPrint)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
Product TypePortable/Desktop Raman Spectrometer
ModelCora 5001
Spectral Range100–3500 cm⁻¹
Spectral Resolution6–9 cm⁻¹
Spatial Resolution1 µm (lateral), 1 µm (axial)
Minimum Wavenumber100 cm⁻¹
Spectral Reproducibility< 0.5 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
Product TypePortable/Handheld Raman Spectrometer
ModelCora 100
Spectral Range400–2300 cm⁻¹
Spectral Resolution<10 cm⁻¹
Spatial Resolution<1 mm
Laser Wavelength785 nm
Laser Power at Sample>215 mW
DetectorLinear CCD Array
DisplayTransflective TFT with LED Backlight
Operating Temperature−20 °C to +40 °C
IP RatingIP67
Dimensions15.8 cm × 10.1 cm × 2.9 cm
Weight650 g
Battery LifeUp to 60 scans per charge
Data FormatText (.txt)
ConnectivityUSB 2.0
OSEmbedded Linux
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginShanghai, China
ManufacturerAnton Paar (Shanghai) Co., Ltd.
Product TypeDomestic Manufacturing
ModelMultiwave 5001 CN
Cavity ClassIndustrial-Grade
Sample Capacity96 samples per batch
Microwave SourceDual Magnetron
Max Temperature300 °C
Temperature Measurement Accuracy±0.1 °C
Temperature Control Stability±1 °C
Temperature Uniformity±1 °C
Max Pressure100 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
TypeImported Instrument
ModelNST³
Instrument CategoryNanoindentation and Scratch Tester
Maximum Indentation Depth1 µm
Load Resolution0.01 µN
Displacement Range600 µm
Maximum Friction Force1 N
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelNova 600BET / 800BET / 600 / 800
Instrument TypeSpecific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations4
Specific Surface Area Range≥ 0.01 m²/g (no upper limit)
Pressure Range1×10⁻⁴ to 0.999 P/P₀
Supported Theoretical ModelsBET, Langmuir, t-plot, DFT (NLDFT/QSDFT), BJH, DH, DR, HK, SF
Repeatability< 2%
Operating Temperature15–35 °C
Absolute Pressure Resolution1.2×10⁻⁴ Torr
Relative Pressure Resolution1.5×10⁻⁷ P/P₀
Pore Diameter Range0.35–500 nm (0.35–1.1 nm with CO₂ at 273 K)
Minimum Detectable Pore Volume1.2×10⁻⁸ cm³
Integrated Degassing Stations4 (programmable, up to 425 °C)
Dewar Capacity2 L (up to 40 h operation)
Dimensions (D×W×H)44 × 63 × 84 cm
Weight63 kg
Power SupplyAC 100–240 V, 50/60 Hz, max. 345 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
ModelSmartPave
Instrument TypeRotational Rheometer
Sample Viscosity RangeHigh-Viscosity
Sample StateLiquid
Bearing TypeAir Bearing
Temperature Range−160 °C to +1000 °C
Minimum Rotational Speed0 rpm
Frequency Range10⁻⁷ to 1256 rad/s
Maximum Rotational Speed3000 rpm
Maximum Torque215 mNm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelL-Cor Series
Liquid Mass Flow Accuracy±0.1% or ±0.2% (depending on model and operating conditions)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelLovis 2001
Instrument TypeFixed-Position Falling-Ball Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.2 to 10,000 mPa·s
Temperature Range5 °C to 100 °C (41 °F to 212 °F)
Temperature Resolution0.005 °C
Temperature Accuracy±0.02 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ManufacturerAnton Paar GmbH
Instrument TypeSingle-Mode Microwave Synthesizer
Temperature Range0–300 °C
Pressure Range0–30 bar
Microwave Power850 W
Magnetron Frequency2.45 GHz
Stirring MechanismMagnetic Stirring
Reaction Volume30 mL
Coupling InterfaceFiber-Optic Raman Probe (Borosilicate-Glass Compatible)
Real-Time MonitoringTime-Resolved In Situ Raman Acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelPiezo Sample Stage 100 μm × 100 μm
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginGermany
ManufacturerAnton Paar GmbH
TypeImported Instrument
ModelTAG 300/500
Detection MethodClosed-Cup (TAG)
Operation ModeFully Automatic
Sample Temperature Range−35 °C to +130 °C
Ignition SourceCeramic-Coated Electric Igniter
Compliant StandardsASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523
Show next