BrandSabio
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelModel 6020
PriceUpon Request
Measurement PrinciplePulsed UV Fluorescence (PUVF)
Range0–50 ppb to 0–20 ppm (user-selectable)
Detection Limit< 0.4 ppb
Noise< 0.2 ppb
Zero Drift< 0.5 ppb/24 hr
Accuracy< 1% Full Scale
Sample Flow Rate0.4–0.8 L/min
Operating Temperature5–40 °C
Power Consumption200 W
Dimensions (H×W×D)133 × 432 × 571.5 mm
Weight11.3 kg
DisplayHigh-resolution color TFT LCD with touchscreen support
Communication InterfacesEthernet (TCP/IP), USB 2.0, RS-232/485
Analog I/O4 configurable voltage channels (0.1 V, 1 V, 2 V, 5 V, 10 V output ranges)
Digital I/O8 standard TTL-compatible channels
Data LoggingInternal non-volatile memory with timestamped records
ComplianceEPA Reference Method EQOA-0808-191 (equivalent to EPA Method 40 CFR Part 53, Class I)
SoftwareMenu-driven embedded OS with diagnostic suite, barcode-enabled time-series visualization, Modbus RTU/TCP support
Environmental CompensationAutomatic temperature and barometric pressure correction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSilcoTek
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported
ModelSilcoNert-2000
PricingUpon Request
Coating MaterialHydrogenated Amorphous Silicon with Surface Alkylation
Deposition MethodThermal Chemical Vapor Deposition (Non-Plasma)
Max Operating Temperature450°C (inert), 400°C (oxidizing)
Substrate CompatibilityStainless Steel Alloys, Ceramics, Glass, Titanium, Specialty Metals
Max Dimension78 in (198 cm)
Geometry FlexibilityFull 3D Conformality
Thickness Range100–500 nm
Contact Angle (Hydrophobicity)≥65°
pH Stability Range0–8
Patent NumbersUS 6,444,326 & US 6,511,760
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
ModelModel 6050
Detection PrincipleNon-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC)
Measurement Range0–200 ppm (user-selectable)
Resolution0.01 ppm
Unitsppm, ppb
Display7-inch high-resolution color TFT LCD (touch-enabled)
Communication InterfacesEthernet (TCP/IP), USB 2.0 (front-panel & rear), RS-232/485
Analog I/O4-channel configurable voltage/current inputs & outputs
Digital I/O8-channel opto-isolated inputs/outputs
Environmental CompensationAutomatic temperature and barometric pressure compensation
Data LoggingInternal non-volatile memory (≥30 days at 1-min intervals)
ComplianceMeets EPA Method 40 CFR Part 53 reference equivalent performance criteria for CO analyzers
SoftwareEmbedded menu-driven firmware with diagnostic suite, barcode-enabled time-series visualization, and remote configuration via web interface