Empowering Scientific Discovery

Beijing Minnick Analytical Instrument & Equipment Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelValco
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelMTGA6002 Online
PricingAvailable Upon Request
Detector CompatibilityPDHID, PDPID, PDECD, FID, Micro-TCD, RGD
Detection ModePulsed Discharge
Minimum Detectable Concentration1 ppb (for most analytes)
Maximum Detector Configuration4 simultaneous detectors
Communication Interfaces4–20 mA, OPC UA, Profibus DP, Ethernet TCP/IP
Automation LevelFully Automated, Remote Operation Capable
Design ArchitectureModular, User-Configurable
Application ScopeTrace Impurity Analysis in High-Purity Gases, Electronic Specialty Gases, Food-Grade Gas QC, Remote Toxic Gas Monitoring
Hazardous Area SuitabilityCompatible with Third-Party ATEX/IECEx-Certified Detectors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSilcoTek
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelSilcoNert2000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMinik
ModelMS210
OriginBeijing, China
CategoryOther Chromatography Instruments
ApplicationPre-analytical vaporization of liquid hydrocarbons for GC and coulometric Karl Fischer analysis
ComplianceGB/T 3727–2003, GB/T 6023–2008
Liquid Inlet Pressure0.69–2.75 MPa
Output Flow Rate0–5 L/min (adjustable)
Vaporization Temperature RangeUp to 230 °C
Heating & Jacket Temperature Control RangeAmbient +5 °C to 230 °C
Temperature Control Accuracy±0.1 °C
Mass Flow Control Range0–100 mL/min
Flow Resolution0.1 mL/min
Sample IntroductionLiquid or gas phase
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelMS200S
PricingAvailable Upon Request
Liquid Sample Inlet Pressure Range0.69–2.75 MPa
Gas Sample Inlet Pressure Range0.69–2.07 MPa
Temperature Control Range (Heating & Trace Heating)Ambient +5°C to 230°C
Temperature Stability±0.1°C
Carrier Gas Flow Rate0–100 mL/min
Flow Resolution0.1 mL/min
Operating Ambient Temperature−18°C to +65°C
Surface PassivationSilcoTek® SilcoNert®-treated Stainless Steel Tubing
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0