Add to compare
BrandSouthland
OriginUSA
ModelMOMD480, MOMD525
Measurement PrincipleElectrochemical (Galvanic Cell)
Range Options0–1%/5%/10%/25%/100% (MOMD480)
Accuracy±1% FS
DisplayBacklit Color LCD
Enclosure RatingIP66 / NEMA 4X
OutputDual Adjustable Relay Alarms (MOMD525)
Operating EnvironmentInert, N₂, H₂, CO₂-containing, or mixed gas matrices
ComplianceCE, Class I, Div. 1, Groups B, C, D (MOMD625 variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelMY501
Measurement PrinciplePotentiometric Electrochemical (Fuel Cell)
Range Options0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1 %, 0–25 % O₂
Accuracy≤1 % FS (for 0.00–10 ppm range)
Repeatability≤±1 % FS
Response Time (t₉₀)≤30 s
Resolution0.1 ppm
Sample Flow Rate1000 mL/min
Inlet Pressure0.05–0.1 MPa
Output Signals4–20 mA / 0–1 V / 0–10 V DC (selectable)
Operating Temperature–5 °C to +45 °C
Relative Humidity≤90 % RH (non-condensing)
Sensor Lifetime24 months (at 25 °C, 1 atm, avg. [O₂] < 1000 ppm)
Power SupplyDC 12 V
Dimensions (W×H×D)212 × 290 × 194 mm
Weight~2 kg
Enclosure Fitting1/8″ OD compression fitting
Calibration GasN₂-based standard with 80 % of full-scale O₂ concentration
ComplianceDesigned for industrial process monitoring per IEC 61000-6-2/6-4 EMI immunity & emission standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelModel 6020
PriceUpon Request
Measurement PrinciplePulsed UV Fluorescence (PUVF)
Range0–50 ppb to 0–20 ppm (user-selectable)
Detection Limit< 0.4 ppb
Noise< 0.2 ppb
Zero Drift< 0.5 ppb/24 hr
Accuracy< 1% Full Scale
Sample Flow Rate0.4–0.8 L/min
Operating Temperature5–40 °C
Power Consumption200 W
Dimensions (H×W×D)133 × 432 × 571.5 mm
Weight11.3 kg
DisplayHigh-resolution color TFT LCD with touchscreen support
Communication InterfacesEthernet (TCP/IP), USB 2.0, RS-232/485
Analog I/O4 configurable voltage channels (0.1 V, 1 V, 2 V, 5 V, 10 V output ranges)
Digital I/O8 standard TTL-compatible channels
Data LoggingInternal non-volatile memory with timestamped records
ComplianceEPA Reference Method EQOA-0808-191 (equivalent to EPA Method 40 CFR Part 53, Class I)
SoftwareMenu-driven embedded OS with diagnostic suite, barcode-enabled time-series visualization, Modbus RTU/TCP support
Environmental CompensationAutomatic temperature and barometric pressure correction
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSilcoTek
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported
ModelSilcoNert-2000
PricingUpon Request
Coating MaterialHydrogenated Amorphous Silicon with Surface Alkylation
Deposition MethodThermal Chemical Vapor Deposition (Non-Plasma)
Max Operating Temperature450°C (inert), 400°C (oxidizing)
Substrate CompatibilityStainless Steel Alloys, Ceramics, Glass, Titanium, Specialty Metals
Max Dimension78 in (198 cm)
Geometry FlexibilityFull 3D Conformality
Thickness Range100–500 nm
Contact Angle (Hydrophobicity)≥65°
pH Stability Range0–8
Patent NumbersUS 6,444,326 & US 6,511,760
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
ModelModel 6050
Detection PrincipleNon-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC)
Measurement Range0–200 ppm (user-selectable)
Resolution0.01 ppm
Unitsppm, ppb
Display7-inch high-resolution color TFT LCD (touch-enabled)
Communication InterfacesEthernet (TCP/IP), USB 2.0 (front-panel & rear), RS-232/485
Analog I/O4-channel configurable voltage/current inputs & outputs
Digital I/O8-channel opto-isolated inputs/outputs
Environmental CompensationAutomatic temperature and barometric pressure compensation
Data LoggingInternal non-volatile memory (≥30 days at 1-min intervals)
ComplianceMeets EPA Method 40 CFR Part 53 reference equivalent performance criteria for CO analyzers
SoftwareEmbedded menu-driven firmware with diagnostic suite, barcode-enabled time-series visualization, and remote configuration via web interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSouthland
OriginUSA
ModelH2S-725
Explosion ProtectionClass 1, Div 1, Groups B, C, D
Measurement Range0–200 ppm or 0–2000 ppm H₂S
Accuracy±2% FS
Output4–20 mA
Power Supply12–24 V DC
Current Draw50 mA
Response Time (T90)<60 s
Sample Flow Rate0.25–5.0 SCFH
Inlet Pressure0.1–50 PSIG
Operating Temperature0–50 °C
Enclosure Dimensions15.25" × 12.5" × 5.25"
Weight18.5 lb
Sensor TypeElectrochemical fuel cell (current-based)
Calibration IntervalRecommended every 1–3 months
Warranty12 months (sensor and electronics)
Gas Connection1/4" Swagelok
Interference ResponseMethyl mercaptan (40%), SO₂ (18%)
Optional FeaturesHeated enclosure, custom range configuration, sampling system integration, bidirectional RS485 communication