Empowering Scientific Discovery

Beijing Minnick Analytical Instrument & Equipment Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelMY702-4/6
Maximum Flash Vaporization Temperature230 °C
Heating & Jacket Temperature RangeAmbient +5 °C to 230 °C
Temperature Control Accuracy±0.1 °C
Sample Ports4 or 6 positions + 1 purge gas channel
Inlet FittingM14×1.5 internal thread quick-connect
Tubing1/16″ SilcoTek-passivated stainless steel
Power Supply220 V, 50 Hz
Power Consumption100 W
Dimensions (4-port)400 × 255 × 300 mm
Net Weight20 kg
ComplianceDesigned for ASTM D6667, ASTM D7164, ISO 8570, and USP <621> gas chromatographic workflows requiring trace sulfur and oxygenate analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
ModelMQY301
OriginBeijing, China
Configuration5-channel gas bag sampler + 1-channel liquid flash-vaporization inlet
Dimensions (W×D×H)400 × 255 × 300 mm
Net Weight15 kg
Power Supply220 V, 50 Hz
Power Consumption300 W
Maximum Flash-Vaporization & Jacket Temperature230 °C
Temperature Control Accuracy±0.1 °C
Liquid Injection Pressure Range100–400 psi
Sample Transfer LinePassivated stainless steel
Interface OptionsAUX trigger, touch control, GC instrument control port
Inlet ValveIntegrated 6-position gas sampling valve with quantitative loop
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelMG220
PricingUpon Request
Operating Pressure Range0.7–4 MPa
Drive GasDry Air or Inert Gas (0.4 MPa)
Auxiliary Gas Flow Rate50–200 mL/min
Internal Tubing1/16″ SilcoTek-Passivated Stainless Steel
Valve Core Volume Options0.06–2 μL (Standard: 1 μL)
Dead VolumeMinimized (<10 μL typical)
RepeatabilityRSD < 2% (n ≥ 6)
Dimensions (W×D×H)130 mm × 200 mm × 200 mm
MountingDirect installation above GC inlet port
Weight~1.5 kg
Surface TreatmentSilcoTek® SilcoNert® 2000 inert coating applied to entire fluid path
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEMCEE
OriginUSA
Model1140
Standard ComplianceASTM D3948, SH/T 0616–1995
Test PrincipleGravimetric optical transmittance measurement of water separation kinetics in jet fuel
Accessories IncludedPrecision glass syringes, calibrated transfer pipettes, test cuvettes, reference standards
ConfigurationPortable benchtop unit with integrated timer and optical sensor module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrace
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGRACE 923
PricingAvailable Upon Request
Certified StandardCompliant with GB/T 11132 and ASTM D1319
Average Pore Diameter32 Å
Pore Size DistributionNarrow
Packaging500 g per bottle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMNKSAG0609
PricingUpon Request
Diameter47 mm
Pore Size0.8 µm
Pack Size100 per Box
ComplianceSH/T 0175–2004, ASTM D2274
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelMS200
Sample Inlet Pressure Range (Liquid)0.69–2.75 MPa
Sample Inlet Pressure Range (Gas)≤2.07 MPa
Vaporization Temperature Control RangeAmbient to 150 °C
Transfer Line Heating RangeAmbient to 150 °C
Operating Ambient Temperature–18 °C to +65 °C
Power Supply220 VAC, 50 Hz, max. 3.0 A
Dimensions (H×W×D)230 mm × 190 mm × 350 mm
ComplianceDesigned for integration with GC and GC-MS systems in petroleum refining and hydrocarbon analysis labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEMCEE
OriginUSA
ModelModel 1152
Measurement Range0–1999 pS/m
Resolution1 pS/m
Accuracy±2% of reading + 1 pS/m
Display3-digit LCD, digit height 0.27 cm
Power Supply3 × alkaline batteries (6 V total)
Operating Temperature0–75 °C
ProbeRemovable stainless-steel, intrinsically safe
Safety CertificationsUL, CSA (Canada), LCIE
CalibrationInternal reference, field-adjustable via two-button interface ("M" for Measure, "C" for Calibrate)
Overrange IndicationLeading "1" on display
EnclosureSolvent-resistant molded polymer housing
GroundingBanana jack terminal
Battery Low/Overrange AlertsVisual indicators
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEMCEE
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelModel 1140
Unit PriceUSD 1.00
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEMCEE
OriginUSA
ModelJFTOT MARKIII
ComplianceASTM D3241, GB/T 9169
ConsumablesHeating Rod & MNKJG0605 Filter Assembly
Supply ChannelAuthorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUOP
OriginUSA
PackagingAmber Glass Bottle
Storage RequirementAmbient, Under Nitrogen Atmosphere
ComplianceASTM D1319-22, GB/T 11132-2022
ApplicationFluorescent Indicator Adsorption Chromatography of Liquid Petroleum Hydrocarbons
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEMCEE
OriginUSA
Model1140
ComplianceASTM D3948, SH/T 0616-1995
ApplicationAviation Turbine Fuel (Jet A/Jet A-1) Water Separation Performance Testing