BrandSabio
OriginBeijing, China
Model4010L
Diluent Flow Range0–10 SLM (optional up to 20 SLM)
Source Gas Flow Range0–100 SCCM / 0–10,000 SCCM
Flow Accuracy≤ ±1% FS
Flow Repeatability≤ ±0.15% FS
Linearity≤ ±0.5% FS
Inlet Pressure20–35 PSIG
Ozone Generator Output0.05–1.5 ppm at 5 SLPM
Ozone Generator Accuracy±1% of setpoint or ±2 ppb at 5 SLPM
UV Absorption Photometer Range0–0.5 / 1.0 / 2.0 ppm
Photometer Zero Drift< ±1 ppb per 24 h (or 30 days)
Photometer Flow Rate1.0 LPM
Dilution Furnace Temperature RangeAmbient +5 °C to 65 °C
Temperature Stability< ±0.1 °C
Calibration Programs20 user-configurable, time- and event-driven (7-day cycle support)
Input/Output24-bit digital I/O, 2× serial ports (RS232 standard), parallel printer port, external keyboard interface, air source control port
DisplayHigh-brightness color LCD
Keypad55-key membrane panel
Gas Ports4 source gas inlets, 1 purge inlet, 1 diluent inlet, 5 calibrated outputs, 1 exhaust port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEnvironics
OriginUSA
Model4000 Series
Dilution RatioUp to 10,000:1
Concentration Range% to ppb
Flow Accuracy±1.0% of setpoint (concentration & flow)
Flow Repeatability±0.05%
Warm-up Time30 min
Gas Connection1/4" Swagelok® or compatible
Operating Pressure10–75 psig (0.67–5.04 bar)
UHP Leak Rate≤1×10⁻⁹ atm·cm³/sec He
Humidity Range (optional)0–95% RH (±5% accuracy, NIST-traceable)
HeatingOptional heated gas pathways (temperature-controlled)
Surface TreatmentOptional silanized stainless-steel tubing
Purge PathwayIntegrated electromagnetic valve purge system
Permeation OvenOptional multi-zone permeation furnace with dual-permeation-tube capacity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Model4010
Flow Accuracy±1.0% of Full Scale
Flow Repeatability±0.15% of Full Scale
Flow Linearity±0.5% of Full Scale
Diluent MFC Range0–10 SLPM (optional 0–20 SLPM)
Source MFC Range0–100 SCCM (optional 0–50 / 0–200 / 0–500 SCCM / 0–1 SLM)
Input Pressure20–35 psig
Ozone Output Range0.05–1.5 ppm at 5 SLPM (extendable to 0.05–1.0 ppm at 15 SLPM)
Ozone Accuracy±2% of setpoint or ±3 ppb at 5 SLPM
Ozone Flow Control Precision±1 SCCM at 100 SCCM
95% Setpoint Response Time<60 s
Wetted Materials316 Stainless Steel, PTFE, PEEK, Halar
SealsViton, Kalrez
Optional Internal Permeation Oven94 cm³ Volume, 13.2 cm Length, 3.02 cm ID, Temperature Stability: ±0.1°C (setpoint +60°C above ambient), Preheat Time: <30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEnvironics
OriginUSA
Model4040
Dilution RatioUp to 10,000:1
Flow Accuracy±1.0% of setpoint
Concentration Accuracy±1.0% of setpoint
Flow Repeatability±0.05%
Dimensions (Portable)43.18 cm × 17.78 cm × 38.1 cm
Weight8.2 kg (2-MFC), 10.4 kg (4-MFC), 15.9 kg (8-MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginBeijing, China
ModelSabio2010
Diluent Flow Range0–10 SLM (up to 20 SLM optional)
Source Gas Flow Range0–100 SCCM (up to 2 SLM optional)
Flow Accuracy<1% FS
Flow Repeatability±0.15% FS
Linearity±0.5% FS
Inlet Pressure12–35 PSIG
Operating Temperature5–40°C
Dimensions156 mm (H) × 364 mm (W) × 316 mm (D)
Weight8.6 kg
Power Supply98–264 VAC, 100 VA, 50/60 Hz
Communication InterfacesRS-232, Ethernet (TCP/IP optional)
Digital I/O8-bit TTL/contact-triggered
Calibration Paths20 preconfigured, each supporting up to 20 linear points
Gas Configuration1 diluent + 20 source gases
Output Ports3 calibrated outputs + 1 exhaust port (1 permeation port optional)
Input Interface42-key membrane keypad or external keyboard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
ModelVICI Cheminert M
Flow Range (M10)10 nL – 10 mL
Flow Range (M50)50 µL – 50 mL
Pump TypeSyringe-free, bidirectional, anodized displacement pump
Valve ConfigurationMulti-position fluid path selection valve
Program StorageUp to 100 user-defined methods
Physical DesignCompact benchtop footprint
Compliance ContextDesigned for GLP-compliant liquid handling in regulated analytical laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 2010
PricingUpon Request
Diluent Mass Flow Range0–10 SLM (optional up to 20 SLM)
Source Gas Mass Flow Range0–100 SCCM (optional up to 2 SLM)
Flow Accuracy≤1% FS
Flow Repeatability≤±0.15% FS
Linearity≤±0.5% FS
Response Time<60 s
Control InterfacesKeypad, Keyboard, RS-232 Serial, USB, Ethernet
Predefined Calibration Paths20 factory-configured flow paths, each supporting up to 20 linear calibration points
Supported Calibration TypesDiluent gas, Ozone (O₃), Gas Phase Titration (GPT)
Temperature Control SystemMicroprocessor-based proportional PID controller
Temperature SensorPlatinum RTD (Pt100)
Heating Zone DimensionsInternal Diameter 3.09 cm, Length 12.7 cm
Temperature RangeAmbient +2 °C to 65 °C
Front Panel IntegrationAdjustable pressure regulator, analog pressure gauge, digital temperature controller, Teflon-lined dilution furnace inlet