Empowering Scientific Discovery

Beijing Minnick Analytical Instrument & Equipment Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelM8880
Instrument TypeLaboratory Gas Chromatograph
ApplicationHigh-Purity Gas Analysis
Carrier Gas OptionsSingle selectable gas (e.g., He, H₂, or Ar)
Dual-Detector ConfigurationPDHID + TCD
Independent Temperature Zones8
Oven Programmed Ramps20-step
Back-Flush & Heart-Cut CapabilityIntegrated
Detection Limits (v/v)PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L
TCD — O₂49 µL/L, N₂: 70 µL/L
PDHID SpecificationsPulsed Discharge Helium Ionization Detector
TCD SpecificationsBaseline Noise ≤ 20 µV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8810
Instrument TypeOnline Gas Chromatograph
Application FocusHigh-Purity Gas Analysis
Detector ConfigurationUp to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD)
Communication InterfaceEthernet-enabled Industrial Bus Architecture
Compliance ContextDesigned for GLP/GMP-aligned environments with audit-ready data handling capabilities
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor & System Integrator
Regional ClassificationDomestic (China-Made)
ModelGC7890B
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelM8880
Instrument TypeLaboratory Gas Chromatograph
Application DomainHigh-Purity Gas Analysis
Carrier Gas OptionsSingle selectable gas (e.g., He, H₂, or Ar)
Detector ConfigurationDual-detector, multi-column parallel architecture
Temperature Control8 independent zones, 20-step programmable ramping
Advanced FunctionalityBuilt-in back-flush module enabling heart-cutting and column switching
Data SystemDedicated GC workstation with automated flammability triangle (CH₄–O₂–N₂) explosion hazard assessment
Detection Limits (v/v)PDHID — H₂ (0.06 µL/L), CH₄ (0.08 µL/L), CO (0.08 µL/L), C₂H₆ (0.01 µL/L), CO₂ (0.09 µL/L), C₂H₄ (0.01 µL/L), C₂H₂ (0.01 µL/L), C₃H₈ (0.01 µL/L), H₂S (0.01 µL/L), C₃H₆ (0.01 µL/L), SO₂ (0.23 µL/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8800 Series
Instrument TypeOnline Gas Chromatograph
Detector ConfigurabilityUp to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID)
Injection OptionsPacked column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector
Oven Temperature Range+4 °C above ambient to 450 °C (1 °C increment)
Oven Temperature Stability±0.1 °C at 200 °C
Oven Programmable Stages16 temperature ramps
Cooling Rate260 °C to 50 °C in ~6 min
Temperature Zones8 independently controlled zones
Carrier Gas ControlElectronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm
Display5.7-inch color TFT touchscreen
Data InterfaceEthernet (IEEE 802.3), PC-controlled operation or standalone mode
Remote CapabilityNetwork-enabled remote monitoring, unattended operation, distributed acquisition, centralized control
Multidimensional GC SupportCenter-cutting and valve-switching configurations enabled
SoftwareMethod-driven acquisition with full parameter storage and recall
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
ModelGC8800-II
OriginBeijing, China
Instrument TypeLaboratory Gas Chromatograph
Application FocusHigh-Purity Gas Analysis
Control InterfaceIEEE 802.3 Ethernet
EPC ModuleIntegrated Electronic Pressure Control (EPC) and Electronic Flow Control (EFC)
Autosampler CompatibilityDual-tower 24-position liquid autosampler
Optional Gas AutosamplingMNK Cylinder & Gas-Phase Autosampler
Ancillary Module SupportMNK Flash Vaporizer for LPG, Butadiene, and 1-Butene analysis
Data SystemMulti-instrument data aggregation
Regulatory AlignmentDesigned to support GLP-compliant workflows and 21 CFR Part 11–ready audit trail configuration (when paired with validated software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Model Variants110, 310, 410, 8610C, 8610D
ConfigurationBenchtop or Portable Chassis Options
DetectorsFID, TCD, SCD, PID (User-Selectable)
ComplianceASTM D1945, D1946, D3588, ISO 8573-5, USP <467>, EPA Method TO-14A/TO-15
Data SystemStandalone PC-Based Acquisition & Processing Software (No Dedicated Terminal Required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
Model23443
OriginUSA
TypePortable Thermal Conductivity-Based Leak Detector
Detectable GasesHe, N₂, Ar, CO₂, H₂
Power SourceRechargeable Ni-MH Battery (6 h typical runtime)
Operating Temperature0–48 °C
Relative Humidity0–97 % RH
CertificationsCE, RoHS, WEEE
ComplianceCompliant with EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS), and Japan’s JIS C 0950 (RoHS-equivalent)
Enclosure RatingIP54 (dust-protected, water-splashing resistant)
Probe InterfaceStandard 1/8" Swagelok-compatible stainless steel insertion probe
Auto-ShutdownEnabled after 5 min inactivity
Charging AdapterUniversal AC input (100–240 VAC, 50/60 Hz)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelValco
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelMTGA6002 Online
PricingAvailable Upon Request
Detector CompatibilityPDHID, PDPID, PDECD, FID, Micro-TCD, RGD
Detection ModePulsed Discharge
Minimum Detectable Concentration1 ppb (for most analytes)
Maximum Detector Configuration4 simultaneous detectors
Communication Interfaces4–20 mA, OPC UA, Profibus DP, Ethernet TCP/IP
Automation LevelFully Automated, Remote Operation Capable
Design ArchitectureModular, User-Configurable
Application ScopeTrace Impurity Analysis in High-Purity Gases, Electronic Specialty Gases, Food-Grade Gas QC, Remote Toxic Gas Monitoring
Hazardous Area SuitabilityCompatible with Third-Party ATEX/IECEx-Certified Detectors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC-8810
Instrument TypeLaboratory Gas Chromatograph
Application DomainCoal Industry Specific
Detection LimitsPermanent Gases (N₂, CO₂, O₂) < 10 ppm
Analysis Time≤ 2 min (including backflush)
Modular ConfigurationUp to 4 independent GC channels
Detector TechnologyNEMS-based silicon micro-TCD
Flow ControlElectronic Pressure Control (EPC) per channel
Temperature ControlIndependent oven and column-zone heating per module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSilcoTek
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelSilcoNert2000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8800
Instrument TypeOnline Gas Chromatograph
Application DomainUltra-High-Purity (UHP) Gas Impurity Analysis
Detector TypePulsed Discharge Helium Ionization Detector (PDHID)
Carrier GasUltra-High-Purity Helium (≥99.999%, purified to ≤10 ppb total impurities)
Baseline Noise≤0.1 mV
Baseline Drift≤0.5 mV/30 min
Detection Limit≤1.0 × 10⁻¹⁰ g/mL
Gas Control OptionsManual Valving & Electronic Pressure Control (EPC)
Data TransmissionEthernet-enabled Remote Monitoring & Unattended Operation
Regulatory Compliance SupportASTM D7622, ISO 8573-8, SEMI F57, IEC 60400, USP <621>, FDA 21 CFR Part 11-ready audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
OriginUSA
Product LinesAllure® C18, Allure® Basix, Allure® PFP Propyl, Allure® Biphenyl, Ultra C18, Ultra Aqueous C18, Ultra IBD, Kromasil® C18, Viva Wide Pore C18, Pinnacle™ II C18, Pinnacle™ DB C18
Column Dimensions50 mm, 150 mm, 250 mm (length)
Particle Sizes3 µm & 5 µm
Catalog Numberse.g., 9214352-712, 9414565-712, 9178575-712, etc.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8800 (Dual-Detector)
Instrument TypeLaboratory Gas Chromatograph
Primary ApplicationHigh-Purity Gas Analysis
Detector ConfigurationPulsed Discharge Helium Ionization Detector (PDHID) + Secondary Detector (e.g., TCD or FID)
Carrier GasUltra-High-Purity Helium Only
Linear Range10⁵
Detection LimitSub-ppb for H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₆, C₂H₄, C₂H₂, H₂S, C₃H₈, C₃H₆
Regulatory ComplianceDesigned to support GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
ModelPGC-8800
TypeOnline Gas Chromatograph
Primary ApplicationHigh-Purity Gas Analysis
Detection PrinciplePulsed Discharge Helium Ionization Detection (PDHID)
Detection Limits (PDHID)H₂ (5 ppb), He (5 ppb), O₂ (10 ppb), N₂ (10 ppb), Ar (10 ppb), Ne (500 ppb), CO (25 ppb), CO₂ (5 ppb), CH₄ (5 ppb), CF₄ (10 ppb), C₂F₆ (20 ppb), SO₂F₂ (20 ppb), C₃F₈ (20 ppb)
Complementary DetectorsTCD, FID
Sample PhaseGaseous
Operating ModeContinuous Unattended Online Monitoring
OriginBeijing, China
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelPGC-8800
Instrument TypeOnline Gas Chromatograph
Application FieldHigh-Purity Gas Analysis
DetectorsPDHID, TCD, FID
Detection Limits (ppb)H₂ (5), He (5), O₂ (10), N₂ (10), Ar (10), Ne (10), CO (25), CO₂ (5), CH₄ (5), CF₄ (10), C₂F₆ (20), SO₂ (20), F₂ (20), C₃F₈ (20)
Temperature Control Accuracy±0.01°C
Baseline Noise≤0.1 mV
Analog Outputs5–12 channels of 4–20 mA
Communication Interfaces1× Ethernet, 1× RS-232 (expandable)
Display10.1″ high-resolution capacitive touchscreen
EnclosureStandard 5U rack-mount chassis (482 × 432 × 222 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMinik
ModelMS210
OriginBeijing, China
CategoryOther Chromatography Instruments
ApplicationPre-analytical vaporization of liquid hydrocarbons for GC and coulometric Karl Fischer analysis
ComplianceGB/T 3727–2003, GB/T 6023–2008
Liquid Inlet Pressure0.69–2.75 MPa
Output Flow Rate0–5 L/min (adjustable)
Vaporization Temperature RangeUp to 230 °C
Heating & Jacket Temperature Control RangeAmbient +5 °C to 230 °C
Temperature Control Accuracy±0.1 °C
Mass Flow Control Range0–100 mL/min
Flow Resolution0.1 mL/min
Sample IntroductionLiquid or gas phase
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSRI
Price RangeUSD 14,000 – 42,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelMS200S
PricingAvailable Upon Request
Liquid Sample Inlet Pressure Range0.69–2.75 MPa
Gas Sample Inlet Pressure Range0.69–2.07 MPa
Temperature Control Range (Heating & Trace Heating)Ambient +5°C to 230°C
Temperature Stability±0.1°C
Carrier Gas Flow Rate0–100 mL/min
Flow Resolution0.1 mL/min
Operating Ambient Temperature−18°C to +65°C
Surface PassivationSilcoTek® SilcoNert®-treated Stainless Steel Tubing