KeyBrand: Restek
OriginUSA
MaterialElectropolished Stainless Steel (316L)
Valve TypeParker Hannifin Metal-to-Metal Sealed Diaphragm Valve (2/3-turn)
Volume Options1 L, 3 L, 6 L, 15 L
Operating TemperatureUp to 250 °C
Internal Surface TreatmentElectropolishing + Ultrasonic Cleaning + Passivation
Leak IntegrityHelium-leak tested (<1×10⁻⁹ atm·mL/s)
Pressure Rating60 psig / Vacuum Range: –30" Hg
ComplianceEPA TO-14A, TO-15A, ASTM D5466, USP <661>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginBeijing, China
Model4010L
Diluent Flow Range0–10 SLM (optional up to 20 SLM)
Source Gas Flow Range0–100 SCCM / 0–10,000 SCCM
Flow Accuracy≤ ±1% FS
Flow Repeatability≤ ±0.15% FS
Linearity≤ ±0.5% FS
Inlet Pressure20–35 PSIG
Ozone Generator Output0.05–1.5 ppm at 5 SLPM
Ozone Generator Accuracy±1% of setpoint or ±2 ppb at 5 SLPM
UV Absorption Photometer Range0–0.5 / 1.0 / 2.0 ppm
Photometer Zero Drift< ±1 ppb per 24 h (or 30 days)
Photometer Flow Rate1.0 LPM
Dilution Furnace Temperature RangeAmbient +5 °C to 65 °C
Temperature Stability< ±0.1 °C
Calibration Programs20 user-configurable, time- and event-driven (7-day cycle support)
Input/Output24-bit digital I/O, 2× serial ports (RS232 standard), parallel printer port, external keyboard interface, air source control port
DisplayHigh-brightness color LCD
Keypad55-key membrane panel
Gas Ports4 source gas inlets, 1 purge inlet, 1 diluent inlet, 5 calibrated outputs, 1 exhaust port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTO-14 Special GC
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLinde
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model SeriesTO-14A (39-component), TO-14A (43-component), TO-15 (65-component)
CertificationNIST-traceable by gravimetric preparation
Cylinder TypeDisposable aluminum (Pi-labeled or standard 104 L / 110 L)
Pressure1,800 psi
Stabilization Period12 months
Available Concentrations100 ppb or 1 ppm in high-purity nitrogen
Analytical CertificateIncluded with unique serial number and full component assay report
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
ModelModel 230
Temperature Control RangeUp to 100°C
Flow StabilityConstant flow through permeation tube chamber
Dilution Flow RangeWide, enabling linear calibration across multiple concentration levels
ConfigurationBenchtop dynamic gas calibration system with integrated mass flow controllers and temperature-regulated permeation module
Compliance ContextDesigned for traceable calibration per EPA Method TO-15, ASTM D6196, ISO 16017, and USP <1231> for VOC analyzers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelMQ701-16 / MQ701-32 Integrated Solution
PricingAvailable Upon Request
Core ComponentsMQ801 Vacuum Sampling Chamber, MQ701-16/MQ701-32 16-/32-Position Automated Gas Bag Injector, MODEL401 Precision Gas Dilution System
ComplianceDesigned to meet HJ 38–2017 (China EPA Standard for Determination of Total Hydrocarbons, Methane, and NMHC in Stationary Source Exhaust)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
Model6040
PriceUpon Request
Measurement PrincipleChemiluminescence Detection
Range0–50 ppb to 0–20 ppm (user-selectable)
Unitsppm, ppb
DisplayHigh-resolution color TFT LCD
Interface OptionsTouchscreen, front-panel keypad, external keyboard/mouse
Data LoggingInternal non-volatile memory with timestamping
CommunicationEthernet (TCP/IP), USB 2.0 (host & device), RS-232/485
Analog I/O4 channels, configurable voltage output (0.1 V, 1 V, 2 V, 5 V, 10 V)
Digital I/O8 standard TTL-compatible inputs/outputs
Environmental CompensationAutomatic temperature and pressure correction
EPA CertificationRFNA-0418-250
Detection Limit< 0.4 ppb
Noise< 0.2 ppb
Zero Drift< 0.5 ppb/24 hr
Accuracy< 0.5% of full scale
Sample Flow Rate0.4–0.8 L/min
Operating Temperature5–45 °C (EPA-specified range)
Operating Humidity0–90% RH (non-condensing)
Power Requirement200 W, 100–240 VAC, 50/60 Hz
Dimensions (H×W×D)133 × 432 × 571.5 mm
Weight11.3 kg (25 lbs)
ProtocolsModbus RTU/TCP, SCPI-compliant command set
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEnvironics
OriginUSA
Model4000 Series
Dilution RatioUp to 10,000:1
Concentration Range% to ppb
Flow Accuracy±1.0% of setpoint (concentration & flow)
Flow Repeatability±0.05%
Warm-up Time30 min
Gas Connection1/4" Swagelok® or compatible
Operating Pressure10–75 psig (0.67–5.04 bar)
UHP Leak Rate≤1×10⁻⁹ atm·cm³/sec He
Humidity Range (optional)0–95% RH (±5% accuracy, NIST-traceable)
HeatingOptional heated gas pathways (temperature-controlled)
Surface TreatmentOptional silanized stainless-steel tubing
Purge PathwayIntegrated electromagnetic valve purge system
Permeation OvenOptional multi-zone permeation furnace with dual-permeation-tube capacity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 150
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelsMTB100, MQ701-6, MQ801
Pressure Rating1800–5000 psi (DOT-certified)
Bag Volumes0.5 L, 1 L, 3 L, 5 L, 10 L
Bag MaterialPolyvinyl Fluoride (PVF), 0.002" thickness
Valve OptionsPolypropylene or Stainless Steel
Max Operating Temperature204°C
Bag Construction5-layer metallized foil (MNK123557)
Sample CompatibilityCO, CO₂, H₂S, NH₃, SO₂, NOₓ, and other low-molecular-weight gases
Detection Limit Suitabilityppb-level for inert and moderately reactive species
VOC Range LimitationNot recommended for sub-ppm volatile organic compound quantification
Injector Configuration6/16/32-port programmable selection valve
Vacuum SourceDiaphragm pump (zero-contamination design)
Sample LineSilinert®-passivated, heated (anti-condensation)
ControllerVICI high-reliability industrial controller
Power SupplyRechargeable battery (MQ801)
ComplianceDOT 4BA/4BW certified (MTB100), GLP-compatible operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Model4010
Flow Accuracy±1.0% of Full Scale
Flow Repeatability±0.15% of Full Scale
Flow Linearity±0.5% of Full Scale
Diluent MFC Range0–10 SLPM (optional 0–20 SLPM)
Source MFC Range0–100 SCCM (optional 0–50 / 0–200 / 0–500 SCCM / 0–1 SLM)
Input Pressure20–35 psig
Ozone Output Range0.05–1.5 ppm at 5 SLPM (extendable to 0.05–1.0 ppm at 15 SLPM)
Ozone Accuracy±2% of setpoint or ±3 ppb at 5 SLPM
Ozone Flow Control Precision±1 SCCM at 100 SCCM
95% Setpoint Response Time<60 s
Wetted Materials316 Stainless Steel, PTFE, PEEK, Halar
SealsViton, Kalrez
Optional Internal Permeation Oven94 cm³ Volume, 13.2 cm Length, 3.02 cm ID, Temperature Stability: ±0.1°C (setpoint +60°C above ambient), Preheat Time: <30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEnvironics
OriginUSA
Model4040
Dilution RatioUp to 10,000:1
Flow Accuracy±1.0% of setpoint
Concentration Accuracy±1.0% of setpoint
Flow Repeatability±0.05%
Dimensions (Portable)43.18 cm × 17.78 cm × 38.1 cm
Weight8.2 kg (2-MFC), 10.4 kg (4-MFC), 15.9 kg (8-MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelMCY600
Operating Temperature5–45 °C
Sample Gas Pressureup to 20 kPa (gauge)
Sample Flow Rate0.2–1.0 L/min
Power Supply12–24 VDC
Output Signal4–20 mA
Communication InterfaceRS485 (Modbus RTU)
Measurement Ranges0–5%, 0–10%, 0–21%, 0–50%, 0–90%, 90–100%, 0–100% O₂ (v/v)
Linearity Error±2% FS
Stability±2% FS / 7 days
Repeatability±1% FS
Cross-Interference ResistanceNH₃, CO, CO₂, CH₄
Corrosive Gas ToleranceYes (e.g., H₂S)
Sensor TypeThermal-Magnetic Paramagnetic Detection
Vibration ImmunityHigh
Consumable-Free DesignYes
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelParker Balston NG Series
Price RangeUSD 1,400 – 2,800 (FOB)
Analyte ScopeTrace Impurity Analysis in Ultra-High-Purity Gases (He, H₂, N₂, CO₂, O₂, CH₄, H₂O, CO, etc.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginBeijing, China
ModelSabio2010
Diluent Flow Range0–10 SLM (up to 20 SLM optional)
Source Gas Flow Range0–100 SCCM (up to 2 SLM optional)
Flow Accuracy<1% FS
Flow Repeatability±0.15% FS
Linearity±0.5% FS
Inlet Pressure12–35 PSIG
Operating Temperature5–40°C
Dimensions156 mm (H) × 364 mm (W) × 316 mm (D)
Weight8.6 kg
Power Supply98–264 VAC, 100 VA, 50/60 Hz
Communication InterfacesRS-232, Ethernet (TCP/IP optional)
Digital I/O8-bit TTL/contact-triggered
Calibration Paths20 preconfigured, each supporting up to 20 linear points
Gas Configuration1 diluent + 20 source gases
Output Ports3 calibrated outputs + 1 exhaust port (1 permeation port optional)
Input Interface42-key membrane keypad or external keyboard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVICI
OriginUSA
ModelVICI Cheminert M
Flow Range (M10)10 nL – 10 mL
Flow Range (M50)50 µL – 50 mL
Pump TypeSyringe-free, bidirectional, anodized displacement pump
Valve ConfigurationMulti-position fluid path selection valve
Program StorageUp to 100 user-defined methods
Physical DesignCompact benchtop footprint
Compliance ContextDesigned for GLP-compliant liquid handling in regulated analytical laboratories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
OriginUSA
ModelSilcoCan
Capacity Options1 L, 3 L, 6 L, 15 L
Surface TreatmentSiltek®-coated interior and all wetted surfaces
Valve OptionsParker diaphragm valve (standard or Siltek®-treated), with or without integrated pressure gauge
ComplianceDesigned for EPA TO-14A and TO-15 compliance
Application FocusUltra-trace sulfur compound sampling (1–20 ppb)
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Restek
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMNK123521
Vacuum PumpEdwards RV-8
Max Temperature110 °C
Vacuum Level≤50 mTorr in ≤30 min (for 6 L canister)
Capacity12 × 6 L or 24 × 1 L canisters
ComplianceEPA Methods TO-14A & TO-15
Control InterfaceIntegrated touchscreen controller with 10 programmable cleaning cycles
Cold TrapStainless steel vacuum/pressure-rated cold trap
Power Supply220–230 V, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 2010
PricingUpon Request
Diluent Mass Flow Range0–10 SLM (optional up to 20 SLM)
Source Gas Mass Flow Range0–100 SCCM (optional up to 2 SLM)
Flow Accuracy≤1% FS
Flow Repeatability≤±0.15% FS
Linearity≤±0.5% FS
Response Time<60 s
Control InterfacesKeypad, Keyboard, RS-232 Serial, USB, Ethernet
Predefined Calibration Paths20 factory-configured flow paths, each supporting up to 20 linear calibration points
Supported Calibration TypesDiluent gas, Ozone (O₃), Gas Phase Titration (GPT)
Temperature Control SystemMicroprocessor-based proportional PID controller
Temperature SensorPlatinum RTD (Pt100)
Heating Zone DimensionsInternal Diameter 3.09 cm, Length 12.7 cm
Temperature RangeAmbient +2 °C to 65 °C
Front Panel IntegrationAdjustable pressure regulator, analog pressure gauge, digital temperature controller, Teflon-lined dilution furnace inlet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCalifornia Instruments
OriginUSA
Model700
Spectral Resolution0.5 cm⁻¹
Spectral Range305–7500 cm⁻¹
DetectorMCT-A
InterferometerRockSolid™ Cube Corner Retroreflector Design
Sample Cell Temperature50 °C or 191 °C (heated, 316 stainless steel)
Optical Path Length10.2 m
Data Output Rate1 Hz
Response Time<1 s to 5 min (application-dependent)
Detection Rangeppb to % v/v
Sample Flow Rate0.2–5 LPM
Dimensions26.7 × 48.3 × 71.1 cm (H×W×D)
Weight57.6 kg
Environmental Operating Range5–40 °C, <90% RH (non-condensing)
Power Supply230 VAC / 50 Hz
Window MaterialZnSe (standard), optional alternatives available
SealingParafluor O-rings
Inlet/Outlet Fittings3/8″ tubing
Purge Fitting1/4″ Swagelok® compression
Added to wishlistRemoved from wishlist 0
Add to compare
BrandABB
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMAO2020-Limas21
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSabio
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 2030
PriceUpon Request
Measurement PrincipleUV Absorption at 254 nm (Beer–Lambert Law)
Range Options0–100 / 0–200 / 0–500 ppb or 0–1 / 0–2 ppm
Detection Limit1 ppb
Zero Noise0.6 ppb RMS
Zero Drift<1.0 ppb/24 hr, <2.0 ppb/7 days
Span Drift<1% per month
Response Time20 s (10 s delay)
Accuracy±1 ppb
Linearity±1% of full scale
Sample Flow Rate1 L/min
Operating Temperature5–45 °C
Power Supply98–132 VAC / 196–264 VAC, 50/60 Hz
Analog OutputsFour independent, scalable (0.1 V / 1 V / 2 V / 5 V / 10 V)
Digital InterfacesUSB, RS-232/RS-485 (DB-9)
DisplayColor LCD with touchscreen, front-panel keys, external keyboard/mouse support
Data StorageInternal logging with timestamped records
Built-in Ozone Generator0.05–1.5 ppm @ 5 SLM, ±2% of setpoint or ±3 ppb @ 5 SLM
Auto Zero CompensationYes
Temperature & Pressure CompensationYes
Dimensions15.6 cm H × 36.4 cm W × 31.6 cm D
Weight9.1 kg