Empowering Scientific Discovery

Beijing Minnick Analytical Instrument & Equipment Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelM8880
Instrument TypeLaboratory Gas Chromatograph
ApplicationHigh-Purity Gas Analysis
Carrier Gas OptionsSingle selectable gas (e.g., He, H₂, or Ar)
Dual-Detector ConfigurationPDHID + TCD
Independent Temperature Zones8
Oven Programmed Ramps20-step
Back-Flush & Heart-Cut CapabilityIntegrated
Detection Limits (v/v)PDHID — H₂: 0.06 µL/L, CH₄: 0.08 µL/L, CO: 0.08 µL/L, C₂H₆: 0.01 µL/L, CO₂: 0.09 µL/L, C₂H₄: 0.01 µL/L, C₂H₂: 0.01 µL/L, C₃H₈: 0.01 µL/L, H₂S: 0.01 µL/L, C₃H₆: 0.01 µL/L, SO₂: 0.23 µL/L
TCD — O₂49 µL/L, N₂: 70 µL/L
PDHID SpecificationsPulsed Discharge Helium Ionization Detector
TCD SpecificationsBaseline Noise ≤ 20 µV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8810
Instrument TypeOnline Gas Chromatograph
Application FocusHigh-Purity Gas Analysis
Detector ConfigurationUp to 3 Simultaneous Detectors (PDHID, TCD, FID, FPD)
Communication InterfaceEthernet-enabled Industrial Bus Architecture
Compliance ContextDesigned for GLP/GMP-aligned environments with audit-ready data handling capabilities
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
Manufacturer TypeAuthorized Distributor & System Integrator
Regional ClassificationDomestic (China-Made)
ModelGC7890B
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelM8880
Instrument TypeLaboratory Gas Chromatograph
Application DomainHigh-Purity Gas Analysis
Carrier Gas OptionsSingle selectable gas (e.g., He, H₂, or Ar)
Detector ConfigurationDual-detector, multi-column parallel architecture
Temperature Control8 independent zones, 20-step programmable ramping
Advanced FunctionalityBuilt-in back-flush module enabling heart-cutting and column switching
Data SystemDedicated GC workstation with automated flammability triangle (CH₄–O₂–N₂) explosion hazard assessment
Detection Limits (v/v)PDHID — H₂ (0.06 µL/L), CH₄ (0.08 µL/L), CO (0.08 µL/L), C₂H₆ (0.01 µL/L), CO₂ (0.09 µL/L), C₂H₄ (0.01 µL/L), C₂H₂ (0.01 µL/L), C₃H₈ (0.01 µL/L), H₂S (0.01 µL/L), C₃H₆ (0.01 µL/L), SO₂ (0.23 µL/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8800 Series
Instrument TypeOnline Gas Chromatograph
Detector ConfigurabilityUp to three simultaneous detectors (TCD, uTCD, FID, FPD, ECD, NPD, PDHID)
Injection OptionsPacked column, split/splitless capillary, valve injection, 6-/12-position liquid auto-sampler, headspace autosampler, pyrolysis injector
Oven Temperature Range+4 °C above ambient to 450 °C (1 °C increment)
Oven Temperature Stability±0.1 °C at 200 °C
Oven Programmable Stages16 temperature ramps
Cooling Rate260 °C to 50 °C in ~6 min
Temperature Zones8 independently controlled zones
Carrier Gas ControlElectronic Pressure Control (EPC), pressure resolution 0.01 kPa, flow resolution 0.01 sccm
Display5.7-inch color TFT touchscreen
Data InterfaceEthernet (IEEE 802.3), PC-controlled operation or standalone mode
Remote CapabilityNetwork-enabled remote monitoring, unattended operation, distributed acquisition, centralized control
Multidimensional GC SupportCenter-cutting and valve-switching configurations enabled
SoftwareMethod-driven acquisition with full parameter storage and recall
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
ModelGC8800-II
OriginBeijing, China
Instrument TypeLaboratory Gas Chromatograph
Application FocusHigh-Purity Gas Analysis
Control InterfaceIEEE 802.3 Ethernet
EPC ModuleIntegrated Electronic Pressure Control (EPC) and Electronic Flow Control (EFC)
Autosampler CompatibilityDual-tower 24-position liquid autosampler
Optional Gas AutosamplingMNK Cylinder & Gas-Phase Autosampler
Ancillary Module SupportMNK Flash Vaporizer for LPG, Butadiene, and 1-Butene analysis
Data SystemMulti-instrument data aggregation
Regulatory AlignmentDesigned to support GLP-compliant workflows and 21 CFR Part 11–ready audit trail configuration (when paired with validated software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Model Variants110, 310, 410, 8610C, 8610D
ConfigurationBenchtop or Portable Chassis Options
DetectorsFID, TCD, SCD, PID (User-Selectable)
ComplianceASTM D1945, D1946, D3588, ISO 8573-5, USP <467>, EPA Method TO-14A/TO-15
Data SystemStandalone PC-Based Acquisition & Processing Software (No Dedicated Terminal Required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
Model23443
OriginUSA
TypePortable Thermal Conductivity-Based Leak Detector
Detectable GasesHe, N₂, Ar, CO₂, H₂
Power SourceRechargeable Ni-MH Battery (6 h typical runtime)
Operating Temperature0–48 °C
Relative Humidity0–97 % RH
CertificationsCE, RoHS, WEEE
ComplianceCompliant with EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS), and Japan’s JIS C 0950 (RoHS-equivalent)
Enclosure RatingIP54 (dust-protected, water-splashing resistant)
Probe InterfaceStandard 1/8" Swagelok-compatible stainless steel insertion probe
Auto-ShutdownEnabled after 5 min inactivity
Charging AdapterUniversal AC input (100–240 VAC, 50/60 Hz)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC-8810
Instrument TypeLaboratory Gas Chromatograph
Application DomainCoal Industry Specific
Detection LimitsPermanent Gases (N₂, CO₂, O₂) < 10 ppm
Analysis Time≤ 2 min (including backflush)
Modular ConfigurationUp to 4 independent GC channels
Detector TechnologyNEMS-based silicon micro-TCD
Flow ControlElectronic Pressure Control (EPC) per channel
Temperature ControlIndependent oven and column-zone heating per module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8800
Instrument TypeOnline Gas Chromatograph
Application DomainUltra-High-Purity (UHP) Gas Impurity Analysis
Detector TypePulsed Discharge Helium Ionization Detector (PDHID)
Carrier GasUltra-High-Purity Helium (≥99.999%, purified to ≤10 ppb total impurities)
Baseline Noise≤0.1 mV
Baseline Drift≤0.5 mV/30 min
Detection Limit≤1.0 × 10⁻¹⁰ g/mL
Gas Control OptionsManual Valving & Electronic Pressure Control (EPC)
Data TransmissionEthernet-enabled Remote Monitoring & Unattended Operation
Regulatory Compliance SupportASTM D7622, ISO 8573-8, SEMI F57, IEC 60400, USP <621>, FDA 21 CFR Part 11-ready audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelGC8800 (Dual-Detector)
Instrument TypeLaboratory Gas Chromatograph
Primary ApplicationHigh-Purity Gas Analysis
Detector ConfigurationPulsed Discharge Helium Ionization Detector (PDHID) + Secondary Detector (e.g., TCD or FID)
Carrier GasUltra-High-Purity Helium Only
Linear Range10⁵
Detection LimitSub-ppb for H₂, O₂, N₂, CO, CO₂, CH₄, C₂H₆, C₂H₄, C₂H₂, H₂S, C₃H₈, C₃H₆
Regulatory ComplianceDesigned to support GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
ModelPGC-8800
TypeOnline Gas Chromatograph
Primary ApplicationHigh-Purity Gas Analysis
Detection PrinciplePulsed Discharge Helium Ionization Detection (PDHID)
Detection Limits (PDHID)H₂ (5 ppb), He (5 ppb), O₂ (10 ppb), N₂ (10 ppb), Ar (10 ppb), Ne (500 ppb), CO (25 ppb), CO₂ (5 ppb), CH₄ (5 ppb), CF₄ (10 ppb), C₂F₆ (20 ppb), SO₂F₂ (20 ppb), C₃F₈ (20 ppb)
Complementary DetectorsTCD, FID
Sample PhaseGaseous
Operating ModeContinuous Unattended Online Monitoring
OriginBeijing, China
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMNK
OriginBeijing, China
ModelPGC-8800
Instrument TypeOnline Gas Chromatograph
Application FieldHigh-Purity Gas Analysis
DetectorsPDHID, TCD, FID
Detection Limits (ppb)H₂ (5), He (5), O₂ (10), N₂ (10), Ar (10), Ne (10), CO (25), CO₂ (5), CH₄ (5), CF₄ (10), C₂F₆ (20), SO₂ (20), F₂ (20), C₃F₈ (20)
Temperature Control Accuracy±0.01°C
Baseline Noise≤0.1 mV
Analog Outputs5–12 channels of 4–20 mA
Communication Interfaces1× Ethernet, 1× RS-232 (expandable)
Display10.1″ high-resolution capacitive touchscreen
EnclosureStandard 5U rack-mount chassis (482 × 432 × 222 mm)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0