- All
- Favorite
- Popular
- Most rated
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MY702-4/6 |
| Maximum Flash Vaporization Temperature | 230 °C |
| Heating & Jacket Temperature Range | Ambient +5 °C to 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Ports | 4 or 6 positions + 1 purge gas channel |
| Inlet Fitting | M14×1.5 internal thread quick-connect |
| Tubing | 1/16″ SilcoTek-passivated stainless steel |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 100 W |
| Dimensions (4-port) | 400 × 255 × 300 mm |
| Net Weight | 20 kg |
| Compliance | Designed for ASTM D6667, ASTM D7164, ISO 8570, and USP <621> gas chromatographic workflows requiring trace sulfur and oxygenate analysis |
| Brand | MNK |
|---|---|
| Model | MQY301 |
| Origin | Beijing, China |
| Configuration | 5-channel gas bag sampler + 1-channel liquid flash-vaporization inlet |
| Dimensions (W×D×H) | 400 × 255 × 300 mm |
| Net Weight | 15 kg |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 300 W |
| Maximum Flash-Vaporization & Jacket Temperature | 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Liquid Injection Pressure Range | 100–400 psi |
| Sample Transfer Line | Passivated stainless steel |
| Interface Options | AUX trigger, touch control, GC instrument control port |
| Inlet Valve | Integrated 6-position gas sampling valve with quantitative loop |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MG220 |
| Pricing | Upon Request |
| Operating Pressure Range | 0.7–4 MPa |
| Drive Gas | Dry Air or Inert Gas (0.4 MPa) |
| Auxiliary Gas Flow Rate | 50–200 mL/min |
| Internal Tubing | 1/16″ SilcoTek-Passivated Stainless Steel |
| Valve Core Volume Options | 0.06–2 μL (Standard: 1 μL) |
| Dead Volume | Minimized (<10 μL typical) |
| Repeatability | RSD < 2% (n ≥ 6) |
| Dimensions (W×D×H) | 130 mm × 200 mm × 200 mm |
| Mounting | Direct installation above GC inlet port |
| Weight | ~1.5 kg |
| Surface Treatment | SilcoTek® SilcoNert® 2000 inert coating applied to entire fluid path |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Standard Compliance | ASTM D3948, SH/T 0616–1995 |
| Test Principle | Gravimetric optical transmittance measurement of water separation kinetics in jet fuel |
| Accessories Included | Precision glass syringes, calibrated transfer pipettes, test cuvettes, reference standards |
| Configuration | Portable benchtop unit with integrated timer and optical sensor module |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GRACE 923 |
| Pricing | Available Upon Request |
| Certified Standard | Compliant with GB/T 11132 and ASTM D1319 |
| Average Pore Diameter | 32 Å |
| Pore Size Distribution | Narrow |
| Packaging | 500 g per bottle |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MNKSAG0609 |
| Pricing | Upon Request |
| Diameter | 47 mm |
| Pore Size | 0.8 µm |
| Pack Size | 100 per Box |
| Compliance | SH/T 0175–2004, ASTM D2274 |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MS200 |
| Sample Inlet Pressure Range (Liquid) | 0.69–2.75 MPa |
| Sample Inlet Pressure Range (Gas) | ≤2.07 MPa |
| Vaporization Temperature Control Range | Ambient to 150 °C |
| Transfer Line Heating Range | Ambient to 150 °C |
| Operating Ambient Temperature | –18 °C to +65 °C |
| Power Supply | 220 VAC, 50 Hz, max. 3.0 A |
| Dimensions (H×W×D) | 230 mm × 190 mm × 350 mm |
| Compliance | Designed for integration with GC and GC-MS systems in petroleum refining and hydrocarbon analysis labs |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | Model 1152 |
| Measurement Range | 0–1999 pS/m |
| Resolution | 1 pS/m |
| Accuracy | ±2% of reading + 1 pS/m |
| Display | 3-digit LCD, digit height 0.27 cm |
| Power Supply | 3 × alkaline batteries (6 V total) |
| Operating Temperature | 0–75 °C |
| Probe | Removable stainless-steel, intrinsically safe |
| Safety Certifications | UL, CSA (Canada), LCIE |
| Calibration | Internal reference, field-adjustable via two-button interface ("M" for Measure, "C" for Calibrate) |
| Overrange Indication | Leading "1" on display |
| Enclosure | Solvent-resistant molded polymer housing |
| Grounding | Banana jack terminal |
| Battery Low/Overrange Alerts | Visual indicators |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 1140 |
| Unit Price | USD 1.00 |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | JFTOT MARKIII |
| Compliance | ASTM D3241, GB/T 9169 |
| Consumables | Heating Rod & MNKJG0605 Filter Assembly |
| Supply Channel | Authorized Distributor |
| Brand | UOP |
|---|---|
| Origin | USA |
| Packaging | Amber Glass Bottle |
| Storage Requirement | Ambient, Under Nitrogen Atmosphere |
| Compliance | ASTM D1319-22, GB/T 11132-2022 |
| Application | Fluorescent Indicator Adsorption Chromatography of Liquid Petroleum Hydrocarbons |
| Brand | Komyo Rika |
|---|---|
| Origin | Japan |
| Model | AP-20 |
| Tube Format | Single-use colorimetric gas detection tube |
| Storage Requirement | Refrigerated (0–10 °C / 32–50 °F) |
| Packaging | AP-20 supplied in 20-tube boxes |
| Compliance | Designed per JIS K 0321 and ISO 8573-3 for compressed gas purity verification |
| Brand | EMCEE |
|---|---|
| Origin | USA |
| Model | 1140 |
| Compliance | ASTM D3948, SH/T 0616-1995 |
| Application | Aviation Turbine Fuel (Jet A/Jet A-1) Water Separation Performance Testing |
Show next