ATAGO
Filter
Showing 91–120 of 591 results
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DPH-2 |
| pH Range | 0.0–14.0 |
| Accuracy | ±0.1 pH (at 2.0–12.0, 25°C) |
| Resolution | 0.1 pH |
| Temperature Range | 0–50°C with Automatic Temperature Compensation (ATC) |
| Power | Four LR44 1.5V button cells |
| IP Rating | IP67 |
| Dimensions | 4.5 × 3.0 × 16.3 cm |
| Weight | 90 g (instrument only) |
| Calibration Points | pH 4.0, 7.0, and 10.0 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1 |
| Measurement Range | 1.3000–1.7100 (nD) / 0.0–95.0% Brix |
| Resolution | 0.0001 (nD) / 0.1% Brix |
| Accuracy | ±0.0002 (nD) / ±0.1% Brix |
| Automatic Temperature Compensation | 5–50°C |
| Temperature Measurement Range | 5–50°C (0.1°C resolution) |
| Power Supply | 100–240 VAC, 50/60 Hz, 10 VA |
| Dimensions & Weight | 13 × 29 × 31 cm, 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-Plus |
| Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7100 |
| Brix Range | 0.0–100.0% |
| Refractive Index Accuracy | ±0.0002 |
| Brix Accuracy | ±0.1% |
| Temperature Accuracy | ±0.2°C |
| Resolution | RI 0.0001, Brix 0.1% |
| Measurement Temp Range | 5–50°C |
| Interface | RS-232C |
| Power | AC Adapter (100–240 V, 50/60 Hz), 16 VA |
| Dimensions (Main Unit) | 13 × 29 × 31 cm |
| Weight (Main Unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-Plus |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0.0–100.0% Brix (or refractive index equivalent) |
| Accuracy | ±0.1% Brix |
| Compliance | ISO 21745, ASTM D1218, JIS K0061 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-Plus |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes (ATC) |
| Digital Display | Yes |
| Measurement Range | Refractive Index (nD): 1.3000–1.7100 |
| Brix | 0.0–100.0% |
| Accuracy | Refractive Index: ±0.0002 |
| Brix | ±0.1% |
| Resolution | Refractive Index: 0.0001 |
| Brix | 0.1% |
| Operating Temperature Range | 5–50°C (with Automatic Temperature Compensation) |
| Interface | RS-232C for printer and PC connectivity |
| Power Supply | AC adapter (100–240 V, 50/60 Hz) |
| Power Consumption | 16 VA |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-PLUS |
| Type | Benchtop Abbe Refractometer |
| Display | Digital LCD |
| Temperature Control | None |
| Refractive Index Range (nD) | 1.3000–1.7100 |
| Brix Range | 0.0–100.0% (with Automatic Temperature Compensation) |
| Resolution | nD: 0.0001, Brix: 0.1% |
| Accuracy | nD: ±0.0002, Brix: ±0.1% |
| Temperature Measurement Range | 5–50 °C |
| Temperature Accuracy | ±0.2 °C |
| Interface | RS-232C for printer or PC connection |
| Power Supply | AC adapter (100–240 V, 50/60 Hz) |
| Power Consumption | 16 VA |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Optional Accessories | Circulating water bath (Model 60-C5), Digital printer DP-63(C) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-PLUS |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7100 |
| Brix Range | 0.0–95.0% |
| Refractive Index Accuracy | ±0.0002 |
| Brix Accuracy | ±0.1% |
| Temperature Range | 5–50 °C (with automatic temperature compensation) |
| Resolution | 0.0001 (nD), 0.1% (Brix) |
| Power | 16 VA |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-Plus |
| Product Type | Benchtop Refractometer |
| Display | Digital |
| Temperature Control | None |
| Refractive Index Range | 1.3000–1.7100 |
| Brix Range | 0.0–100.0% |
| Refractive Index Accuracy | ±0.0002 |
| Brix Accuracy | ±0.1% |
| Temperature Compensation | Automatic (5–50 °C) |
| Resolution | nD: 0.0001, Brix: 0.1% |
| Power | 16 VA (AC Adapter: 100–240 V, 50/60 Hz) |
| Dimensions (Main Unit) | 13 × 29 × 31 cm |
| Weight (Main Unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-Plus |
| Type | Benchtop Refractometer |
| Display | Digital LCD |
| Temperature Control | None |
| Refractive Index Range | 1.3000–1.7100 (nD) |
| Brix Range | 0.0–100.00% |
| Resolution | ±0.0002 (nD), ±0.1% (Brix) |
| Dual-Scale Display | nD and %Brix |
| Sample Volume | < 0.1 mL |
| Interface | RS-232 for Printer/PC Connectivity |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-A1-PLUS |
| Type | Benchtop Digital Abbe Refractometer |
| Refractive Index Range | 1.3000–1.7100 nD |
| Brix Range | 0.0–100.0% |
| Refractive Index Resolution | 0.0001 |
| Brix Resolution | 0.1% |
| Accuracy | ±0.0002 nD / ±0.1% Brix |
| Temperature Compensation | Automatic (5–50 °C) |
| Temperature Accuracy | ±0.2 °C |
| Display | Digital LCD (nD, Brix%, Temp. °C) |
| Interface | RS-232C (printer & PC connectivity) |
| Power | AC adapter (100–240 V, 50/60 Hz), 16 VA |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.2743–1.6840 |
| Measurement Accuracy | ±0.0002 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 |
| Type | Benchtop Refractometer |
| Display | Digital LCD |
| Wavelength Range | 450–1550 nm (interference filter-based) |
| Refractive Index Range | 1.3278–1.7379 (at 450 nm) |
| Resolution | 0.0001 (nD), 0.1 (Abbe number) |
| Accuracy | ±0.0002 (nD, verified at 589 nm with standard test plate) |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 (1100 nm) |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | nD = 1.3278–1.7379 @ 450 nm |
| Accuracy | ±0.0002 nD |
| Wavelength Range | 450–1100 nm (interference filters) |
| Resolution | 0.0001 nD / 0.1 Abbe number |
| Operating Temperature | 5–50 °C |
| Light Source | Halogen lamp |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 (1100 nm) |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.3278–1.7379 (at 450 nm) |
| Measurement Accuracy | ±0.0002 for refractive index (nD) using test plates calibrated between 500–650 nm |
| Wavelength Range | 450–1100 nm (with interference filters) |
| Resolution | 0.0001 (nD), 0.1 (Abbe number νd/νe) |
| Operating Temperature | 5–50 °C |
| Light Source | Halogen lamp |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Optional Accessories | Circulating water bath 60-C5 (P/N 1923), Digital Printer DP-AD(B) (P/N 3145) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 (1550 nm) |
| Type | Benchtop Abbe Refractometer |
| Digital Display | Yes |
| Temperature Control | None |
| Refractive Index Range | 1.2662–1.6759 (at 1550 nm) |
| Refractive Index Accuracy | ±0.0002 (measured with 589 nm calibration plate) |
| Wavelength Range | 450–1550 nm (via interchangeable interference filters) |
| Resolution | 0.0001 (nD), 0.1 (Abbe number) |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3278–1.6840 |
| Accuracy | ±0.0002 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2 |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3278–1.7379 (450 nm) |
| Measurement Accuracy | ±0.0002 RI (with 500–650 nm filter) |
| Minimum Display Resolution | 0.0001 RI / 0.1 Abbe Number |
| Wavelength Range | 450–1100 nm (filter-based) |
| Temperature Measurement Range | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz, 160 VA |
| Dimensions & Weight | 13 × 29 × 31 cm, 6.0 kg (main unit) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2/1550 |
| Product Type | Benchtop Refractometer |
| Display | Digital LCD |
| Temperature Control | None |
| Refractive Index Range | 1.2662–1.7379 (wavelength-dependent) |
| Wavelength Range | 450–1550 nm |
| Resolution | 0.0001 (nD), 0.1 (Abbe number) |
| Accuracy | ±0.0002 (at 589 nm, verified with certified standard plate) |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M2/M4 Multi-Wavelength Abbe Refractometer |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3278–1.7379 (DR-M2 at 450 nm) |
| Refractive Index Resolution | 0.0001 |
| Refractive Index Accuracy | ±0.0002 (with 500–650 nm test plates) |
| Wavelength Range | 450–1100 nm (interference filter-equipped) |
| Measurement Temperature Range | 5–50 °C |
| Light Source | Halogen lamp |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4 (1550) |
| Type | Benchtop Abbe Refractometer |
| Display | Digital |
| Temperature Control | None |
| Refractive Index Range | 1.5219–1.9220 |
| Measurement Accuracy | ±0.0002 |
| Wavelength Capability | 1550 nm (NIR), compatible with optional NIR viewing eyepiece (681–1100 nm conversion) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4 |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.2743–1.6840 (at 1,100 nm) |
| Accuracy | ±0.0002 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4 (Up to 1100 nm) |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.3278–1.6840 |
| Accuracy | ±0.0002 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4 |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.5219–1.9218 (450 nm) |
| Measurement Accuracy | ±0.0002 (with 500–650 nm filter) |
| Resolution | 0.0001 (nD), 0.1 (Abbe number) |
| Wavelength Range | 450–1100 nm (NIR observation eyepiece required for 681–1100 nm) |
| Temperature Range | 5–50 °C |
| Data Output | Optional DP-AD digital printer |
| Power Supply | AC 160–240 V, 50/60 Hz |
| Dimensions & Weight | 13 × 29 × 31 cm, 6.0 kg (main unit) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4 (1100 nm) |
| Product Type | Benchtop Refractometer |
| Digital Display | Yes |
| Temperature Control | None |
| Measurement Range (nD at 1100 nm) | 1.4260–1.8258 |
| Resolution | 0.0001 (nD), 0.1 (Abbe number) |
| Accuracy | ±0.0002 (nD, with 500–650 nm interference filter) |
| Wavelength Range | 450–1100 nm (interference filters required) |
| Light Source | Halogen lamp |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4 |
| Measurement Range | nD = 1.4260–1.9220 (at 1550 nm) |
| Accuracy | ±0.0002 (at 589 nm) |
| Wavelength Range | 450–1550 nm (interference filter-based) |
| Temperature Control | Yes |
| Digital Display | Yes |
| Resolution | 0.0001 (nD), 0.1 (Abbe number) |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4/1550(A) |
| Type | Benchtop Refractometer |
| Digital Display | Yes |
| Temperature Control | None |
| Refractive Index Range | 1.5167–1.9166 (at 450 nm) |
| Accuracy | ±0.0002 RI (at 589 nm) |
| Wavelength Range | 450–1550 nm |
| Resolution | 0.0001 RI / 0.1 Abbe Number |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (Main Unit) | 13 × 29 × 31 cm |
| Weight (Main Unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DR-M4/1550 |
| Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | n = 1.5167–1.9166 (450 nm) |
| Accuracy | ±0.0002 (at 589 nm) |
| Wavelength Range | 450–1550 nm (with interchangeable interference filters) |
| Resolution | 0.0001 (refractive index), 0.1 (Abbe number) |
| Operating Temperature | 5–50 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (main unit) | 13 × 29 × 31 cm |
| Weight (main unit) | 6.0 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index Range | 1.5167–1.9166 |
| Measurement Accuracy | ±0.00002 (with 500–650 nm interference filters) |
| Wavelength Selection | 5 discrete wavelengths from 450 nm to 1550 nm |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | ES-421 |
| Measurement Principle | Conductivity Method |
| Salt Range | 0.00–10.0% (g/100g) |
| Resolution | 0.01% (0.00–2.99%), 0.1% (3.0–10.0%) |
| Accuracy | ±0.05% (0.00–0.99%), ±5% rel. (1.00–10.0%) |
| ATC Range | 10–40°C |
| Operating Temp. | 10–40°C |
| Power | 9V alkaline battery (006P) |
| Dimensions | 170 × 90 × 40 mm |
| Weight | 220 g (host only) |
| IP Rating | IP64 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | ES-421 |
| Measurement Principle | Conductivity-based Salt Concentration Detection |
| Display | Full-digit LCD |
| Water Resistance | IP65-rated housing |
| Sample Volume | < 0.1 mL |
| Operating Temperature Range | 10–40 °C |
| Calibration | Air-zero function |
| Compliance | CE-marked, conforms to JIS Z 8401 (Accuracy of Measurement) |