Beifen Sanpu
Filter
Showing 31–60 of 450 results
| Key | Brand: Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Loop Volume | 1 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Model | ADTS-12A |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Valve Injection Zone Temp Range | Ambient to 260 °C |
| Transfer Line Temp Range | Ambient to 450 °C |
| Cold Trap Temp Range | −35 °C to Ambient |
| Temperature Control Accuracy | < ±0.5 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Positions | 12 |
| Cold Trap Cooling Method | Semiconductor-based Electronic Cooling |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Injection Mechanism | Motor-driven 6-port Valving |
| Dimensions (L×W×H) | 300 × 385 × 550 mm |
| Weight | ~32 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100 to 450 °C |
| Cryo-Focusing Trap Temp Range | −35 to Ambient °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Dimensions | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ADTS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 1 tube per run |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AeTDS-20A |
| Price | USD 21,800 (FOB Beijing) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AH-S-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Loop Volume | 1 mL |
| Brand | Beifen Sanpu |
|---|---|
| Model | AH.S-20A PLUS |
| Instrument Type | Automated Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Capacity | 20-position vial carousel |
| Vial Compatibility | 10 mL or 20 mL crimp-top headspace vials |
| Oven Temperature Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Compliance | Designed for HJ 1067–2019 (China EPA Standard Method for BTEX and Styrene in Water) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AH1S-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | AH3S-20A Plus |
| Carrier Gas Pressure Range & Control | 14.5 psi |
| Maximum Injector Temperature | 260 °C |
| Detector Configuration | Dual FID |
| Compatible Sample Introduction | Automated Headspace Sampler (AHS-20A Plus) |
| Column Compatibility | HP-1 and HP-1wax capillary columns |
| Operating Standard | YC/T 207–2006] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | AH9S-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Vial Compatibility | 10 mL or 20 mL headspace vials |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Position Capacity | 20 positions |
| Vial Sizes Supported | 10 mL or 20 mL |
| Temperature Stability | < ±0.5 °C |
| RSD | < 1.0% (100 ppm ethanol in water) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge/Flush Flow | 0–100 mL/min (adjustable) |
| Communication Interface | USB |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Oven Temperature Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL and 20 mL] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Quantitative Loop Temperature Control | Ambient to 200 °C (1 °C increment) |
| Sample Transfer Line Temperature Control | Ambient to 200 °C (1 °C increment) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL or 3 mL) |
| Vial Capacity | 20 mL (optional: 10 mL) |
| Vial Positions | 12 |
| Temperature Stability | ±0.5 °C |
| RSD (n=6, 40 ppm ethanol in water) | ≤1.5% |
| Purge/Backflush Flow | 0–500 mL/min (continuously adjustable) |
| Dimensions (L×W×H) | 200 × 360 × 420 mm |
| Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | AHS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C |
| Valve & Quantitation Loop Temperature Control Range | Ambient to 220 °C |
| Quantitation Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Temperature Control Accuracy | < ±0.5 °C |
| RSD (n=6, 40 ppm ethanol in water) | ≤1.5% |
| Purge Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions (L×W×H) | 200 × 360 × 420 mm |
| Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Injection Valve Temperature Control Range | Ambient to 200 °C (1 °C increments) |
| Quantitative Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Integrated GC Trigger Output | Yes |
| Method Storage | 10 user-editable methods |
| Safety Features | Overtemperature cutoff with thermal shutdown |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Loop Heating Range | Ambient to 200 °C (1 °C increment) |
| Transfer Line Heating Range | Ambient to 200 °C (1 °C increment) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL or 3 mL) |
| Vial Capacity | 12 positions |
| Vial Size | 20 mL (optional: 10 mL) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (across vials) | < ±0.5 °C |
| RSD (n=6, 40 ppm ethanol in water) | ≤1.5% |
| Purge/Backflush Flow | 0–500 mL/min (continuously adjustable) |
| GC Synchronization | Yes |
| Dimensions (L×W×H) | 200 × 360 × 420 mm |
| Weight | ~18 kg] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 12 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AHS-10A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 12 positions |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Loop Heating Range | Ambient to 200 °C (1 °C increments) |
| Transfer Line Heating Range | Ambient to 200 °C (1 °C increments) |
| Quantitative Loop Volume | 1 mL (optional: 0.5 mL or 3 mL) |
| Vial Format | 20 mL standard (10 mL optional) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity Across Positions | < ±0.5 °C |
| RSD for Injection Precision | ≤1.5% (n=6, 40 ppm ethanol in water) |
| Purge/Backflush Flow Rate | 0–500 mL/min (continuously adjustable) |
| Dimensions (L×W×H) | 200 × 360 × 420 mm |
| Net Weight | ~18 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHS-201A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AHS-20A |
| Price Range | USD 7,000 – 14,000 |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Heating Range | Ambient +1°C to 200°C |
| Valve & Transfer Line Heating Range | Ambient +1°C to 200°C |
| Loop Volume | 1 mL |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL (customizable) |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (optional: 0.5, 2, or 5 mL) |
| RSD | < 1.0% (measured on 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB communication with PC |
| Compliance Standards | GA/T 842–2009, GB 5749–2006, GB 8537–2008, HJ 642–2013, HJ 643–2013, HJ 714–2014, HJ 736–2015, HJ 810–2016, HJ 895–2017, Chinese Pharmacopoeia (2015 Ed., Vol. III & IV), YC/T 207–2014, SN/T 3616–2013, SN/T 4068–2014 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Position Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL vials |
| RSD | <1.0% (at 100 ppm ethanol in water) |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Purge/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Communication Interface | USB |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AHS-20A PLUS |
| Instrument Type | Laboratory Water Quality Analyzer |
| Target Analytes | Volatile Organic Compounds (VOCs) |
| Detection Method | Headspace-Gas Chromatography with Flame Ionization Detection (HS-GC-FID) |
| Compliance Standards | GB 5749-2006, GB 3838-2002, GB 8537-2008 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AHS-20A PLUS |
| Instrument Type | Laboratory Headspace Sampler |
| Application Scope | General-Purpose |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 100 to 350 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injection Port Max Operating Temperature | 100–350 °C |
| Injection Port Pressure Setting Range | 0–970 kPa |
| Total Injection Port Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | AHS-20A Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Capacity | 20-position carousel |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |