| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBN702 |
| Price Range | USD 14,000 – 42,000 |
| Air Flow Range | 0–100 L/min |
| Flow Accuracy | ±2% FS |
| Differential Pressure Range | −1000 to +1000 Pa |
| Pressure Resolution | 1 Pa |
| Pump Capacity | ≥100 L/min |
| Test Flow Rate | (85 ± 1) L/min (constant) |
| Dimensions | 380 × 620 × 825 mm |
| Headform Sizes | 30 mm, 25 mm, 20 mm |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBN702-a |
| Price Range | USD 14,000 – 43,000 |
| Airflow Range | 0–100 L/min |
| Airflow Accuracy | ±2% FS |
| Differential Pressure Range | −1000 to +1000 Pa |
| Pressure Resolution | 1 Pa |
| Test Flow Rate | (85 ± 1) L/min (constant) |
| Pump Capacity | ≥100 L/min |
| Dimensions (W×D×H) | 380 × 620 × 825 mm |
| Headform Sizes | 30 mm, 25 mm, 20 mm |
| Power Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBR |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Hot Seal Pressure | 0.04–0.8 MPa |
| Hot Tack Time | 0–99 s |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (L×W×H) | 600 × 300 × 220 mm |
| Specimen Length | 200 mm |
| Force Measurement Range | 0–300 N |
| Compliance Standards | ASTM F1921, ASTM F2029, QB/T 2358, YBB00122003 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GBW-180 |
| Price Range | USD 70,000–112,000 (FOB Guangzhou) |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±1% FS |
| O₂ Detection Range | 0–25% |
| O₂ Detection Accuracy | ±1% FS |
| Pressure Detection Range | 0–100 kPa |
| Pressure Detection Accuracy | ±1% FS |
| Gas Flow Control Range | 0.01–10 L/min |
| Flow Control Accuracy | ±1.0% FS |
| Temperature Control Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Reactor Volume per Chamber | 3 L |
| Max. Number of Simultaneous Reactors | 18 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 5 kW |
| Dimensions (L×W×H) | 6950 × 1800 × 650 mm |
| Weight | 1500 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model No. | GBW(E)130541 |
| Certification | National Secondary Standard Substance (P.R. China) |
| Applicable Standards | GB/T 1038–2000 (Differential Pressure Method), ASTM D1434, ISO 2556 |
| Primary Use | Calibration, Verification & Metrological Traceability for Gas Permeability Testers |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | GC-9802 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 μm film thickness), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (optional packed column inlet) |
| Oven Dimensions | 240 × 210 × 240 mm (W × D × H) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Carrier Gases | High-purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), clean oil-free air (0.4 MPa, dry) |
| Gas Line Interface | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GC-9802-A |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific Analysis |
| Oven Temperature Range | Up to 400 °C |
| Ramp Rate | 0–40 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Detector | FID (Hydrogen Flame Ionization Detector), Optional TCD/ECD/NPD |
| FID Sensitivity | Mt ≤ 1 × 10⁻¹¹ g/s (n-Hexadecane) |
| Baseline Drift | ≤ 0.02 mV/h |
| Noise | ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (Optional Packed Column Injector) |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±0.1% of setpoint |
| Carrier Gas | High-Purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), Clean Air (0.4 MPa, oil-free, particle-free) |
| Gas Line Connection | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9802-P |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Medical Device Compliance Testing |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm) |
| Oven Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramp Stages | 16 |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Run Time | 6000 min |
| Injection Mode | Split/Splitless with Septum Purge |
| Optional Accessories | 20-Position Headspace Autosampler, Oil-Free Air Generator (3 L/min), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Cylinder (99.999%) with Regulator |
| Software | Dual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Scroll Functionality, PDF Report Export, and Manual Trigger Button Support |
| Brand | GBPI |
|---|---|
| Model | GC-9802A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 40–400 °C |
| Temperature Ramp Rate | 0–40 °C/min |
| Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-Hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Column Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Display | Integrated LCD with real-time temperature and status monitoring |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (H×W×D) | 500 × 550 × 500 mm |
| Compliance Standards | QB/T 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Model | GC-9802B |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose, with optimized configuration for residual solvent quantification |
| Oven Temperature Range | 40–400 °C |
| Temperature Ramp Rate | 0–40 °C/min |
| Cool-down Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 fused-silica capillary column (50 m × 0.32 mm ID × 0.5 µm film thickness), max. operating temperature 400 °C |
| Data System | Integrated chromatography data workstation with real-time acquisition, baseline correction, peak integration, calibration curve generation, PDF report export, and audit-trail-ready operation log |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Organic Solvent Analysis |
| Oven Temperature Range | 40–400 °C |
| Maximum Ramp Rate | 0–40 °C/min |
| Cooling Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 µm film thickness), Max Temp: 400 °C |
| Display | Integrated LCD with Real-Time Temperature Monitoring |
| Data System | PC-Based Workstation with Chromatographic Acquisition & Quantitative Analysis Software |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GC9802-K |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Medical Device Testing |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm) |
| Oven Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramping | 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Run Time | 6000 min |
| Injection Mode | Split/Splitless with Septum Purge |
| Optional Accessories | Zero-Air Generator (3 L/min, oil-free, dehydrated/deoiled), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Supply (99.999%, cylinder + regulator), EO Certified Reference Standards |
| Software | Dual-Channel Chinese GUI Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, Audit-Trail-Ready Data Logging |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-K1 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Volatile Organic Compounds |
| Detector | Flame Ionization Detector (FID), Optional Alternative Detectors Available |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm), Optional Alternate Columns Supported |
| Autosampler | 20-Position Headspace Sampler |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramps | Up to 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Accessories | Oil-Free Air Generator (3 L/min, with oil/water removal), Hydrogen Generator (300 mL/min, 99.999% purity), High-Purity Nitrogen Cylinder (99.999%, regulator included, locally sourced) |
| Calibration Standard | Certified Ethylene Oxide Reference Material |
| Data System | Dual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, and Manual Start Button Integration |
| Injection System | Split/Splitless Capillary Injector with Septum Purge Function |
| Safety Features | Dual-Layer Over-Temperature Protection (Software + Hardware), Advanced Acoustic Damping |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-K2 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector | Flame Ionization Detector (FID), optional alternative detectors |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional alternate columns |
| Headspace Sampler | 20-position |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramp Stages | 16 |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Air Generator | Oil-free, with oil/water removal, 3 L/min |
| Optional H₂ Generator | 300 mL/min, purity ≥99.999% |
| Carrier Gas | High-purity nitrogen (99.999%), supplied via cylinder with regulator (local procurement) |
| Certified EO Standard | Included |
| Data System | Dual-channel Chinese-language chromatography workstation with instrument control |
| Injection System | Split/splitless capillary inlet with septum purge function |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-UO |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Primary Application Field | Environmental & Medical Device Residue Testing |
| Detector | Flame Ionization Detector (FID), optional alternative detectors available |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional columns supported |
| Headspace Sampler | 20-position automated unit |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmed Temperature Ramping | Up to 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Accessories | Oil-free air generator (3 L/min, with oil/water removal) |
| Injection System | Split/splitless capillary inlet with septum purge |
| Data System | Dual-channel Chinese-language chromatography workstation with instrument control, real-time chromatogram display, zoom/pan functionality, automated report generation (PDF export), and manual hardware start trigger |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GF-1600B |
| Control System | Mitsubishi Micro-PLC |
| Max. Sealing Speed | 120 units/min (adjustable 30–120) |
| Bag Width Range | 60–120 mm |
| Bag Length Range | 70–230 mm |
| Tube Diameter | 8.5 mm / 10 mm (standard) |
| Sealing Temperature Range | 0–300 °C |
| Power Supply | 380 V, 50 Hz |
| Total Power Consumption | 6 kW |
| Compressed Air Requirement | 0.8 MPa, 45 L/min |
| Machine Dimensions | Φ2120 mm × 1000 mm (H) |
| Control Cabinet Dimensions | 600 × 600 × 1500 mm (L×W×H) |
| Net Weight | 1200 kg |
| Positioning Accuracy | ≤ ±0.02 mm |
| Sealing Stations | 4 hot-seal + 1 preheat + 1 cooling |
| Construction Materials | Anodized aluminum frame + food-grade stainless steel contact surfaces |
| Compliance | Designed to meet GMP requirements for food and pharmaceutical packaging environments |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GF-1800 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GH-D |
| Price | Upon Request |
| Measurement Range | 0–5 mm |
| Resolution | 0.1 µm |
| Sample Feed Interval | 0–1000 mm |
| Measurement Points per Scan | 1–10 |
| Display | LCD with Real-Time Statistical Output (Max/Min/Avg/Current) |
| Interface | RS-232 or USB for PC Connectivity |
| Operating Mode | Manual & Motorized Auto-Scan |
| Data Export | CSV, TXT, or via Optional GBPI ThicknessMaster™ Software |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GM-1 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GM-1G |
| Pricing | Available Upon Request |
| Test Standards | GB 10006, ISO 8295, TAPPI T816 |
| Friction Coefficient Range | 0.001–0.999 |
| Resolution | 0.001 |
| Force Measurement Range | 0–9.8 N |
| Slider Velocity | 100 ± 10 mm/min |
| Travel Distance | 100 ± 5 mm |
| Max Sample Thickness | ≤2 mm |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 g ± 2 g |
| Test Platform Size | 200 mm × 470 mm |
| Overall Dimensions | 470 mm × 350 mm × 220 mm |
| Power Consumption | 100 W |
| Power Supply | AC 220 V, 50 Hz |
| Weight | 12.5 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GM-1L |
| Pricing | Upon Request |
| Friction Coefficient Range | 0.001–0.999 |
| Resolution | 0.001 |
| Force Measurement Range | 0–9.8 N |
| Slider Velocity | 100 ± 10 mm/min |
| Travel Distance | 100 ± 5 mm |
| Max Sample Thickness | ≤2 mm |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 g ± 2 g |
| Test Platform Size | 200 mm × 470 mm |
| Overall Dimensions | 470 mm × 350 mm × 220 mm |
| Power Consumption | 100 W |
| Power Supply | AC 220 V, 50 Hz |
| Weight | 12.5 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GM-4D |
| Price Range | USD 7,000 – 14,000 |
| Friction Coefficient Range | 0.01–0.999 |
| Measurement Accuracy | ±2% |
| Force Sensor Range | 0–10 N |
| Slider Speed | 100 mm/min (infinitely variable) |
| Slider Dimensions | 63 × 63 mm |
| Slider Mass | 200 ± 2 g |
| Temperature Control Range | Ambient to 75 °C (optional) |
| Test Platform Size | 200 × 470 mm |
| Max Sample Thickness | ≤2 mm |
| Dimensions (W×D×H) | 470 × 330 × 210 mm |
| Weight | 37 kg |
| Power | 100 W |
| Supply | AC 220 V ±10%, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GM-4E |
| Price Range | USD 1,400 – 7,000 |
| Standard Compliance | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| COF Range | 0.01–0.999 |
| Measurement Accuracy | ±2% |
| Force Range | 0–10 N |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 ± 2 g |
| Test Speed | Adjustable, default 100 mm/min (stepless) |
| Temperature Control Option | Ambient to 75 °C |
| Specimen Thickness Limit | ≤2 mm |
| Base Plate Size | 200 mm × 470 mm |
| Overall Dimensions | 470 mm × 330 mm × 210 mm |
| Weight | 37 kg |
| Power | 100 W, AC 220 V ±10%, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GM-4Q |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 7,000 |
| Compliance Standards | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| CoF Measurement Range | 0.01–0.999 |
| Force Measurement Accuracy | ±2% |
| Load Cell Range | 0–10 N |
| Slider Mass | 200 ± 2 g |
| Slider Dimensions | 63 × 63 mm |
| Test Speed | Adjustable, default 100 mm/min (infinitely variable) |
| Temperature Control Range (optional) | Ambient to 75 °C |
| Specimen Thickness Limit | ≤2 mm |
| Test Platform Size | 200 × 470 mm |
| Overall Dimensions | 470 × 330 × 210 mm |
| Weight | 37 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 100 W |
| Brand | GBPI |
|---|---|
| Model | GM-4RR |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Compliance Standards | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| COF Measurement Range | 0.01–0.999 |
| Force Measurement Accuracy | ±2% |
| Load Cell Range | 0–10 N |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 ± 2 g |
| Test Speed | Adjustable from 100 mm/min (stepless variable speed) |
| Temperature Control Range (optional) | Ambient to 75 °C |
| Specimen Thickness Limit | ≤2 mm |
| Test Platform Size | 200 mm × 470 mm |
| Overall Dimensions | 470 mm × 330 mm × 210 mm |
| Weight | 37 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 100 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GM-4T |
| Price Range | USD 1,400 – 7,200 |
| Standard Compliance | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| CoF Range | 0.01–0.999 |
| Measurement Accuracy | ±2% |
| Load Cell Range | 0–10 N |
| Slider Dimensions | 63 mm × 63 mm |
| Slider Mass | 200 ± 2 g |
| Test Speed | Adjustable, default 100 mm/min (stepless) |
| Temperature Control | Ambient to 75 °C (optional) |
| Specimen Thickness Limit | ≤2 mm |
| Test Platform Size | 200 mm × 470 mm |
| Overall Dimensions | 470 mm × 330 mm × 210 mm |
| Weight | 37 kg |
| Power | 100 W, AC 220 V ±10%, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GM-5A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Standards Compliance | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| COF Range | 0.01–0.999 |
| Measurement Accuracy | ±2% |
| Load Cell Range | 0–10 N |
| Slider Mass | 200 ± 2 g |
| Slider Dimensions | 63 × 63 mm |
| Test Speed | Adjustable from 100 mm/min (stepless) |
| Temperature Control Option | Ambient to 75 °C |
| Specimen Thickness Limit | ≤2 mm |
| Test Platform Size | 200 × 470 mm |
| Overall Dimensions | 470 × 330 × 210 mm |
| Weight | 37 kg |
| Power | AC 220 V ±10%, 50 Hz, 100 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | GM-5D |
| Compliance | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| CoF Range | 0.01–0.999 |
| Measurement Accuracy | ±2% |
| Force Range | 0–10 N |
| Slider Mass | 200 ± 2 g |
| Slider Dimensions | 63 × 63 mm |
| Standard Test Speed | 100 mm/min (infinitely variable) |
| Temperature Control Option | RT–75 °C |
| Specimen Thickness Limit | ≤2 mm |
| Test Platform | 200 × 470 mm |
| Overall Dimensions | 470 × 330 × 210 mm |
| Weight | 37 kg |
| Power | 100 W, AC 220 ± 10 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | GM-6 |
| Measurement Range | 0.01–0.999 (COF) |
| Accuracy | ±2% |
| Force Sensor Range | 0–10 N |
| Slider Mass | 200 ± 2 g |
| Slider Dimensions | 63 × 63 mm |
| Standard Test Speed | 100 mm/min (infinitely variable) |
| Temperature Control | Ambient to 75 °C (optional) |
| Specimen Thickness Limit | ≤ 2 mm |
| Test Platform Size | 200 × 470 mm |
| Dimensions | 470 × 330 × 210 mm |
| Weight | 37 kg |
| Power | AC 220 ± 10 V, 50 Hz, 1000 W |
| Brand | GBPI |
|---|---|
| Model | GM-6A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 7,000 |
| Standards Compliance | GB/T 10006–1988, ASTM D1894–2014, ISO 8295–2004, TAPPI T816 |
| COF Range | 0.01–0.999 |
| Measurement Accuracy | ±2% |
| Force Range | 0–10 N |
| Slider Mass | 200 ± 2 g |
| Slider Dimensions | 63 × 63 mm |
| Test Speed | Adjustable from 100 mm/min (stepless) |
| Temperature Control Option | Ambient to 75 °C |
| Specimen Thickness Limit | ≤2 mm |
| Test Platform Size | 200 × 470 mm |
| Overall Dimensions | 470 × 330 × 210 mm |
| Weight | 37 kg |
| Power Input | AC 220 V ±10%, 50 Hz, 1000 W |