Generic
Filter
Showing 4141–4170 of 5735 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-1700 |
| Price Range | USD 14,000 – 28,500 |
| Instrument Class | High-Temperature Vacuum Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (automated circle fitting) |
| Sample Stage Dimensions | 100 × 100 mm |
| Image Magnification | 55–320 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Maximum Operating Temperature | 1600 °C (in inert atmosphere) |
| Vacuum Limit | ≤5×10⁻⁵ Pa (with turbo-molecular + backing pump configuration) |
| Heating Control | 40-segment programmable PID via B-type thermocouples (Pt/Rh) |
| Temperature Resolution | ±0.1 °C (<1000 °C), ±1 °C (≥1000 °C) |
| Cooling System | Closed-loop water chiller (5–35 °C, 10–20 L/min flow, 1.0–1.3 bar pressure, 1200 W cooling capacity) |
| Optical System | 300-mm working distance telecentric lens, 0.7–4.5× continuous zoom, industrial-grade low-light color CCD (1.3 MP) |
| Software Capabilities | Multi-method contact angle calculation (θ/2, tangent, circle/ellipse/curve fitting), time- and temperature-triggered image capture (min. interval: 0.1 s), left/right asymmetry analysis, automated averaging, GLP-compliant data logging with timestamped image–value pairing and Excel export |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI-2000A |
| Price Range | USD 2,800–7,200 |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±1° (θ/2 method), ±0.1° (circle fitting) |
| Sample Stage Dimensions | 120 × 80 mm |
| Optical Magnification | 0.7×–5× continuous zoom |
| Surface/Interfacial Tension Range | 0.001–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCI-KLL-S |
| Instrument Type | Portable Water Sampler |
| Sample Tube Diameter Compatibility | 2" and 4" monitoring wells |
| Construction Materials | Anodized aluminum, stainless steel, POM, NBR seals (11-70 Shore A) |
| Sample Vessel Options | PVC transparent tube or anodized aluminum tube |
| Nominal Sample Volumes | 500 mL / 1000 mL |
| Outer Diameter | 49 mm / 90 mm |
| Total Length | 1750 mm / 1100 mm |
| Release Trigger Mechanism | Electrical contact probe with depth indication |
| Maximum Suspended Load Capacity | 1000 g / 1800 g |
| Drain Nozzle Diameter | 5 mm / 7.5 mm |
| Upper Sampling Edge Distance from Probe Tip | ~850 mm / ~600 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI300C2 |
| Price Range | USD 14,000 – 28,500 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate (ISO 6295, ASTM D971) |
| Trough Material | PTFE (fully fluorinated) |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upstroke & Downstroke |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temp. | Ambient (compatible with external thermostatic bath) |
| RH Range | 30–85% |
| Optional Configurations | Dual-trough, multi-trough, or custom-area troughs |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vortex-Genie 2 |
| Price | USD 2,950 (FOB US) |
| Speed Range | 600–3200 rpm |
| Operation Modes | Continuous or Touch-Activated |
| Motion Type | Circular Orbital |
| Housing Material | Die-Cast Aluminum Alloy |
| Amplitude | 4.5 mm |
| Speed Indication | Analog Dial Scale |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | IVM-1000 |
| Price Range | USD 140–1,400 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MX-S (SCILOGEX, USA) |
| Price Range | USD 140–700 |
| Instrument Type | Ambient-Temperature Orbital Shaker |
| Timer Function | Continuous Operation Only |
| Oscillation Frequency | 0–2500 rpm |
| Oscillation Amplitude | 4 mm (orbital diameter 4 mm) |
| Temperature Range | Ambient +5°C to 40°C |
| Platform Quantity | 1 single platform |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECG Catheter |
| Pricing | Available Upon Request |
| Catheter Material | Polyimide Tubing |
| Effective Length | 15 cm (6") |
| Sizes | 1.1F (0.37 mm) and 2F (0.64 mm) |
| Electrode Material | Platinum |
| Electrode Length | 0.25 mm |
| Inter-Electrode Spacing | 0.5 mm and 1.0 mm (custom spacing available) |
| Electrode Configuration | Side-mounted at tip |
| Connector Type | Redel 14-pin |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT111B (Mouse), FT211B (Rat) |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Scisense FV892 |
| Pricing | Upon Request |
| Pressure Output | 1 V/100 mmHg (custom output ranges available) |
| Power Supply | External AC adapter, ±12 VDC |
| Dimensions (H × W × L) | 16.8 cm × 22.6 cm × 6.9 cm |
| Calibration Control | 10-position output gain switch |
| Catheter Cable Length Options | 91 cm or 152 cm |
| Output Interface | Standard BNC analog output |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Scisense PV Catheter Series (3F, 5F, 7F) |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Scisense! |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VSL |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 410 (Single-Phase) / Model 420 (Dual-Phase) |
| Dynamic Reserve | 60 dB |
| Frequency Range | 10 Hz – 100 kHz |
| Input Sensitivity | 3 µV – 1 V (full-scale output) |
| Input Impedance | 10¹² Ω ║ 1 nF (DC-coupled) |
| Output Time Constant | 100 µs – 30 s |
| Gain Accuracy | ±1% |
| Gain Stability | 200 ppm/°C |
| Max Output Voltage | ±16 V (pre-clamp) |
| Phase Adjustment | 90° coarse steps + 0–100° fine adjustment |
| Reference Input | TTL or sine wave, 100 mV rms min (sine), 5 V min (pulse) |
| Power | 115/230 V AC, 50–60 Hz, ≤10 VA |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SCJ-70 |
| Pricing | Available Upon Request |
| Temperature Range | −70 °C to 0 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Display Resolution | 0.1 °C |
| Hammer Blade Radius | 1.6 ± 0.1 mm |
| Impact Velocity | 200 ± 20 cm/s |
| Specimen Dimensions | 20 × 2.5 × 2.5 mm |
| Lower Jaw Arc Radius | 4.0 ± 0.1 mm |
| Clearance Between Blade Outer Edge and Clamp | 2.0 ± 0.1 mm |
| Distance from Impact Point to Clamp Centerline | 3.6 ± 0.1 mm |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TCOPRS-CCR-SW-25 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CF-10N, CF-20NW |
| Pricing | Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-726 |
| Price Range | USD 14,000 – 43,000 |
| Instrument Type | Specialty Flex-Abrasion Fatigue Tester |
| Maximum Test Load | 2000 g |
| Oscillation Frequency | 120 cycles per minute (cpm) |
| Net Weight | 60 kg |
| Specimen Mounting | Single specimen |
| Clamp Width | 45 mm |
| Max Clamp Spacing | 35 mm |
| Stroke Length | Adjustable up to 50 mm |
| Applied Load Range | 0.2–2.0 kg (via calibrated weights) |
| Load Application | Dead-weight loading with incremental mass sets |
| Display | 6-digit LCD digital counter |
| Power Supply | AC 220 V, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Scott Volumeter |
| Pricing | Available Upon Request |
| Standards Compliance | ASTM B329-90, USP <616>, NF 18 |
| Funnel Mesh Options | 10, 16, 18, or 40 mesh |
| Density Cup | Certified 25 cm³ brass cup (standard) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SCQ-HD300A |
| Instrument Category | Constant-Temperature Bath |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Refrigeration & Heating Dual-Mode |
| Bath Volume | 5 L |
| Temperature Range | RT to +100 °C |
| Temperature Stability | ±0.1 °C |
| Ultrasonic Power | 180 W |
| Heating Power | 1000 W |
| Inner Chamber Dimensions | 300 × 150 × 100 mm |
| Timer Range | 1–600 min |
| Drain Valve | Yes |
| Sound-Dampening Lid & Stainless Steel Basket | Yes |
| Power Supply | 220 V / 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Models | SCS112 / SCSe124 / SCSe126 |
| Cleaning Method | Wet Chemical & DI Water-Based Cleaning |
| Equipment Type | Single-Wafer Manual Processing Station |
| Maximum Substrate Diameter | 8 in (SCS112) or 10 in (SCSe124/SCSe126) |
| System Dimensions (W×D×H) | 26 in × 21 in × 40 in |
| Spindle Speed | Up to 2500 rpm |
| Control Architecture | Microprocessor-Based with Touchscreen GUI (SCSe124/SCSe126) or Keypad Interface (SCS112) |
| Preset Recipes | 3 (SCS112) or 10 (SCSe124/SCSe126) |
| Mechanical Arms | 1 (SCS112), 2 (SCSe124), or 4 (SCSe126) |
| Chamber Material | Chemically Resistant Polypropylene |
| Exhaust Configuration | Radial Laminar Flow Chamber (SCSe124/SCSe126) |
| Drying Options | High-velocity N₂ purge, IR heating lamp, or heated DI water rinse |
| Safety Features | Interlocked lid, positive-pressure chamber cover, emergency stop circuitry |
| Power Supply | 220 VAC, 10 A, 50/60 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SD-160 |
| Price Range | USD 1,400 – 7,200 (est.) |
| Target Materials (Standard) | Au |
| Optional | Ag, Pt |
| Target Dimensions | 50 mm × 0.1 mm |
| Control Mode | Manual |
| Chamber Dimensions | Ø150 mm × H120 mm |
| Sample Stage Diameter | 70 mm |
| Sputtering Gases | Ar, N₂, O₂ |
| Max Sputtering Current | 30 mA (rated), 50 mA (peak) |
| Sputtering Rate | >4 nm/min (Au on Si under standard Ar conditions) |
| Input Power | 220 V AC, 50 Hz (110 V option available) |
| Vacuum Pump | High-performance two-stage rotary vane pump (integrated) |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SD202-TB / SD202-1B / SD202-2B |
| Temperature Range | RT+20 °C to 200 °C |
| Temperature Uniformity | ±3.5% (upright models), ±0.5 °C (benchtop TB) |
| Temperature Fluctuation | ±0.5 °C |
| Chamber Volume | 27 L (TB), 91 L (1B), 150 L (2B) |
| Power Rating | 1.0 kW (TB), 1.2 kW (1B), 1.5 kW (2B) |
| Construction | Stainless Steel Interior |
| Control System | PID Digital Temperature Controller |
| Safety Features | Independent Over-Temperature Cut-Off, Short-Circuit Protection |
| Compliance | JB/T 5520–1991 |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D2440 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SDT-XP-3160 |
| Pricing | Upon Request |
| Detection Principle | Catalytic Bead (Pellistor) Combustion |
| Detection Range | 0–5000 ppm or 0–1 vol% |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Setpoints | 250 ppm / 500 ppm |
| Display | Backlit LCD with Digital + Bar Graph |
| Power | 4× AA Alkaline Batteries or Optional Ni-Cd Rechargeable Pack |
| Operating Temperature | −20 °C to +50 °C |
| Explosion Protection | Exibd IIB T3 |
| Dimensions | 82 × 162 × 36 mm |
| Weight | 450 g (battery-free) |
| Flow Self-Check Function | Yes |
| Auto-Ranging | Yes |
| Data Logging | Built-in (optional download via USB) |
| Origin | Italy |
|---|---|
| Type | Floor-standing Disc Stack Centrifuge |
| Model | SE03.0V |
| Max Speed | 11,000 rpm |
| Max RCF | 11,000 × g |
| Capacity | 50–1,000 L/h (batch minimum: 10 L) |
| Dimensions (W×D×H) | 670 × 455 × 880 mm |
| Power Supply | 3-phase / 380 V / 50 Hz / 1.5 kW |
| Motor Protection | IP55, Class F Insulation with Thermal Overload Protection |
| Drum Material | High-strength stainless steel (AISI 431 for spindle, precision-machined 304 stainless steel discs) |
| Casing & Frame | AISI 304 stainless steel |
| Separation Efficiency | ≤0.05% residual fat in skim milk |
| Separation Modes | Liquid–Liquid–Solid (three-phase) and Liquid–Solid (two-phase) |
| Feed/Discharge | Sanitary-grade 304 stainless steel piping with pressure gauge and micro-controlled discharge valve |
| Origin | Italy |
|---|---|
| Type | Floor-Standing Disc Stack Centrifuge |
| Model | SE03.0V |
| Max Speed | 11,000 rpm |
| Max RCF | 11,000 × g |
| Capacity | 50–1,000 L/h (batch min. 10 L) |
| Dimensions (W×D×H) | 670 × 455 × 880 mm |
| Power Supply | 3-phase / 380 V / 50 Hz / 1.5 kW |
| Motor Protection | IP55, Class F Insulation with Thermal Overload Protection |
| Drum Material | High-Strength Stainless Steel (AISI 431 for spindle, AISI 304 for housing and discs) |
| Separation Efficiency | Fat content ≤ 0.05% in skim milk |
| Separation Modes | Two-phase (liquid–solid or liquid–liquid) and three-phase (liquid–liquid–solid) |
| Compliance | Designed to meet hygienic process equipment standards for food, pharmaceutical, and biotech applications |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Seafloor-Based Monitoring System |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SM2A |
| Pricing | Available Upon Request |
| Origin | China |
|---|---|
| Manufacturer Type | Distributor |
| Model | S-Series |
| Capacity Range | HJ-400-S to HJ-1500-S |
| Pelleting Accuracy | 100% Single-Seed Encapsulation |
| Applicable Materials | Vegetable, Cereal, Cotton, Oilseed, Forage, and Forestry Seeds |
| Core Technology | German RTF (Rotational Torque Fluidization) Coating System |
| Compliance | Designed for ISO 9001-certified seed processing environments |